Datasheet flox[on] B new
4Pages

{{requestButtons}}

Catalog excerpts

Datasheet flox[on] B new - 1

DATA 2.0 SHEET floxEon] B | April 2019 | Page 1 MASS FLOW CONTROLLER Proportional valve Outlet flange with thread connection Inlet flange with thread connection M8 Power supply Ml 2 Connector signal interface Micro USB port 3 LEDs operating mode backsight of flox[on] B economy and extended frontsight of flox[on] B stainless steel CONNECTiON ASSiGNMENT M8 POWER SUPPLY USB PORT The USB Port connects the flox]on] B with a PC. LED AND OPERATiNG MODUS Power Set Value Set Value Real value Real value Dig. Input All information is provided in best conscience. Some clients may desire certain modifications which lead to results other than those found in this manual.

Open the catalog to page 1
Datasheet flox[on] B new - 2

flox[on]B DATA SHEET flox[on] B | April 2019 | Page 2 MASS FLOW CONTROLLER AVAILABLE MODIFICATIONS OF FLOX[ON] B The measurement of all flox[on] B mass flow controller is based on the principle of thermal anemometry. The measuring cell is located in a bypass. The measurement of the gas flow is temperature and pressure compensated. The regulation of the flow will be made by a pressure compensated proportional valve which is insensitive to incoming pressure (0-16 bar) as well as outflow pressure. The valve is controlled by a solenoid and can be opened fully under any pressure conditions. All...

Open the catalog to page 2
Datasheet flox[on] B new - 3

flox[on]B DATA SHEET flox[on] B | April 2019 | Page 3 MASS FLOW CONTROLLER You can get the software by asking for it (info@fc-technik.ch). It requires Windows. The software enables to operate the flox[on] B without any other process control. The software allows to: • to get all information about the device, • to see and to manipulate the calibration data, • to have a look at the actual operation and to overwrite the set point. Though the measuring cell does not require a recalibration for the rest of its lifetime it might be possible in very special processes to manipulate the calibration...

Open the catalog to page 3
Datasheet flox[on] B new - 4

DATA SHEET flox[on] B | April 2019 | Page 4 MASS FLOW CONTROLLER IMPORTANT NOTICES To ensure trouble-free operation, the flox[on] B should be installed in a horizontal position. If installed vertically, the device could produce faulty measurements under certain conditions. The flox[on] B is maintenance-free even under harsh conditions. In case of a fault or failure of the measuring cell, please contact the service center. When delivered, the flox[on] B comes in secure transport packaging. It can be stored under dry conditions for up to two years before installation. The flox[on] B is...

Open the catalog to page 4

All FCTechnik - Gas Control Systems - flox[on] MFC catalogs and technical brochures

  1. flox[on] J

    2 Pages

Archived catalogs

  1. FCTechnik

    3 Pages

  2. Gas Control

    3 Pages

  3. flox[on] S

    2 Pages

  4. flox[on] B

    2 Pages