1. Catalogs
  2. FATECH ELECTRONIC (FOSHAN) CO., LTD
  3. FATECH AC SPD catalogue for power supply system

FATECH AC SPD catalogue for power supply system

FATECH AC SPD catalogue for power supply system
1 / 65 PagesView full catalog

FATECH AC SPD catalogue for power supply system

Product catalog summary
Overview: This document outlines the technical specifications and features of various surge protective devices (SPDs) designed for low-voltage power systems. These devices are primarily used for lightning protection and are suitable for different network types and protection modes.
Specifications:
  • Voltage and Current Ratings: Devices support AC voltages up to 250V and DC voltages up to 60V, with maximum currents of 0.5A for AC and 0.1A for DC.
  • Model Variants: Models offer maximum continuous operating voltages (Uc) from 150V to 385V.
  • Impulse and Discharge Current: Impulse current rating is 50kA, with a nominal discharge current of 50kA for most models.
  • Voltage Protection Level: Voltage protection level (Up) is ≤1.8kV, with some models rated at ≤2.0kV.
  • Response Time: ≤100ns.
  • Back-up Fuse: Recommended back-up fuse of 500A.
  • Isolation Resistance: Greater than 10 MΩ.
Features:
  • Construction: Unique seal construction with a multilayer spark gap, preventing spark emission outside the housing.
  • Status Indication: Working status indication window and optional remote control contacts.
  • Protection Zones: Suitable for lightning protection zones (LPZ) 0 to 1, used in building entrance lines, elevators, and mineral industries.
  • Mounting and Operation: Mounted on a 35mm symmetrical rail, operating temperature range of -40℃ to +80℃, humidity levels between 30% to 90%, and altitudes up to 3000m.
  • Protection Degree: Rated at IP20 with housing material conforming to UL94 V-0 standards.
  • Disconnection Indicator: Mechanical indicator shows green for OK and red for replacement needed.
Model Specifics:
  • FV50B Series: Available in 1 to 4 pole configurations, supporting various network types (TT, TN, IT) and protection modes (L/N-PE).
  • FV25B Series: Similar to the FV50B series but with a lower impulse current rating of 25kA and nominal discharge current of 25kA.
  • FVB12.5B+C Series: Designed for space-saving installation with a width of 18mm per pole, featuring a high discharge current of 12.5kA per pole and a maximum discharge current of 80kA.
Additional Features:
  • Low residual voltage and quick response time.
  • Reliable control with Thermo Dynamic Control disconnector.
  • Remote signaling contact for control devices.
  • Fault indication via a red mark in the inspection window.
  • Protection modes include L1, L2, L3-N, N-PE, and others depending on the model.
Installation and Connectivity:
  • Mounting: 35mm Symmetrical rail (EN50022/DIN46277-3).
  • I/O Connections: Multi-core wire ranging from 4mm to 35mm depending on the model.
  • Port Definition for Remote Control Contact: AC (U ≤250Vmax, I ≤0.5Amax), DC (U ≤60Vmax, I ≤0.1Amax).
Applications: These SPDs are suitable for use in lightning protection zones, particularly at boundaries 1-2 and 2-3, ensuring reliable screening and lower voltage protection levels.
See more

Catalog excerpts

FATECH AC SPD catalogue for power supply system-1

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~ for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 1 pole. Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 1
FATECH AC SPD catalogue for power supply system-2

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~ for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 1 phase,2 poles. Port definition of remote control contact Range of signal access Remark: if the model number is without“S”, the model is without remote control...

 Open the catalog to page 2
FATECH AC SPD catalogue for power supply system-3

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 3 phase,3 poles. Port definition of remote control contact Range of signal access Remark: if the model number is without“S”, the model is without remote control...

 Open the catalog to page 3
FATECH AC SPD catalogue for power supply system-4

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 3 phase,4 poles. Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 4
FATECH AC SPD catalogue for power supply system-5

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 1 pole. Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 5
FATECH AC SPD catalogue for power supply system-6

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 1 phase, 2 poles. Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 6
FATECH AC SPD catalogue for power supply system-7

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 3 phase,3 poles. Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 7
FATECH AC SPD catalogue for power supply system-8

Surge Protective Device for Low-voltage Power System ♦ Adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. ♦ With working status indication window, and remote control contacts. ♦ Max.continuos operating voltage(Uc)150V~,255V~, 275V~,320V~,385V~for your option. ♦ Mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines elevator, mineral, and so on. ♦ 3 phase,4 poles. Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 8
FATECH AC SPD catalogue for power supply system-9

Surge Protective Device for Low-voltage Power System ♦ Surge protective device with special design for saving installation space--- width 18mm/pole. ♦ High discharge current--- Iimp 12.5kA per pole. ♦ each pole with one indication window, indication window for clear display of SPD status. ♦ Remote controlling function for your option. ♦ Pluggable module--- convenient for maintenance. ♦ Protection mode --- L/N-PE. ♦ 1 pole. Port definition of remote control contact Range of signal access Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 9
FATECH AC SPD catalogue for power supply system-10

Surge Protective Device for Low-voltage Power System (S) ♦ Surge protective device with special design for saving installation space--- width 18mm/pole. ♦ High discharge current--- Iimp 12.5kA per pole. ♦ each pole with one indication window, indication window for clear display of SPD status. ♦ Remote controlling function for your option. ♦ Pluggable module--- convenient for maintenance. ♦ Protection mode --- L-PE,N-PE. ♦ 1 phase, 2 poles. Remark: if the model number is without“S”, the model is without remote control contact function

 Open the catalog to page 10

All FATECH ELECTRONIC (FOSHAN) CO., LTD catalogs and technical brochures

  1. iSPD

    4  Pages

  2. iSPD-M

    4  Pages

  3. FLP03-320-S/G

    2  Pages

  4. FLP03-275-S/G

    2  Pages

  5. FLP03-275-P/G

    2  Pages

  6. FLP03-24-P/G

    2  Pages

  7. FV30B+C/4

    1  Page

  8. FV10D/2

    1  Page

  9. FV40C/3+NPE

    1  Page

  10. FLRC-S/II

    1  Page

  11. FLRC-D

    1  Page

  12. FV30B+C

    1  Page

  13. FLRC-L

    1  Page

  14. FLRC-S/D

    1  Page

  15. FV20C

    1  Page

  16. FV20C/3

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.