The document provides a detailed overview of the mass flow controllers offered by FC Technik, specifically the flox[on] series, including models B, S, S500, and J. These devices are designed for precise gas flow regulation and are maintenance-free with no recalibration required during their lifetime.

Specifications
  • Flow Range: Maximum flow rates range from 200 to 7000 Nl/min, depending on the model.
  • Pressure: Maximum operating pressure is 16 bar for all models.
  • Regulation Ratio: Varies from 1:30 to 1:500.
  • Accuracy: All models have a device accuracy of 1% Full Scale.
  • Response Time: Step response time ranges from 1.5 to 7 seconds.
  • Operating Temperature: All models operate between -10°C to +60°C.

Equipment and Connectivity
  • Power Supply: 24 VDC with ±15% tolerance.
  • Connections: M8 power supply and M12 analog connections.
  • Display: LED display for operating mode.
  • Software: Includes "Regulation Tuning" software for device configuration.

Materials and Construction
  • Housing and Valve Parts: Made from aluminium, brass, and stainless steel, depending on the model.
  • Sealing: NBR and FPM materials used for sealing.
  • Protection: IP54 or IP65 protection rating.

Operation and Calibration
  • Gases: Compatible with compressed air, N2, Ar, CO2, H2, CH4, and O2.
  • Calibration: Devices are pre-calibrated with atmospheric air, with correction factors available for other gases. Direct calibration with specific gases is available upon request.

Gas Correction Factors
  • Hydrogen (H2): 0.7
  • Argon (Ar): 0.95
  • Nitrogen (N2): 1.0
  • Oxygen (O2): 1.0
  • Methane (CH4): 1.1
  • Carbon Dioxide (CO2): 1.35

Contact Information
FC Technik AG, St. Gallerstrasse 340, CH-8409 Winterthur, Tel. +41 (0) 52 238 01 75, Fax +41 (0) 52 238 01 77, www.fc-technik.com, [email protected]
See more

Catalog excerpts

FCTechnik-1

product range mass flow controller

 Open the catalog to page 1
FCTechnik-2

Maintanance free product features PRODUCT FEATuREs Maximum flow Minimum flow Maximum operating pressure Regualtion ratio Device Accuracy Step response time (10% - 90%) Operating temperature Calibration media (see also chapter calibration) FLox[oN] J standard: comp. air Calibration media Connection M8 power supply LED display operating mode Software “Regulation Tuning Connection M8 power supply LED display operating mode Software “Regulation Tuning Inlet / Outlet Port GAS FLOW OF THE FLOX[ON] SERIES FLox[oN]s Before delivery, the measuring cell in every flox[on] is calibrated with atmospheric...

 Open the catalog to page 2
FCTechnik-3

FC Technik AG St. Gallerstrasse 340 CH-8409 Winterthur www.fc-technik.com [email protected]

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.