Infrared(IR) LED Analyser
2Pages

{{requestButtons}}

Catalog excerpts

Infrared(IR) LED Analyser - 1

FEASA™ Infrared(IR) LED Analyser Applications Automotive - Rain Sensors - Lane Departure - Collision Avoidance - Blind Spot Detection - Number Plate Recognition - Lidar Security - Infrared Illumination Industry & Education - Interactive Whiteboards The Infrared LED Analyser measures the wavelength and relative power of Infrared LEDs' and sources. It has been designed to work in a manufacturing environment where reliability and throughput is a requirement. The OH-8IR Optical Head is used in conjunction with the Analyser to ensure stability of measurement. Choice of Glass or Plastic Optical Fiber (depending on LED under test) Operating Range 700nm to 950nm Excellent Repeatability for Wavelength & Intensity Ideal for Automotive Sensing, Security & Survellience Applications Available in 3 , 10 and 20 Channel Models Comprehensive package includes Feasa User Software and Labview Drivers. AVAILABLE INTERFACES USB 2.0 – The LED Analyser can be powered from this port. The RS232 Serial Port is easy to use. It requires the use of an external power supply and has programmable baud rates. Daisy Chain Multiple LED Analysers can be connected together using the Daisy Chain Connectors. Feasa Enterprises Ltd. Castletroy • Limerick • Ireland Telephone: + 353 61 330333 - Fax : + 353 61 330452 - Website: www.feasa.ie Registered Office: Feasa Enterprises Limited, Holland Road, National Technology Park, Castletroy, Co.Limerick, Ireland. Registered in Ireland, No. 106933. Copyright © 2011 Feasa Enterprises Limited. All rights reserved. Page 1 of 2 Rev No.11.00 - 27th March

Open the catalog to page 1
Infrared(IR) LED Analyser - 2

FEASA™ Infrared(IR) LED Analyser SPECIFICATIONS OPTICAL Total Operating Wavelength Range ACCURACY Wavelength 700nm to 750nm Wavelength 751nm to 900nm Wavelength 901nm to 950nm REPEATABILITY Wavelength Intensity ELECTRICAL Supply Voltage Supply Current PHYSICAL Dimensions of 3, 10 Channel Dimensions of 20 Channel Fiber Length Fiber Diameter, Glass Fiber Diameter, Plastic Minimum Bend Radius of Glass Fiber Minimum Bend Radius of Plastic Fiber Operating Temperature Range ORDERING INFORMATION Wavelength 700nm to 950nm Feasa 3 Channel Infrared LED Analyser, Glass Fiber Feasa 10 Channel Infrared...

Open the catalog to page 2

All Feasa Enterprises Ltd. catalogs and technical brochures

  1. LEGEND

    4 Pages

  2. Optical Head

    3 Pages