Overview: This document is a technical catalogue from Bartec Feam, focusing on explosion-proof electrical equipment, specifically switchracks and enclosures for hazardous areas. It includes specifications, standards, and installation guidelines.
Switchracks:
  • Design and Installation: Custom-designed for hazardous areas (Zone 1/2 for gases, Zone 21/22 for dusts), made from marine-grade aluminum or stainless steel. Optional accessories include stainless steel fittings and various painting options.
  • Standards and Compliance: Compliant with Directive 94/9/EC and Directive 2014/34/EU, with protection ratings such as Ex db IIB+H2 T6…T3 and Ex tb IIIC T85°C…T150°C. Adheres to EN/IEC 60079 standards with a protection degree of IP66.
  • Testing and Quality Control: Includes visual, dimensional, and functional tests. Customers can request inspections and quality control documentation.
  • Ordering Information: Requires details like area classification, applicable standards, wiring diagrams, and dimensions. Customer approval is needed for manufacturing drawings.
EJB Enclosures:
  • Mechanical Characteristics: Made from copper-free aluminum or stainless steel, with options for epoxy painting and additional features like glass windows and drain valves.
  • Standards and Compliance: Similar compliance as switchracks, with additional certifications like IECEx, INMETRO, and RINA. They have a protection degree of IP66 and are suitable for ambient temperatures from -60°C to +60°C.
  • Technical Features: Detailed dimensions and weight specifications for various models, along with drilling layouts and terminal capacities.
General Notes: Emphasizes the importance of adhering to evolving national and international specifications and technology advancements. Highlights Bartec Feam's responsibility in ensuring quality and compliance.
Explosion Proof Electrical Equipment Overview: Provides detailed specifications and technical features of explosion-proof electrical enclosures for hazardous locations, classified according to international standards.
Specifications: Enclosures made from marine-grade copper-free aluminum or stainless steel, compliant with Directive 94/9/EC and Directive 2014/34/EU, and standards such as EN/IEC 60079. Protection degree is IP66, suitable for temperatures from -60°C to +80°C.
Technical Features: Lists various models like EJB and GUB series, with dimensions and terminal capacities. Equipped with internal and external grounding provisions and supply connections.
Installation and Compliance: Suitable for hazardous areas (Zone 1/2 for gases, Zone 21/22 for dusts), certified for Class I, Groups B, C, D; Class II, Groups E, F, G; and Class III locations. Details on drilling layout and allowed entries.
Additional Features: Optional accessories include epoxy painting, O-ring gaskets, glass windows, and drain valves. Technical characteristics subject to confirmation due to evolving specifications.
Transmission Devices: Focuses on devices with padlockable handles for MCBs and MCCBs, detailing parts, dimensions, and compliance with international standards.
Specifications: Part numbers include 2040.00578, EFI-GUB1, 2040.00258, and EFISL, with specific dimensions and features. Materials include marine-grade aluminum and tempered glass.
Standards and Compliance: Complies with Directive 94/9/EC and Directive 2014/34/EU, with a protection degree of IP66, suitable for hazardous areas. Certificates include EC Type-Examination Certificate INERIS 02 ATEX 0069X, IECEx, EAC, and Russian Marine Certificate.
Mechanical Characteristics: Body and cover made from marine-grade aluminum, with NBR O-Ring sealing. Optional accessories include epoxy painting and stainless steel valves.
Technical Features: Various enclosure codes with specific dimensions and weights, drilling layouts, and terminal capacities.
Recommendations: Ensure compliance with specified standards for installation in hazardous areas. Consider optional accessories for enhanced protection and functionality.
Specifications: Compliance and certification details for explosion-proof equipment, with execution standards and protection degree of IP66, suitable for temperatures from -60°C to +60°C.
Certificates: Holds several certificates, including EC Type-Examination Certificate INERIS 02 ATEX 0067X, IECEx, INMETRO, EAC, RINA, and Russian Marine Certificate.
Enclosures: Details specifications for ES junction boxes, classified as IP66 waterproof enclosures, made from marine-grade aluminum with optional accessories.
Technical Features: Provides a table of enclosure dimensions, drilling areas, and allowed entries, with indicative terminal quantities.
Remarks: Notes that technical characteristics are binding only upon confirmation due to evolving specifications and technology.
See more

Catalog excerpts

Enclosures-1

SWITCHRACKS Custom designed, switchracks, panel boards, motor starters Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) ( II 2 G Ex d IIC T6...T3 II 2(1) GD Ex d [ia/ib IIA or IIB or IIC Ga] IIC T6...T3 II 2 D Ex tb IIIC T85°C...T200°C II 2 D Ex tb [ia Da/ib] IIIC T85°C II 2 G Ex d e ia/ib ia mb IIC T6, T5 or T4 Gb II 2 D Ex tb IIIC T85°C or T100°C Db RULES OF COMPLIANCE EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-11; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES IECEx INMETRO EAC RINA RUSSIAN MARINE CERTIFICATE (RMRS) UL NEC 505 NEC - NEMA 4, 7, 9 Class I - Groups B, C, e D Class II - Groups E, F, e G Class III INSTALLATION PROTECTION PROTECTION DEGREE AMBIENT TEMPERATURE CERTIFICATION AND COMPLIANCES -20°C ÷ +40°C UL Standard 1203 - 4° Ed. (15 Sett. 2006) Explosion-Proof / Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations Mechanical characteristics Boxes Painting Screws Gaskets Pipes and fittings Supporting rack marine grade copper free aluminum - stainless steel AISI 316L external epoxy powders grey RAL-9006 colour (standard) external stainless steel silicon rubber galvanized steel (standard) - stainless steel (optional) hot dip galvanized steel - stainless steel On request accessories: • Stainless steel pipes and fittings • Galvanized steel epoxy painted supporting rack • Stainless steel supporting rack • Internal anticondensate painting orange RAL-2004 • External colours different from standard

 Open the catalog to page 1
Enclosures-2

Switchracks panel boards - general information Explosion Proof Electrical Equipment Description: “SWITCH-RACK” is a word usually adopted to indicate an ensemble of control units, signaling units, motor starters, switching units, and so on. Switch-racks are mechanically assembled on robust frame with various fixing solutions (ground, wall, etc.), electrically wired up on purpose. BARTEC-FEAM since over 50 years, designs and manufacturers switch-racks according to its own diagram or according to customer’s specifications, in full compliance with European CENELEC standards. INFORMATIONS: Test and...

 Open the catalog to page 2
Enclosures-3

Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D Certificate NEMA Type 4X REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) EXECUTION EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-11; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES Component: INERIS 13 ATEX 9019U IECEx: IECEx INE 13_0070X INMETRO: CEPEL 12.2139 EAC: TC RU C-IT.ГБ08.В.01499 RINA: ELE18111CS_012 RUSSIAN MARINE CERTIFICATE (RMRS): 13.03518.315...

 Open the catalog to page 3
Enclosures-4

Explosion Proof Electrical Equipment Reference details EJB Glass windows on cover ENCLOSURE CODE WINDOW CODE 98 I Bartec Feam Catalogue 04

 Open the catalog to page 4
Enclosures-5

Explosion Proof Electrical Equipment EJB Glass windows on cover Reference details Reference details CUSTODIA tipo ENCLOSURE type Via M. Pagano, 3 I-20090 Trezzano s/N ITALY www.feam-ex.com NON APRIRE SOTTO TENSIONE DO NOT OPEN WHILE ENERGIZED Ad ogni apertura del coperchio ripristinare il grasso ai siliconi. accertarsi che le valvole di respirazione e drenaggio siano sempre chiuse Renew silicone grease every tyme cover is opened. and make sure that the drain and breather valves are always closed. EJB Indicative quantity of terminals and relevant section CODE EJB Body and cover enclosures drilling...

 Open the catalog to page 5
Enclosures-6

EJB Body and cover enclosures drilling layout Reference details Explosion Proof Electrical Equipment EJB Threads comparation table WALL DRILLING AREA A Max allowed quantity of push button and pilot light ENCLOSURE CODE COVER DRILLING AREA Reference details REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confi

 Open the catalog to page 6
Enclosures-7

Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D Certificate NEMA Type 4X REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) (II 2 G) Ex db IIB+H2 T6…T3 (II 2 G) Ex db [ia/ib] IIB+H2 T6…T3 (II 2 D) Ex tb IIIC T85°C…T150°C EXECUTION RULES OF COMPLIANCE EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-11; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES Component: INERIS 13 ATEX 9019U IECEx: IECEx INE 13_0070X...

 Open the catalog to page 7
Enclosures-8

Explosion Proof Electrical Equipment Reference details EJB INX Indicative quantity of terminals and relevant section SEZ. 2,5 [sq/mm] 102 I Bartec Feam Catalogue 04

 Open the catalog to page 8
Enclosures-9

Explosion Proof Electrical Equipment EJB INX Glass Windows on Cover ENCLOSURE CODE WINDOW CODE Reference details Reference details CUSTODIA tipo ENCLOSURE type Via M. Pagano, 3 I-20090 Trezzano s/N ITALY www.feam-ex.com NON APRIRE SOTTO TENSIONE DO NOT OPEN WHILE ENERGIZED Ad ogni apertura del coperchio ripristinare il grasso ai siliconi. accertarsi che le valvole di respirazione e drenaggio siano sempre chiuse Renew silicone grease every tyme cover is opened. and make sure that the drain and breather valves are always closed. EJB INX Body and cover enclosures drilling layout ENCLOSURE CODE EJB-11...

 Open the catalog to page 9
Enclosures-10

EJB INX Body and cover enclosures drilling layout Max allowed q.ty of push button and pilot light 120x120 COVER DRILLING AREA Reference details ENCLOSURE CODE Explosion Proof Electrical Equipment EJB INX Threads comparation table SIZE REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confi