The FPT15-I Portable Surge Generator is designed for on-site testing of surge protective devices and lightning strike counters. It can release a maximum discharge current of 2.5kA and features a one-key operation for charging and discharging. The device starts charging with the press of a green "Start" button, and the relay counts time until charging stops and discharging occurs. The test ends when the time relay's indication light turns off. Note: The "Start" button should not be pressed repeatedly during testing.
The control panel manages the surge generator's charging time, initially set to 3 seconds with an output voltage of 1100V and surge current of 2.5kA. Adjustments can be made to reduce the output surge current by altering the charge time, accurate to 0.1 seconds.
The SPD Tester 888 is designed for on-site testing of Surge Protective Devices (SPD) and their components. It allows for simple operation to measure a wide range of Nominal Voltage and Leakage Current, with results displayed on an easy-to-read LCD. It features precise auto-sensing shutoff and audible function indication for accurate results.
Test Device FPT15-I ♦Introduction FPT15-I Portable surge generator is designed for on-site testing of surge protective device and lightning strike counter.The surge generator is able to release max. discharge current 2.5kA, realized one-key operation of charging and discharging. Press the green “Start” button, the surge generator starts charging, the relay starts counting time until the device stop charging, while discharging. When time relay’s indication light off, the test end. Note: Green “Start” button cannot be repeated click during testing. ♦ Characteristics: -Portable type, small size. -On site testing of lightning counter. -Demonstration of SPD working. -Realized one-key operation of charging and discharging -Max. discharge current 2.5kA ♦ Panel Introduction Control surge generator charging time. The original setting display as 3S, output voltage is 1100V, output surge current is 2.5kA. If need to reduce output surge current, you can reduce the charge time, that is to adjust the time of time relay, it can accurate to 0.1S. Real-time voltage,, Charging Time Charging Voltage Control charging and discharging procedure. Check the lamp ON or OFF before and after the test. Output current waveform, testing surge protective device or other products.
Open the catalog to page 1Test Device f^FATECf/ SPD888 ♦Introduction SPD Tester 888 is designed for on-site testing of Surge Protective Devices (SPD) and the SPD’s components; This simple operation allows to measure a wide test range of the Nominal Voltage and Leakage Current.Users can determine the status of these components according to the tester readings through an easy-to-read LCD display. ♦ Characteristics: Surge Protective Devices Tester, SPD Tester 888 is designed for on-site testing of Surge Protective Devices (SPD) and the SPD’s components. This simple operation allows to measure a wide test range of the Nominal...
Open the catalog to page 23 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
4 Pages
4 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page