video corpo

T-SPOT
5Pages

{{requestButtons}}

Catalog excerpts

T-SPOT - 1

Adjustable nozzle diffuser T-SPOT Description Nozzle diffuser for wall mounting. The possibility of directing the launch in all directions (within an angle of ± 30 °), enables this solution very adaptable to different conditioning needs, both summer and winter. It is commonly used when horizontal throw are needed even at great distance : conference rooms, exhibition areas, sports arenas, but, thanks to the content levels of noise, even theaters, cinemas and auditoriums. The modern design with minimal protrusion, available in different finishes and no screws in sight, produce serial geometries of striking appearance. Construction Natural aluminum painted. Felt gasket. Finish Metallinox (T-SPOT), gloss white RAL 9010 (T-SPOT W), powder-coated polyester type. Optional two-colour (eg. black flanged cover and white sphere) also with RAL colours on specification. T-SPOT Specifications Diffuser nozzle for long throws. Adjustable sphere in all directions (± 30 °). Wall mounting with screws out of sight (cover flange). Construction in painted aluminum, with gaskets made of felt. qv air flow aP pressure drop X05 isothermic horizontal throw (isotachy 0,2 m/s) Lwa sound power level (ref. 10-12 W) F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - fcr@fcr.it

Open the catalog to page 1
T-SPOT - 2

Adjustable nozzle diffuser qv hmin hMax imin flow range recommended Minimum installation height Maximum installation height Minimum recomended interaxis 1 Select the size Gr of the nozzle according to the air volume requested qv. height installation distance between the wall where the nozzle is installed and the point of interest distance between the nozzles air flow for single nozzle coordinate along the trajectory of the launch measured speed at the point of the trajectory with coordinate s (center of the front) inclination of the nozzle axis vertical deviation of the launch (with Dt = ±...

Open the catalog to page 2
T-SPOT - 3

Adjustable nozzle diffuser F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - fcr@fcr.it

Open the catalog to page 3
T-SPOT - 4

Adjustable nozzle diffuser F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - fcr@fcr.it

Open the catalog to page 4
T-SPOT - 5

Adjustable nozzle diffuser Mounting scheme In the case of direct mounting on visible duct , we recommend you make a detachment diameter close to ∅ D and length ≥ 2 E. It is also recommended to size the main duct generously in order to optimize the pressure distribution between the nozzles and contain noise.   Air flow calculation Due to the contraction of the vein, the area Ak differs from geometrical one measured on the mouth of the nozzle. You must use hot-wire anemometers taking care to position the probe as shown and orient the “window” against the flow. You must measure the...

Open the catalog to page 5

All F.C.R. SPA catalogs and technical brochures

  1. FCROLL

    1 Pages

  2. UNI-BOX

    1 Pages

  3. MULTI-PAK 3V

    2 Pages

  4. TRZT

    1 Pages

  5. LF

    7 Pages

  6. LC

    10 Pages

  7. DMAN

    3 Pages

  8. UFO-EH

    4 Pages

  9. LD / LD-Q

    7 Pages

  10. DMF

    3 Pages

  11. UFO-C

    3 Pages

  12. UFO-EHC

    3 Pages

  13. UFO-N

    3 Pages

  14. CIRCLE LINE

    3 Pages

  15. DRA

    3 Pages

  16. DKE

    3 Pages

  17. BPA 20

    5 Pages

  18. BPA 20 Box

    3 Pages

  19. BZC

    4 Pages

  20. LPB 10

    4 Pages

  21. DES

    3 Pages

  22. MQZ

    1 Pages

  23. MCZ

    1 Pages

  24. KCA

    1 Pages

  25. FCA

    1 Pages

  26. CPT

    1 Pages

  27. MMX

    1 Pages

  28. GLC

    1 Pages

  29. GLZ

    1 Pages

  30. WLZ

    1 Pages

  31. MTS-8

    1 Pages

  32. MTS-9

    1 Pages

  33. MAT-FLO

    1 Pages

  34. MAT-GLAS

    1 Pages

  35. BNT

    1 Pages