Human Machine Interface • High Standards of Noise Immunity and Quality • Optional Integrated Rear Mount PLC • Intuitive Software Environment and Aesthetic GUI • Powerful Programming Features
Open the catalog to page 1The FATEK P5 series provides a high quality and high performance human machine interface with the option of an integrated PLC. With its aesthetically pleasing high-gloss piano black finish, the P5 series represents the high quality and reliability expected in the industrial automation market today. The P5 series also allows the rear mounting of an integrated programmable controller saving space and installation costs. With its intuitive software programming environment and outstanding graphical representation, the P5 series helps create functional and elegant user interfaces. High Noise...
Open the catalog to page 2Remote Monitor and Control Powerful Programming Features Specification Dimensions & P5 Accessories HB1 & B1 Options
Open the catalog to page 3High Noise Immunity HMIs at industrial sites are often adversely affected by electrical noise from the surrounding installations. This can cause malfunction and lead to injury to persons or property. FATEK has focused on the P5’s stability and robustness to provide end users with a reliable HMI product that can operate in harsh conditions.
Open the catalog to page 4The P5 series provides cableless communications to the FATEK B1 PLC by offering a version that can be mounted onto the back of the P5 HMI. This provides more reliability and improves communication speeds with the added benefit of saving valuable space and installation costs. Other Brands
Open the catalog to page 5In-built Termination Resistors for RS485/422 Ports With RS-422/RS-485 communication networks, termination resistors are often required to improve the reliability of communications. External termination resistors can make communication wiring onsite complex. To solve this problem, the P5 provides built-in termination resistor switches. Terminating can be achieved by turning on the switch to connect to termination resistors, or turn off the switch to disconnect the resistors.
Open the catalog to page 6Isolated Communication Ports* HMIs are used to communicate with various devices, such as PLCs, Motion Controllers and Inverters. If the connected devices locate at the different voltage levels, a ground potential difference would occur and could cause communication errors or damage to the devices. The P5 HMI provides isolated serial communication ports to protect the internal circuit from any voltage difference of the ground.
Open the catalog to page 7Intuitive Programming Software Environment 1. Toolbar & Shortcut: Icon-based organized design, enables users to operate what they want efficiently 5 2. Project Explorer: Divide functions into 3 categories, collapsible, space-saving 3. Screen List: Screen preview allows users to access a specific screen quickly 4. Screen Workspace: What You See Is What You Get 5. Tab Page: Switch view effortlessly 6. Memory Address: View the status of memory usage Topic 1 Different Ribbon Style, Different Arrangement of Workspace FATEK Style
Open the catalog to page 8Outflow Temp Inflow Temp Change Screen Other Switch Animated Graphic Use Wizard to Complete Project Setting in Three Steps Trace every object that the user creates currently Drag the customized object into this area, and then you can use Compiling result will be displayed here. Double clicking the error message leads users to review the setting directly displaying status of the objects Change the default color scheme from several Ribbon styles Wide variety of useful, elegant objects to utilize Choose HMI Model Choose Controller Selec Step 1: Choose HMI Model Step 2: Choose Controller Step...
Open the catalog to page 9Usability Toolbox Image Library Provides many useful objects like shapes, meters, charts, buttons etc. Utilize them from the Toolbox section to speed up the design time Thousands of industrial images to choose from, or import your own images. Audio Library Use the Audio Library to play the sound you like when an alarm happens or a button is clicked. Tag Library Use the Tag Library to make controller addressing function easy to identity in the objects created. Tag libraries can be imported and exported as CSV files.
Open the catalog to page 10You can customize your own style of keypad. TrueType font is supported. The font can be scalable and anti-aliasing The capacity of font files is minimized, thus minimizing memory usage Text Library Multi-language support satisfies your requirement of localization. You can even change the language setting dynamically at runtime. Auto-alignment helps users to organize the screen layout easily. Furthermore, the gridlines can be shown or hidden to make the screen workspace clear to see. User Toolbox Drag user-defined objects into User Toolbox section, and these objects would become reusable....
Open the catalog to page 11Security and Safety Control Proprietary Rights Protection • You can set password for project protection; you need to enter project password to open the project • Project downloading, uploading and system configuration are prohibited unless users input system password • The script allows you to design custom functions for your customers. You can also set passwords to these custom functions, so that your customers will be requested to enter passwords when they want to use them or see the source code ) Upload Manager Please enter the HMI system password to proceed Security function provides 16...
Open the catalog to page 12On-Off Delay For preventing mistakes in operations, you can set minimum hold time for buttons and switches or operators have to double press the objects to execute the operation. Update User Accounts / Passwords Via External Storage To add or edit user accounts on a HMI can cause headaches for production managers. By Function Switch, the P5 series allows users to change user accounts and passwords via external storage. New User Accounts / Passwords List
Open the catalog to page 13Alarm, Trend and Data Log Alarm When alarm is triggered, operators can see the scrolling text displaying the predefined message on the assigned position, or use the alarm display to see the detailed message; audio can be played to remind the unaware operators. Use the Alarm function to set the threshold value for monitoring system status. Play Sound Scrolling Text Alarm Display Pop up the child window to get a further message or for post-processing. Review the history records of Data Log and Operation Log for root cause investigation.