Product catalog summary
Specifications:
  • Type: FLRC-L
  • Working Mode: 220V AC
  • Indicator Range: 0~125
  • Counting Current: 50A (rise time ≥8μs, 8/20μs waveform)
  • Maximum Lightning Current: 150kA (8/20μs waveform)
  • Date/Time Indication: Year/Month/Day/Hour/Minute/Second
  • Communication: RS485
  • Mounting: 35mm Symmetrical rail (EN50022/DIN46277-3)
  • Enclosure Material: UL94 V-0
  • Degree of Protection: IP20
  • Operation Temperature Range: -40℃ to +80℃
  • Humidity Range: 30% to 90%
  • Altitude: Up to 3000m
Features:
  • Digital lightning counter with time clock function.
  • Can register 0~999 lightning strikes; data retention during power failure.
  • Real-time logging of each lightning strike's date and time.
  • Number counting repetition up to 1 million times.
  • Requires reset after registering 125 lightning strikes to continue counting.
  • Indicates installation impact from lightning and power line surges.
  • Utilizes Zinc oxide varistors or GDT modules for surge protection.
Recommendations:
  • Reset the counter after 125 strikes to ensure continued operation.
  • Install in environments within specified temperature, humidity, and altitude ranges.
See more

Catalog excerpts

FATECH Lightning strike counter FLRC-L for checking the lightning strike record-1

Lightning Counter FLRC-L ♦ Digital type lightning counter is built with time clock function ♦ Can register 0~999 of lightning strikes, the data won’t be lost in case of power failure. ♦ Can check the real time (year/month/day/hour/minute /second) of each lightning strike ♦ Number counting repetition up to 1 million times. ♦ Please reset when the counter registers125 lightning strikes,otherwises it will not count. ♦ The counter can clearly indicate whether the installation of the lightning surge damage suffered from the impact of lightning and power line. Because we are now using either Zinc oxide varistors or GDT module only when the physical damage to the structure of these devices, we know that lightning is installed where there is lightning; But after installing lightning counter, we'll know at the surge protection products installation place.

 Open the catalog to page 1

All FATECH ELECTRONIC (FOSHAN) CO., LTD catalogs and technical brochures

  1. iSPD

    4  Pages

  2. iSPD-M

    4  Pages

  3. FLP03-320-S/G

    2  Pages

  4. FLP03-275-S/G

    2  Pages

  5. FLP03-275-P/G

    2  Pages

  6. FLP03-24-P/G

    2  Pages

  7. FV30B+C/4

    1  Page

  8. FV10D/2

    1  Page

  9. FV40C/3+NPE

    1  Page

  10. FLRC-S/II

    1  Page

  11. FLRC-D

    1  Page

  12. FV30B+C

    1  Page

  13. FLRC-L

    1  Page

  14. FLRC-S/D

    1  Page

  15. FV20C

    1  Page

  16. FV20C/3

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.