Overview: The flox[on] J is a mass flow controller designed for large gas flows ranging from 1500 to 7000 Nl/min at pressures up to 16 bar. It utilizes thermal anemometry for gas flow measurement and features a pressure-compensated proportional valve for regulation, ensuring performance independent of pressure fluctuations. Manufactured with Swiss precision, it is maintenance-free, easy to operate, and safe.
Specifications:
  • Maximum Flow: 7000 Nl/min
  • Minimum Flow: 1500 Nl/min
  • Maximum Operating Pressure: 16 bar
  • Regulation Ratio: 1:40
  • Accuracy: ±3%
  • Step Response: 1 to 5 seconds
  • Operating Temperature: -10 to +60°C
Materials:
  • Housing: Aluminium
  • Flange Connector: Aluminium
  • Valve: Brass
  • Sinter Filter: Brass, 50 µ
  • Sealing: NBR
Electrical Equipment:
  • Connection Voltage: 24 V DC ± 15%
  • Capacity: Max 20 W
  • Signal Set/Real: 4-20 mA
Installation and Maintenance: The device should be installed horizontally to avoid faulty measurements. It is maintenance-free and guaranteed for two years. Incorrect wiring can damage electronics, and liquids or particulate matter can impair performance.
Calibration and Gas Correction: The measuring cell is calibrated with atmospheric air, with correction factors available for other gases. Direct calibration with specific gases is possible upon request.
Important Notices: The flox[on] J is intended for gas use only. Liquids and gas impurities can damage the device. For any issues, contact the service center.
See more

Catalog excerpts

Manual flox[on] J-1

FCTechnik M ass F low Cont ro ller

 Open the catalog to page 1
Manual flox[on] J-2

P e r f ect C o n t rol The flox[on] J is designed for very large gas flows between 1500 and 7000 Nlmin-1 under operating pressures of up to 16 bar. The measurement of the gas flow is based on principles of thermal anemometry. The mass flow is regulated by means of a technically sophisticated pressure-compensated proportional valve, which operates independently of pressure fluctuations at the in- and outlets. Manufactured with Swiss precision, these devices have a long operating life expectancy, even under the harshest industrial conditions. They are also maintenance-free, easy to operate and...

 Open the catalog to page 2
Manual flox[on] J-3

3 Outlet flange with thread connection 4 Inlet flange with thread connection 5 Micro-processor board 6 M8 Power supply 7 M12 Analog connector 8 LED operating mode 9 Measuring cell 10 Filter

 Open the catalog to page 3
Manual flox[on] J-4

Im porta n t data data Minimum flow Maximum flow Maximum operating pressure Operating temperature Regulation ratio Real Value Real Value Connection voltage Flange connector Connection analog Sinter filter Signal Set/Real Bypass signal

 Open the catalog to page 4
Manual flox[on] J-5

connection assignment 2 LED d i splay Ready In operation Fully open Fault

 Open the catalog to page 5
Manual flox[on] J-6

Gas e s a n d ca l i b rati on Before delivery, the measuring cell in every flox[on] J is calibrated with atmospheric air. There are correction factors for applications using other gases. In individual cases, if desired by the client, the calibration can be made directly with the specific gas intended for use. If a mixed gas such as air or natural gas is used, it should be noted that a change in the composition of the gas can occur during operation. In such cases, and for all other questions about calibration, please contact our service center (see back page of this manual). The measuring cell...

 Open the catalog to page 6
Manual flox[on] J-7

im portant Notic e s Not e s on insta llati o n Warning notices To ensure trouble-free operation, the flox[on] J should be installed in a horizontal position. If installed vertically, the device could produce faulty measurements under certain conditions. When delivered, the flox[on] J comes in secure transport packaging. It can be stored under dry conditions for up to two years before installation. ● The flox[on] J is intended solely for use The flox[on] J is maintenance-free even under harsh conditions. In case of a fault or failure of the measuring cell, please contact the service center. The...

 Open the catalog to page 7