1. Catalogs
  2. FAULHABER Drive Systems
  3. The magazine with drive

The magazine with drive

The magazine with drive
1 / 28 PagesView full catalog

The magazine with drive

Product catalog summary
Introduction
The FAULHABER motion magazine highlights the significant role of FAULHABER drive systems across various sectors, including medical diagnostics, optics, photonics, and aerospace. It also introduces new innovations in drive technology.
News
  • Award Recognition: FAULHABER has been recognized as the first "Preferred Technology Partner" by Heidelberger Druckmaschinen AG for its technological innovations.
  • Delicate Touch and Integrated Referencing: The new magnetic multiturn AEMT-12/16 L absolute encoder, when paired with brushless DC servomotors, offers precise angle information and efficient operation.
Innovation
  • Applications? Step into the Ring: A new direct drive with a large central opening is introduced, suitable for demanding applications in optics, photonics, and robotics. The DM66200H stepper motor series features a 40 mm diameter hollow shaft, balancing speed and torque.
Medical & Laboratory Equipment
  • A Head Start Saves Lives: FAULHABER drives are essential in medical diagnostics, enabling quick and reliable analyses, crucial for diagnosing infectious diseases like COVID-19 and influenza.
Optics & Photonics
  • Hotspot: FAULHABER motors are used in thermal imaging cameras for precise images and measurements, important for infection detection at airports and train stations.
  • LightRevolution: The Light Revolution System uses FAULHABER precision motors to create unique images by illuminating objects from a circular path.
Aerospace
  • Surfing Back to Earth: Linear motors from FAULHABER are used for dynamic stabilization of test capsules in aerospace technology.
Conclusion
The magazine emphasizes FAULHABER's commitment to innovation and excellence in drive technology, impacting various industries and applications.
Point-of-Care (PoC) Testing and Microfluidics: PoC devices, crucial for COVID-19 detection, utilize PCR tests and are nearly fully automated. FAULHABER micro DC motors are recommended for their compact size and efficiency.
Automation in Large-Scale Laboratories: Automation enhances reliability and throughput in in-vitro diagnostics, requiring precise drive systems. FAULHABER's micro DC motors and encoders are suitable for these tasks.
Thermal Imaging for Mass Temperature Monitoring: Thermal imaging cameras, supported by FAULHABER motors, are used for fast temperature monitoring, crucial for detecting COVID-19 cases at airports.
Applications of Thermography: Thermography is used in quality control, safety technology, and atmospheric research, detecting temperature leaks and monitoring manufacturing processes.
Aerospace Applications: The HADES project uses FAULHABER linear motors for the dynamic stabilization of space capsules during re-entry.
Stabilization of Space Capsules: The HADES project aims to prevent capsule disorientation using center-of-gravity displacement with FAULHABER linear DC servo motors.
HADES Capsule Flight Phases: The capsule undergoes several phases, with motors maintaining orientation throughout.
Light Revolution System in Photography: The system uses rotating LED lights for unique photographic effects, with FAULHABER motors ensuring smooth movement.
Applications and Testing: The Light Revolution System is tested for creating 3D models and facilitating global data exchange.
Upcoming Topics: The next issue will explore CNC lathes and milling machines, focusing on high mix and high volume production with FAULHABER's servo-controlled gripper jaws.
See more

Catalog excerpts

The magazine with drive-1

THE MAGAZINE WITH DRIVE APPLICATIONS? STEP INTO THE RING.

 Open the catalog to page 1
The magazine with drive-2

Award FAULHABER first “Preferred Technology Partner” of Heidelberger Druckmaschinen AG NEWS Delicate touch and integrated referencing In combination with brushless DC-servomotors, the new magnetic multiturn AEMT-12/16 L absolute encoder delivers absolute angle information Applications? Step into the ring. A new direct drive now offers a promising alternative for demanding applications M E D I C A L & L A B O R AT O RY A head start saves lives Reliable analyses in a large-scale laboratory or at the point of care (PoC) OPTICS & PHOTONICS Hotspot Precise images and measurement values. Motors from...

 Open the catalog to page 2
The magazine with drive-3

Dear Readers, The corona pandemic has clearly demonstrated to the whole world just what a highly contagious virus can do. Tourists and travellers have unintentionally contributed to the spread of the disease. Detecting infected persons on arrival at airports or train stations is key in preventing a potential chain of infection. Thermal imaging Publisher / Editor: DR. FRITZ FAULHABER GMBH & CO. KG Schönaich · Germany Phone: +49 (0)70 31/638-0 Fax: +49 (0)70 31/638-100 E-Mail: [email protected] www.faulhaber.com cameras make a decisive contribution here. Drives from FAULHABER help these cameras...

 Open the catalog to page 3
The magazine with drive-4

AWARD: FAULHABER IS FIRST “PREFERRED TECHNOLOGY PARTNER” OF HEIDELBERGER DRUCKMASCHINEN AG Heidelberger Druckmaschinen AG has been a reliable partner with great innovative strength for the global printing industry. The company's mission is to shape the digital future of the sector. For the extraordinary technological achievements and innovative support on the way to achieving this goal, Heidelberger has now designated FAULHABER as “Preferred Technology Partner.” FAULHABER is especially happy about this sign of recognition as it is the first time that Heidelberger Druckmaschinen AG has granted...

 Open the catalog to page 4
The magazine with drive-5

the “Electric Drives” product group. Various performance indicators play a role in the evaluation of this category. These include the zero-error rate in product and process quality, continuous improvement, a cooperative partnership and reliability with regard to logistics. “FAULHABER was able to convince us in all of these aspects,” commented Helmut Braun, head of Quality Assurance/Electronics Procurement at Heidelberger. Sebastian Huber, Senior Manager Purchasing: “FAULHABER has already in the past proven its outstanding performance in the collaboration with Heidelberger which, in each of the...

 Open the catalog to page 5
The magazine with drive-6

APPLICATIONS? STEP INTO THE RING. Many applications require drive solutions that have a central opening through which, e.g., light, cables or parts of the application can be guided. Examples of this can be found in optics and photonics for laser steering systems or in automation and robotics for semiconductor handling systems. Until now, conventional systems always resulted in compromises here. The apertures of the hollow shafts were often quite small, the drives slow, heavy or the mechanical integration required a great deal of work. But now, a new direct drive offers a promising alternative,...

 Open the catalog to page 6
The magazine with drive-8

APPLICATIONS? STEP INTO THE RING. Laser beam control There are many drive technologies and solutions available that are generally suitable in cases where a central opening is needed. In practical use, however, each has its own disadvantages. With classically constructed motors, for example, the diameter of the hollow shaft is usually limited to approximately 10 to 12 mm on account of the necessary copper filling factor or magnet yoke. Due to their multi-pole design, torque motors do permit larger openings, but cannot achieve high speeds due to their large moving mass. In addition, they are relatively...

 Open the catalog to page 8
The magazine with drive-9

New approach – new possibilities For the new DM66200H stepper motor series, FAULHABER has developed an entirely new drive solution, specially designed for applications requiring a large central opening. With a total diameter of 66 mm, it offers a very large hollow shaft inner diameter of 40 mm. And it is only 24 mm thick and weighs just 218 g. As a result, the compact drive is easy to mount and requires very little installation space. The rotor directly drives the mechanics, which are arranged around the opening and does so without transmission. As a result, there is no mechanical backlash that...

 Open the catalog to page 9
The magazine with drive-10

A HEAD START SAVES LIVES 10

 Open the catalog to page 10
The magazine with drive-11

Anyone suffering from symptoms such as a cough, fever or headaches and muscle pains today tries to ascertain as quickly as possible whether they’ve been infected with corona, a cold or the flu. This is performed most easily using a swab. The sample can then be sent to a large-scale laboratory or – for even faster results – analyzed on-site with a point-of-care (PoC) system. In both scenarios, FAULHABER drives guarantee reliable analyses and ensure a head start in diagnostics. A fast and highly specific diagnosis of infectious diseases such as COVID-19 or influenza through polymerase chain reaction...

 Open the catalog to page 11
The magazine with drive-12

On-site analysis Prior to a surgical procedure or a drug therapy, a PoC analysis device is used to determine important parameters such as blood values, coagulation, blood gas values and electrolytes or check patients for infectious diseases such as influenza. Various technologies are used for the analyses, including fluorescence detection, polymerase chain reaction (PCR) and microfluidics. They play an important role in the fight against COVID-19 as well. The most reliable test for detecting a coronavirus infection is the PCR test. Analysis devices for PoC use are nearly fully automated and,...

 Open the catalog to page 12
The magazine with drive-13

Numerous drive tasks The drives used in the lab must perform a number of different drive tasks. Smooth operation is only possible if the individual steps occur with high dynamics and precision. For example, each sample must first be clearly identified with a bar code, the stopper unscrewed and it must be ensured that only a part of the sample is used for the analysis. Especially for tests for COVID-19 or vaccine development, it is important that part of the sample be resealed and archived for any subsequent retesting and for archiving purposes. Needed during the preparation of the samples are,...

 Open the catalog to page 13

All FAULHABER Drive Systems catalogs and technical brochures

  1. MC 3602 B

    2  Pages

  2. 14GPT

    2  Pages

  3. FAULHABER motio

    36  Pages

  4. motion 1/2020

    32  Pages

  5. motion 2/2019

    28  Pages

  6. Drives Systems

    40  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.