Hardware Specifications
  • Power Supply: 230Vac - 50/60Hz.
  • Microcontroller: Utilizes flash technology for electronic control.
  • Display: 3-digit BLUE LED for time/temperature.
  • Controls: 4-button keyboard (On-Standby/Enter, Down, Up, Light).
  • Inputs: 2 analog for NTC thermistor sensors, 1 digital for door microswitch.
  • Outputs: Up to 5 digital relay outputs for various functions.
  • Acoustic Signals: Provided by a piezoelectric buzzer.
  • Connections: Phoenix type for removable screw terminals.
  • Board Fixing: Non-metallic spacers, minimum 10mm distance from support base.
Functional Specifications
  • Temperature Conservation: Low temperature with manual or automatic defrosting.
  • Security: Keypad lock and password-protected configuration menu.
  • Alarm Signaling: For probe failures, open door, high temperature, high pressure, and black-out.
  • Factory Reset: Capability to reset to factory data.
User Interface Commands
  • SW4 (ON/SBY/ENTER): Switches display, standby mode, confirms settings.
  • SW3 (DOWN): Decreases values, displays minimum temperature and alarms.
  • SW2 (UP): Increases values, displays maximum temperature, initiates defrost.
  • SW1 (LIGHT): Controls lighting.
LED Indicators
  • Defrost LED: Indicates defrosting status.
  • Fan LED: Indicates fan activation.
  • Compressor LED: Indicates compressor activation.
Temperature Setpoint and Modification
  • Adjustable via On/Sby/Enter and Up/Down keys, confirmed by beeps.
Keyboard Lock
  • Activated by pressing Up and Down keys simultaneously for over 3 seconds.
Relative Humidity Modification
  • Adjusted via Down button, with confirmation labels.
Parameters Configuration
  • Accessed via Up and Down keys, password-protected, allows parameter scrolling and modification.
Compressor and Fan Control
  • Compressor: ON/OFF based on cell probe temperature.
  • Evaporator Fans: Configurable based on probe presence and compressor status.
Defrosting Management
  • Manual or automatic, options for ventilation, resistance, or hot gas. Ends by timeout or temperature set by parameter.
Condenser Fan Control
  • Configurable based on probe presence and compressor status.
Door Opening Management
  • Indicated by flashing "doo" label, deactivates evaporator fan when open.
Alarm Management
  • High Temperature Alarm: Triggered by exceeding setpoint + hysteresis + parameter A2.
  • Low Temperature Alarm: Triggered by dropping below setpoint + parameter A1.
  • Black Out Alarm: Activated after power failure, indicated by flashing defrost LED and 'bLo' display.
  • Door Open Alarm: Triggered if door remains open beyond set time, indicated by flashing 'dA' label.
  • High Condensation Temperature Alarm: Activated when condenser temperature exceeds threshold, indicated by 'HtC'.
  • High Pressure Alarm: Triggered by excessive condenser temperature, indicated by 'HP'.
  • Probe Alarms: Faulty probes trigger specific alarms ('E0', 'E1', 'E2').
Factory Parameters Reset
Parameters can be reset to factory settings by pressing the On/Sby/Enter key three times during the test phase, indicated by 'rLd' on the display.Parameters List
The document includes a comprehensive list of configuration parameters for measurement inputs, compressor adjustment, defrost settings, alarm management, and fan adjustments. Each parameter has a default, minimum, and maximum value, allowing customization of the device's operation.
See more

Catalog excerpts

FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-1

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044 HARDWARE SPECIFICATIONS Electronic Refrigerator board • Mains power supply: 230Vac - 50 / 60Hz. • Electronic control system through microcontroller with flash technology. • Retention of the operating parameters. • 3 digit BLUE LED display for time / temperature. • Controls via 4-button keyboard (On-Standby / Enter, Down, Up, Light). • 2 analog inputs for NTC thermistor type temperature sensors, 1 digital input for door microswitch management. • up to 5 digital relay outputs: 1. compressor relay, NO contact 250Vac - 16A; 3. light relay , NO contact 250Vac - 10A; 4. defrost relay , NO and NC contacts 250Vac - 10A; 5. capacitor relay , NO contact 250Vac - 10A. • Acoustic signals via piezoelectric buzzer. • Phoenix type connections for removable screw terminals. • Terminal identification by screen printing on the printed circuit board • The board is provided with holes for fixing to the panel by means of non-metallic spacers (available on request), minimum distance of 10mm between the printed circuit board and the support base . FUNCTIONAL SPECIFICATIONS • Low Temperature (LT) conservation. • Manual or automatic defrosting . • Keypad lock function. • Access to the configuration menu of the operating parameters (password protected) by pressing 2 keys simultaneously. • Alarm signaling for chamber, evaporator or condenser probe fail, for open door, for high condensing temperature, for high pressure, for black-out. • Possibility to reset the factory data through a specific procedure. P.IVA! 0202 1 450420 - R.E.A. N° 1 554D8 ANCONA - REG.lMPRESE N° 1 5DS5 ANCONA CAPI TALE sociale: €. 62.000

 Open the catalog to page 1
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-2

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it CZFASAR F^elettronica AZIENDA CERTIFICATA UNI EN ISO 9001: 2015 Input-output scheme : Electronic board dimensions (all dimensions are expressed in mm): P.IVAI D2D2l45D42a - R.E.A. N°1 554DS ANCONA - REE.lMPRESE 5DB5 ANCDMA

 Open the catalog to page 2
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-3

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it PLEASE NOTE: Read the following instruction manual carefully . The working parameters currently set by default are a standard configuration , check and and eventually configure the parameters appropriately for your application. With the controller in normal operation, the display shows the cell temperature . SW4 ON / SBY / ENTER button Pressed and released it allows to switch on the display the reading of the cell probe with the temperature setpoint set...

 Open the catalog to page 3
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-4

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it SW1 LIGHT button Pressed and released it activates / deactivates lighting. DEFROST LED Led on : defrosting in progress Flashing Led : delayed activation of defrosting or dripping in progress High frequency flashing Led : alarm recorded in memory FAN LED Led on: cell fan activated Flashing Led: delayed activation of fans COMPRESSOR LED Led on: cell compressor activated Flashing Led: delayed activation of compressor TEMPERATURE SETPOINT SETTING AND MODIFICATION...

 Open the catalog to page 4
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-5

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it ri FASAR F»elettronica AZIENDA CERTIFICATA UNI EN ISO 9001: 2015 PARAMETERS CONFIGURATION - Press the Up and Down keys simultaneously for more than 3 seconds to enter the Parameter configuration menu. - The flashing label " Loc" is displayed. - Use the Up and Down keys to display the " PAr " label . - Press the On / Sby / Enter key to enter the parameter configuration mode (after 30 seconds the function is exited if it is not confirmed) - The access password...

 Open the catalog to page 5
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-6

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it The evaporator fan control is parameterized and the following cases can be configured: • evaporator probe absent (J2 = 0 and J 2 = 2) and fans always on during storage, not related to the compressor (F3 = 1) ; • evaporator probe absent (J2 = 0 and J2 = 2) and evaporator fans managed in parallel with the compressor (F3 = 2) : on if the compressor is ON and off if the compressor is OFF. • evaporator probe present (J2 = 1) and evaporator fans managed in ON...

 Open the catalog to page 6
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-7

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it FASAR elettronica AZIENDA CERTIFICATA UNI EN ISO 9001: 2015 Case B : d1 = 0 F4 = 1 - evaporator fans active during defrosting or activated according to F3 . Manual defrosting by hot gas: Case A : d1 = 1 F4 = 0 - evaporator fans not active during defrost and F5 = delay in activating fans after dripping Case B : d1 = 1 F4 = 1 - evaporator fans active during defrosting or activated according to F3 Manual defrost by ventilation: d1 = 0 and F4 = 1: it is possible...

 Open the catalog to page 7
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-8

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it Automatic defrosting by hot gas: Case A : d1 = 1 F4 = 0 - evaporator fans not active during defrost and F5 = delay in activating fans after dripping . Case B: d1 = 1 F4 = 1 - evaporator fans active during defrosting or activated according to F3 . Automatic defrost by ventilation: d1 = 0 and F4 = 1: it is possible to carry out the defrost by ventilation without using the resistance. There is no dripping. CONDENSER FAN CONTROL The control of the condenser...

 Open the catalog to page 8
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-9

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it ALARM MANAGEMENT HIGH TEMPERATURE ALARM If the temperature in the cell is higher than the set setpoint + the compressor hysteresis value + the value of a parameter A2 , after the time A6 has elapsed, the display shows the label " AH " alternating with the high temperature reached in the cell. An intermittent acoustic signal is also activated for the time set with A5, if parameter A4 = 1 . If A4 = 0 the buzzer will sound continuously for the duration of...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.