Overview: This document outlines the technical specifications and compliance details for explosion-proof electrical equipment, including earthing clamps, grounding electronic systems, acoustic signalers, and axial fans, designed for hazardous areas under international standards.
Earthing Clamps (IT25 Series):
  • Installation: Suitable for Zone 1/2 (Gases), Group II, Category 2G.
  • Mechanical Characteristics: Features nylon shock-proof insulation, elastic phosphor bronze contacts, and brass contact support. Cable entry is marine brass gland, with an earthing cable diameter of 8-11mm.
  • Applications: Used for grounding tankers during operations.
  • Compliance: Meets Directive 94/9/EC and 2014/34/EU, with EC Type-Examination Certificate CESI 05 ATEX 005. Protection degree IP66, temperature range -20°C to +55°C.
Grounding Electronic Systems (SM2021 Series):
  • Installation: Designed for Zone 1/2 (Gases), Group II, Category 2G.
  • Mechanical Characteristics: Made from marine-grade copper-free aluminum alloy with stainless steel screws.
  • Applications: Ensures grounding continuity with resistance below 20 ohms.
  • Compliance: Follows EN/IEC 60079 standards, with certificates INERIS 13 ATEX 0022X and IECEx INE 13_0070X. Protection degree IP66, temperature range -60°C to +60°C.
Acoustic Signalers (ETH9 and S2 Series):
  • Installation: Suitable for Zone 1/2 (Gases) and Zone 21/22 (Dusts), Group II, Category 2G/2D.
  • Mechanical Characteristics: Constructed from marine-grade copper-free aluminum alloy.
  • Applications: Used in environments like flares and airports for signaling.
  • Compliance: Adheres to EN/IEC 60079 standards, with certificate INERIS 15 ATEX 0012X. Protection degree IP66, temperature range -60°C to +60°C.
Axial Fans (MQ-BQ/MQ-BC Series):
  • Installation: Designed for Zone 1/2 (Gases), Group II, Category 2G.
  • Mechanical Characteristics: Includes a steel ring air conveyor and impeller mounted overhung at the motor shaft.
  • Applications: Used in aeration plants for heat and smoke removal.
  • Compliance: Follows EN 50014 and EN 50018 standards, with EC Type-Examination Certificate INERIS 05 ATEX 0025X. Protection degree IP65 or IP66, temperature range -20°C to +60°C.
Technical Specifications: Detailed specifications for explosion-proof equipment, including electric radiators and heaters, with information on voltage, frequency, power, and dimensions. Designed for hazardous areas, Group II, Category 2G 2D, complying with EN/IEC 60079 standards. Protection degrees range from IP20 to IP66.
Procedures and Installation: Suitable for hazardous areas Zone 1/2 for gases and Zone 21/22 for dusts. Equipment constructed from marine-grade copper-free aluminum and steel sheets, withstanding temperatures from -60°C to +60°C.
Standards and Compliance: Lists certificates and compliance standards, including EC Type-Examination Certificates and international certifications like IECEx, INMETRO, EAC, and Korean certification.
Recommendations and Remarks: Technical characteristics may change due to technological advancements. Confirm characteristics with the manufacturer.
Weatherproof Control Panels: Designed for safe areas with protection degree IP55, constructed from sheet steel or stainless steel, complying with CEI EN 60439-1 and CEI EN 90529 standards.
See more

Catalog excerpts

Miscellaneous-1

Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) Classification: Group II - Category 2G REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) EXECUTION PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES EAC: TC RU C-IT.ГБ08.В.01323 (-60°C ÷ +60°C) RUSSIAN MARINE CERTIFICATE (RMRS): 13.03520.315 Mechanical characteristics Haft nylon shock proof insulating elastic phosphor bronze, suitable for fastening on tank tails 8-11mm Contact support Cable entry marine brass gland Earthing cable external diameter 8-11mm (NOT SUPPLIED) APPLICATIONS IT 25… earthing clamps is used to connect tankers to ground during loading and unloading operations. Connecting the clamp to tank tail, the grounding circuits is automatically closed. Bartec Feam Catalogue

 Open the catalog to page 1
Miscellaneous-2

Explosion Proof Electrical Equipment TYPE OF CONNECTION DESCRIPTION NORMAL SPRING CLAMPING SPRING CLAMPING & MECHANICAL FIXING THIN STRUCTURE CLAMPING METAL BARREL CLAMPING ROUND SHAPED EARTHING FIXING Reference details REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. 186 I Bartec Feam Catalogue 04

 Open the catalog to page 2
Miscellaneous-3

SM2021F - SM2021IIC Electronic system to verify the grounding connection Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) Classification: Group II - Category 2G Ex Grounding electronic systems Certificate NEMA Type 4X REFERENCE STANDARDS SM2021F ELECTRONIC SYSTEM Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) EXECUTION EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-11; EN/IEC 60079-31; PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES Component: INERIS 13 ATEX 9019U IECEx: IECEx INE 13_0070X INMETRO:...

 Open the catalog to page 3
Miscellaneous-4

Explosion Proof Electrical Equipment Ex Grounding electronic systems NOT ENABLED Reference Details Reference Details INSERTION INSERTION APPLICATIONS They are used to control grounding continuity during thanks loading and unloading operations. Thanks normally arrive electrostatically loaded, and an imperfect earthing might cause fire originated by a spark in presence of gas. NOT ENABLE The earthing control system is composed of a marine grade copper free aluminium enclosure, as above described, inside fitted with the earthing ENABLE control electronic circuit SM-2001, which is normally set at...

 Open the catalog to page 4
Miscellaneous-5

Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Gruppo II - Categoria 2G 2D REFERENCE STANDARDS ACUOSTIC SIGNALERS ETH9… Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) II 2 G Ex d IIC T6 Gb II 2 D Ex tb IIIC T85°C Db EXECUTION RULES OF COMPLIANCE EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES IECEx: IECEx INE 15_0013X EAC: TC RU C-IT.ГБ08.В.01323 RUSSIAN MARINE CERTIFICATE (RMRS): 13.03520.315 ACUOSTIC SIGNALERS...

 Open the catalog to page 5
Miscellaneous-6

Explosion Proof Electrical Equipment TEMPERATURE CLASS (DUSTS) Reference Details TREZZANO S/N MILANO ITALY SERVIZIO 6 AVVIAM/ORA S4-60% 6 STARTS PER HOUR DUTY TREZZANO S/N SIRENA MILANO ITALY 0575 SERVIZIO 6 AVVIAM/ORA SYREN Ta-20°C/+55°C S4-60% 6 STARTS PER HOUR DUTY SIRENA 0575 SYREN NON APRIRE QUANDO PUO' ESSERE PRESENTE UNA ATMOSFERA ESPLOSIVA DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT NON APRIRE QUANDO PUO' ESSERE PRESENTE UNA ATMOSFERA ESPLOSIVA DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT REMARK: Due to the development of the national and international specifications...

 Open the catalog to page 6
Miscellaneous-7

MQ-BQ / MQ-BC Axial fan low pressure Explosion Proof Electrical Equipment MQ-BQ / MQ-BC Installation: hazardous areas - Zone 1 / 2 (Gases) Classification: Group II - Category 2G REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) EXECUTION PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES Mechanical characteristics Air conveyor mounted overhung at the mototr shaft by immersion in bath electrophoresis and subsequent firing in a kiln Applications For aeration plants where it is necessary to remove heat, smoke, stale air...

 Open the catalog to page 7
Miscellaneous-8

Technical Features Explosion Proof Electrical Equipment CODE TURNS/min. VOLTAGE CODE TURNS/min. VOLTAGE Reference Details Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. 1921 Bartec Feam Catalogue 04

 Open the catalog to page 8
Miscellaneous-9

READ / RERAC Flameproof electric radiators industrial electric heaters Explosion Proof Electrical Equipment READ / RERAC Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) - Safe Areas Classification: Group II - Category 2G 2D RERAC READ REFERENCE STANDARDS FLAME PROOF ELECTRIC RADIATORS - READ (SWITCH) II 2 G Ex d IIC T6 Gb II 2 D Ex tb IIIC T85°C Db EXECUTION RULES OF COMPLIANCE EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES IECEx: IECEx INE 11.0033X INMETRO: CEPEL 13.2255X EAC: TC RU C-IT.ГБ08.В.01323...

 Open the catalog to page 9
Miscellaneous-10

READ / RERAC Technical Features Explosion Proof Electrical Equipment CODE A [mm] B[mm] C[mm] D[mm] E[mm] WEIGHT [Kg] DETAIL CONSTRUCTION FEATURES: Electric heater, oil field, movable on pivoting wheels or to be fixed by special supports on the floor or to the wall. Two electric armoured resistances unit provided with incorporated thermal circuit breaker located inside one. Resistance thermal exchange: 2W/sgcm Control gear box containing a three positions change over swich: 0 - 50% -100% power. Adjustable thermostat. Certified cable gland for a feeding armoured 2 Mt. cable 3x2.5sgmm Heating system...

 Open the catalog to page 10
Miscellaneous-11

WEATHERPROOF CONTROL PANELS Explosion Proof Electrical Equipment Weatherproof Control Panels WEATHERPROOF CONTROL PANELS Installation: Safe area Classification: IP55 REFERENCE STANDARDS ELECTRICAL PANEL CEI / IEC EXECUTION INDUSTRIAL WATERPROOF TEMPERATURA AMBIENTE PROTECTION DEGREE Mechanical characteristics Framework And Panel 15-20/10 thik sheet steel with galvanic or sendzimir treatment tempered glass (5mm thickness) complete with silicon rubber gasket stainless steel Mechanical characteristics RERAC Maximum rating Inslutating voltage Test voltage Short circuit withstand strenght on plate...

 Open the catalog to page 11

All F.E.A.M. s.r.l. catalogs and technical brochures

  1. Enclosures

    50  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.