1. Catalogs
  2. Faster s.r.l.
  3. SafeFAST Classic

SafeFAST Classic

SafeFAST Classic

SafeFAST Classic

Product catalog summary
Introduction
SafeFAST Classic Class II Microbiological Safety Cabinets are designed by Faster S.r.l. to provide protection, safety, and reliability while minimizing environmental impact. These cabinets are equipped with advanced technologies to ensure sustainable progress and meet high safety standards.

Environmental Commitment
Faster S.r.l. emphasizes low environmental impact by using certified low pressure-drop HEPA filters, electronically controlled motor-blowers, and recyclable components. The ECS® microprocessor optimizes power consumption and reduces CO2 emissions.

Quality Assurance
Each cabinet is tested according to EN 12469:2000 and EN 61010:2001 standards, ensuring absolute safety for operators. The Faster Quality and Safety Program ensures high manufacturing standards.

Hardware Features
  • Anti-bacterial coating with Dupont™ ALESTA® to prevent microbial contamination.
  • Low noise levels due to special design and materials.
  • Stainless Steel AISI 304L work-surface for durability.
  • Real laminar flow for optimal air patterns.

Software Features
  • Instant management and monitoring via ECS® microprocessor.
  • Programmable replacement regime for parts and filters.
  • Permanent record of alarms and anomalies.
  • One Push Restore menu for factory calibration reset.

Customer Care
Faster provides prompt technical assistance and offers custom-made special cabinets upon request.

Certifications
The cabinets hold double ISO 9001, TUV, and LNE certifications.

Applications
These cabinets are used globally in microbiology, virology, haematology, cell culture, genetics, and handling hazardous agents.

Operational Principles
The cabinets use a vertical laminar flow system with 70% air recirculation and 30% exhaust through HEPA filters, ensuring compliance with EN-12469:2000 standards.

Monitoring System
The ECS® microprocessor provides a full status report and controls all functions and safety alarms. A user-friendly keyboard and LCD display keep users informed of cabinet conditions.

Additional Features
  • Electrically operated sash window with adjustable height.
  • Easy installation and maintenance with removable work surfaces and UV sterilizing lamp.
  • Silent operation with low sound-pressure levels.
  • High-level lighting and ergonomic design for user comfort.

Technical Specifications
The cabinets are available in various sizes with specific dimensions, weight, exhaust flow rate, noise level, lighting level, and electrical data.

Options and Accessories
Various options and accessories are available, including different work surfaces, UV lights, additional taps, and adjustable floor stands.
See more

Catalog excerpts

SafeFAST Classic-1

SafeFAST Classic Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

 Open the catalog to page 1
SafeFAST Classic-2

New technologies for a low environmental impact Fully aware that our choices of today will determine and shape our fates tomorrow, our company - FASTER S.r.l. - are convinced that technology must protect the environment to ensure a continuing sustainable progress. Respect for the environment motivates FASTER to manufacture laminar-flow and microbiological safety cabinets possessing ultra-low environmental impact, by utilizing: Certified ‘low pressure-drop’ HEPA filters providing up to 30% saving on Electronically controlled motor-blower with automatic pressure-drop compensation sor employs the...

 Open the catalog to page 2
SafeFAST Classic-3

Absolute safety for the operator. Always Manufacturing truly “safe” cabinets depends entirely on the quality of their design and components. Aware of the fact that our guarantees for safety do not tolerate any compromises, our company has created its internal FASTER QUALITY AND SAFETY PROGRAM - consisting of a new set of standard operational procedures and manufacturing methods - applied to each and every step of the production processes aimed at fulfilling all requirements of these high standards. CUSTOMER CARE ANTI BACTERIAL COATING Each FASTER cabinet is coated with exclusive Dupont™ ALESTA®...

 Open the catalog to page 3
SafeFAST Classic-4

SafeFAST Classic Class II Microbiological Safety Cabinets BEYOND MINIMUM SAFETY REQUIREMENTS SafeFAST Classic Microbiological Safety Cabinets belong to the latest generation of laminar air flow systems manufactured by Faster S.r.l. SafeFAST Classic cabinets, currently surpass most known “value for money” Microbiological Safety Cabinets on the market. SafeFAST Classic vertical laminar flow cabinets are Class II Microbiological Safety Cabinets designed and built to performance requirements of the EN-12469:2000 European Standard, with 70% of the air re-circulated via the main Class H14 HEPA filter...

 Open the catalog to page 4
SafeFAST Classic-5

SafeFAST Classic Class II Microbiological Safety Cabinets THE USER-FRIENDLY PRACTICAL KEYBOARD ECS® MICROPROCESSOR BASED MONITORING SYSTEM: full status report provided via 2-line digital display by the new generation microprocessors which automatically control all functions and all safety alarm systems ensuring that performance characteristics are maintained to EN12469:2000 requirements. High power lithium battery keeps safety data saved to microprocessor system. THE USER-FRIENDLY PRACTICAL KEYBOARD and the rear-lit LCD will continuously display all required data keeping the user constantly informed...

 Open the catalog to page 5
SafeFAST Classic-6

REMOVABLE UV STERILIZING LAMP Removable UV sterilizing lamp (optional) that can be easily placed in each area of the back panel. Complete with two switchoff countdown timers, one variable on a 0÷3 hours scale (1 minute steps), the other set to 3 fixed hours. ELECTRICALLY OPERATED SASH WINDOW The standard height of the work position sash is set to 200mm. Alternative sash-height settings (250 -160 mm) by the factory are available upon request. 440 mm maximum opening. REMOVABLE WORK SURFACE Work Surface in stainless steel AISI 304L consisting of sections which are easily removable for carrying out...

 Open the catalog to page 6
SafeFAST Classic-7

EASY CLEANING / MAINTENANCE Electrically operated vertically sliding safety-glass sash window, which is also hinged and can be opened up during cleaning and routine maintenance. CABINET ELEMENTS IP 44 electrical socket is fitted as standard in each size model. Servicing holes are positioned on the side glasses for taps installation (as option). SILENT OPERATION The bag plenum, the structures of the electric motor of the fan fitted on its antivibration mounts and the software itself designed to provide optimum air handling characteristics guarantee quiet operation of this silent safety cabinet,...

 Open the catalog to page 7
SafeFAST Classic-8

TECHNICAL SPECIFICATIONS SafeFAST Classic Overall Dimensions Jsefull Dimensions Working aperture Maximum front aperture mm jghting leve zlectrical Data nternal electrical outlet The electrical outlets have a total load capacity of 4A Heat emissior (1) The total depth of the cabinet can be easily reduced to 780 mm removing the back panel (2) At operation condition according to EN12469: 2000. (3) Clean filters, lighting activated, internal outlet load excluded * Alternative sash-height settings (250-160 mm) by the factory are available upon request • Solid Work Surface* Single Section Work Surface*...

 Open the catalog to page 8

All Faster s.r.l. catalogs and technical brochures

  1. Pass Boxes

    2  Pages

  2. FasterUnit

    2  Pages

  3. SmartFAST

    6  Pages

  4. FlowFAST V

    4  Pages

  5. FlowFAST H

    6  Pages

  6. SafeFAST Top

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.