Overview: The flox[on] B is a mass flow controller designed by FCTechnik, utilizing thermal anemometry for gas flow measurement. It features a pressure-compensated proportional valve and a high-performance microcontroller.
Specifications:
  • Maximum Flow: 200-250 Nl/min
  • Minimum Flow: 0.5 Nl/min
  • Maximum Operating Pressure: 16 bar
  • Regulation Ratio: 1:30 to 1:50
  • Device Accuracy: 1% Full Scale
  • Step Response Time: 1.5 seconds or less
  • Operating Temperature: -10 to +60°C
Product Versions:
  • Economy: Suitable for standard gases like compressed air, nitrogen, and argon.
  • Extended: Handles gases such as hydrogen, methane, and oxygen.
  • Stainless Steel: Ideal for applications in the food industry, free of brass components.
Connections:
  • M8 Power Supply: 24 VDC, 0 V, PE Ground
  • M12 Analog Connector: Set and Real Value 4-20 mA, Digital Input 24 VDC
  • USB Port: Connects to PC for data exchange and device regulation tuning.
Calibration: The device is pre-calibrated with atmospheric air. Calibration can be adjusted for specific gases if required. The measuring cell does not require recalibration for its lifetime.
Installation and Maintenance: The flox[on] B should be installed horizontally to avoid faulty measurements. It is maintenance-free but should be protected from liquids and particulate matter.
Guarantee: The product comes with a 2-year guarantee. Incorrect wiring can damage the electronics.
Contact Information: FC Technik AG, St. Gallerstrasse 340, CH-8409 Winterthur, Tel. +41 (0) 52 238 01 75, [email protected]
See more

Catalog excerpts

Datasheet flox[on] B new-1

DATA 2.0 SHEET floxEon] B | April 2019 | Page 1 MASS FLOW CONTROLLER Proportional valve Outlet flange with thread connection Inlet flange with thread connection M8 Power supply Ml 2 Connector signal interface Micro USB port 3 LEDs operating mode backsight of flox[on] B economy and extended frontsight of flox[on] B stainless steel CONNECTiON ASSiGNMENT M8 POWER SUPPLY USB PORT The USB Port connects the flox]on] B with a PC. LED AND OPERATiNG MODUS Power Set Value Set Value Real value Real value Dig. Input All information is provided in best conscience. Some clients may desire certain modifications which lead to results other than those found in this manual.

 Open the catalog to page 1
Datasheet flox[on] B new-2

flox[on]B DATA SHEET flox[on] B | April 2019 | Page 2 MASS FLOW CONTROLLER AVAILABLE MODIFICATIONS OF FLOX[ON] B The measurement of all flox[on] B mass flow controller is based on the principle of thermal anemometry. The measuring cell is located in a bypass. The measurement of the gas flow is temperature and pressure compensated. The regulation of the flow will be made by a pressure compensated proportional valve which is insensitive to incoming pressure (0-16 bar) as well as outflow pressure. The valve is controlled by a solenoid and can be opened fully under any pressure conditions. All flox[on]...

 Open the catalog to page 2
Datasheet flox[on] B new-3

flox[on]B DATA SHEET flox[on] B | April 2019 | Page 3 MASS FLOW CONTROLLER You can get the software by asking for it ([email protected]). It requires Windows. The software enables to operate the flox[on] B without any other process control. The software allows to: • to get all information about the device, • to see and to manipulate the calibration data, • to have a look at the actual operation and to overwrite the set point. Though the measuring cell does not require a recalibration for the rest of its lifetime it might be possible in very special processes to manipulate the calibration (here...

 Open the catalog to page 3
Datasheet flox[on] B new-4

DATA SHEET flox[on] B | April 2019 | Page 4 MASS FLOW CONTROLLER IMPORTANT NOTICES To ensure trouble-free operation, the flox[on] B should be installed in a horizontal position. If installed vertically, the device could produce faulty measurements under certain conditions. The flox[on] B is maintenance-free even under harsh conditions. In case of a fault or failure of the measuring cell, please contact the service center. When delivered, the flox[on] B comes in secure transport packaging. It can be stored under dry conditions for up to two years before installation. The flox[on] B is intended...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.