1. Catalogs
  2. FATECH ELECTRONIC (FOSHAN) CO., LTD
  3. FATECH surge arrester FV25B/2-275 for AC class 1 protection system

FATECH surge arrester FV25B/2-275 for AC class 1 protection system

FATECH surge arrester FV25B/2-275 for AC class 1 protection system

Product catalog summary
Specifications:
  • Remote Control Contact: Available for models with 'S' in the model number.
  • AC Specifications: Voltage ≤ 250V max, Current ≤ 0.5A max, Single core wire with a maximum diameter of 1.5mm.
  • DC Specifications: Voltage ≤ 60V max, Current ≤ 0.1A max, Multi-core wire with a maximum diameter of 1.3mm.
  • Model Numbers: FV25B/2-150(S), FV25B/2-255(S), FV25B/2-275(S), FV25B/2-320(S), FV25B/1-385(S).
  • Test Class: IEC/EN/VDE Class I/B.
  • Network Type: TT, TN.
  • Protection Mode: L-PE, N-PE.
  • Nominal Voltage: 50(60)Hz UN 110/220V~, 220/380V~.
  • Rated Voltage (UC): 150V~ to 385V~.
  • Impulse Current (Iimp): 25kA.
  • Nominal Discharge Current (In): 25kA.
  • Voltage Protective Level (Up): ≤1.6kV to ≤1.8kV.
  • Response Time (tA): ≤100ns.
  • Recommended Back-up Fuse: 315A.
  • Isolation Resistance: >10 MΩ.
  • I/O Connections: L-N: Multi-core wire 10mm ~25mm, PE: Multi-core wire >16mm.
  • Mounting: 35mm Symmetrical rail (EN50022/DIN46277-3).
  • Operating Temperature Range: -40℃ to +80℃.
  • Humidity: 30% to 90%.
  • Altitude: Up to 3000m.
  • Degree of Protection: IP20.
  • Housing Material: UL94 V-0.
  • Disconnection Indicator: Mechanical indicator (Green: OK, Red: replace).
  • Remote Control Contact: Optional.
Features:
  • Unique seal construction with multilayer spark gap, preventing spark emission outside the housing.
  • Working status indication window and remote control contacts.
  • Max continuous operating voltage options: 150V~, 255V~, 275V~, 320V~, 385V~.
  • Primarily used in lightning protection zones (LPZ) 0 to 1, suitable for building entrance lines, elevators, minerals, etc.
  • 1 phase, 2 poles.
See more

Catalog excerpts

FATECH surge arrester FV25B/2-275 for AC class 1 protection system-1

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 1 phase, 2 poles. Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 1

All FATECH ELECTRONIC (FOSHAN) CO., LTD catalogs and technical brochures

  1. iSPD

    4  Pages

  2. iSPD-M

    4  Pages

  3. FLP03-320-S/G

    2  Pages

  4. FLP03-275-S/G

    2  Pages

  5. FLP03-275-P/G

    2  Pages

  6. FLP03-24-P/G

    2  Pages

  7. FV30B+C/4

    1  Page

  8. FV10D/2

    1  Page

  9. FV40C/3+NPE

    1  Page

  10. FLRC-S/II

    1  Page

  11. FLRC-D

    1  Page

  12. FV30B+C

    1  Page

  13. FLRC-L

    1  Page

  14. FLRC-S/D

    1  Page

  15. FV20C

    1  Page

  16. FV20C/3

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.