ANALYZER
11Pages

{{requestButtons}}

Catalog excerpts

ANALYZER - 1

ANALYZER Analyzer FRR-10 Reactive Relays Inductýve Reactor Drýver Static Contactors

Open the catalog to page 1
ANALYZER - 2

Reactive power control relays produced in compliance with CE are high-precision reactive power control relays that bring the desired value through the use of capacitors and inductive reactors, which take the Cos0 value of the plants. The device also functions as a network analyzer and allows you to view various AC parameters. The total harmonic value of all voltage and current inputs can be seen. 8-12-15-18-24 are produced gradually. Each stage of the device can be connected monophasic or triplet, capacitor or reactor. Thanks to automatic learning and automatic connection correction...

Open the catalog to page 2
ANALYZER - 3

• User friendly menu system, ease of use • Easy and fast setup • Automatically corrects faulty voltage/current connections • Automatic setup under load • Adjustable measurement period: 10-100ms • Power factor correction delay as low as 20ms • 100 MIPS, 32 bit ARM core microprocessor • Standard 12 steps • All outputs can drive static contactors • All outputs can drive 1-2-3 phase capacitors or reactors • Always exact correction with SVC outputs • 0.5% measurement accuracy, true FRR-12 Reactive Relays RMS measurements • 32 bit power measurements • Operation in low currents (3mA) • Ready for...

Open the catalog to page 3
ANALYZER - 4

• 12 and 15-stage options • Economical and high performance • Each stage capacitor or reactor Ability to connect • Each stage can be monophasic or triphasic • True RMS AC measurements, high accuracy • Very easy automatic installation • Automatic connection error correction • Electronic / mechanical counter selection • Independent compensation of each phase • All-in-one deactivation • Equal aging of contactors • Separate V-A-kW-kVAr-cos measurements of each phase • Total harmonic distortion (31 harmonics) • Genset phase input (optional) • Alarm relay output (optional) • Isolated RS-485...

Open the catalog to page 4
ANALYZER - 5

FRR 24 Reactive Relays Technicial Specifications Power Supply Input: 85 to 270V AC 50 - 60Hz nominal (± 10%) Power Consumption: < 15 VA Measurement Input Range: Voltage: 5-300V AC (L-N) 10 - 520 V AC (L-L) Current: 0.003 - 6.5 A AC Frequency: 30 - 100 Hz Accuracy: Voltage: 0.5%+1digit Current: 0.5%+1 digit Frequency: 0.2%+1 digit Power(kW,kVAr): 1.0%+2digit Power factor: 0.5%+1digit Measurement Range: CT range: 5/5A to 10'000/5A VT range: 0.1/1 to5000.0/1 kW range: 0.1 kW to 50MW Voltage burden: < 0.1VA per phase Current burden: < 0.5VA per phase Number of step outputs: 24 Relay Outputs: 5A...

Open the catalog to page 5
ANALYZER - 6

ANALYZER FRR 24 TFT Reactive Relays 5 color LCD display, 480x272 pixels 30 days long graphical compensation history User friendly menu system, ease of use Easy and fast setup Automatically corrects faulty voltage/current connections Automatic setup under load MV current measuring version available Adjustable measurement period: 10100ms Power factor correction delay as low as 20ms 120 MIPS, 32 bit ARM core microprocessor 24-18-12 step output options All outputs can drive static contactors All outputs can drive 1-2-3 phase capacitors or reactors Always exact correction with SVC outputs 0.5%...

Open the catalog to page 6
ANALYZER - 7

Technicial Specifications Power Supply Input: 170 to 275V AC 50 - 60Hz nominal (± 10%) Measurement Input Range: Voltage: 10-300VAC (L-N) 20 - 520 V AC (L-L) Current: 0.2 - 5.50 A AC Frequency: 30 - 100 Hz Accuracy: Voltage: 0.5%+1digit Current: 0.5%+1 digit Frequency: 0.5%+1 digit Power(kW,kVAr): 1.0%+2digit Power factor: 2.0%+2digit Measurement Range: CT range: 5/5A to 5000/5A VT range: 0.1/1 to5000.0/1 kW range: 0.1 kW to 50.0MW Power Consumption: <4 VA Loading: Voltage burden: < 0.1VA per phase Current burden: < 1VA per phase Relay Outputs: 5A @ 250V AC Static Contactor Outputs: 50mA...

Open the catalog to page 7
ANALYZER - 8

FPA160 Power Analyzers Technicial Specifications The FPA 160 is an advanced precision metering device offering an 3.5” size, 320x240 pixel color TFT, together with unrivalled remote monitoring capabilities over internet in a compact and low cost package. The unit itself is a web page and can be opened through any browser for remote monitoring. The central monitoring feature allows monitoring of thousands of meters from one central PC. Features • True RMS measurements, 0.2% accuracy • 3.5” TFT LCD, 320x240 pixels • Harmonic distortion display (63 harmonics) • Oscilloscope, waveform...

Open the catalog to page 8
ANALYZER - 9

FPA 140P Power Analyzers Technicial Specifications Power Supply Input: 85 to 300V AC 50 - 60Hz nominal (± 10%) 110VDC Measurement Input Range: Voltage: 10-300VAC (L-N) 20 - 520 V AC (L-L) Current: 0.2 - 5.50 A AC Frequency: 30 - 100 Hz Accuracy: Voltage: 0.5%+1digit Current: 0.5%+1 digit Frequency: 0.5%+1 digit Power(kW,kVAr): 1.0%+2digit Power factor: 0.5%+1digit Analog outputs: isolated, 4-20mA Output sensitivity: 12 bits Isolation: 1000VAC, 1 minute Measurement Range: CT range: 5/5A to 5000/5A VT range: 0.1/1 to5000.0/1 kW range: 0.1 kW to 50.0MW Power Consumption: <4 VA Voltage burden:...

Open the catalog to page 9
ANALYZER - 10

FPA 140P-AT Power Analyzers Technicial Specifications Power Supply Input: 85 to 270V AC 50 - 60Hz nominal (± 10% 88 -400VDC Measurement Input Range Voltage: 7-300VAC(L-N) 14 - 520 V AC (L-L) Current: 0.001 - 6.0 A aC Frequency: 30 - 100 Hz Accuracy: Voltage: 0.5%+1digit Current: 0.5%+1 digit • Power(kW,kVAr): 1.0%+2digit Power factor: 0.5%+1digit Withstanding: Current inputs: 100 A AC for 1 second Voltage inputs: 1300 V AC (continuous) Analog outputs: Active, 4-20mA Precision: 16bit Measurement Range: CT range: 5/5A to 25000/5A VT range: 1.0/1 to5000.0/1 kW range: 1.0 kW to 5000MW Power...

Open the catalog to page 10
ANALYZER - 11

INDUCTIVE REACTOR DRIVER SVC System is a new generation compensation system developed with the aim of being a solution to capacitor problems. The shunt reactors are triggered by thyristors at certain angles, each of which is settable in a total of 3000 steps, 1000 steps each. Modules used to do this work are called inductive load drivers. Inductive Load Drivers are designed to run three monophasic shunt reactors. These reactors, each of which is connected to a separate enclosure, are controlled in such a way that the forces are independent and provide the desired power. With these features,...

Open the catalog to page 11