  3. FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044

FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044
1 /13Pages

FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044

FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044
1 /13Pages

Catalog excerpts

FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-1

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044 HARDWARE SPECIFICATIONS Electronic Refrigerator board • Mains power supply: 230Vac - 50 / 60Hz. • Electronic control system through microcontroller with flash technology. • Retention of the operating parameters. • 3 digit BLUE LED display for time / temperature. • Controls via 4-button keyboard (On-Standby / Enter, Down, Up, Light). • 2 analog inputs for NTC thermistor type temperature sensors, 1 digital input for door microswitch management. • up to 5 digital relay outputs: 1. compressor relay, NO contact 250Vac - 16A; 3. light relay , NO contact 250Vac - 10A; 4. defrost relay , NO and NC contacts 250Vac - 10A; 5. capacitor relay , NO contact 250Vac - 10A. • Acoustic signals via piezoelectric buzzer. • Phoenix type connections for removable screw terminals. • Terminal identification by screen printing on the printed circuit board • The board is provided with holes for fixing to the panel by means of non-metallic spacers (available on request), minimum distance of 10mm between the printed circuit board and the support base . FUNCTIONAL SPECIFICATIONS • Low Temperature (LT) conservation. • Manual or automatic defrosting . • Keypad lock function. • Access to the configuration menu of the operating parameters (password protected) by pressing 2 keys simultaneously. • Alarm signaling for chamber, evaporator or condenser probe fail, for open door, for high condensing temperature, for high pressure, for black-out. • Possibility to reset the factory data through a specific procedure. P.IVA! 0202 1 450420 - R.E.A. N° 1 554D8 ANCONA - REG.lMPRESE N° 1 5DS5 ANCONA CAPI TALE sociale: €. 62.000

 Open the catalog to page 1
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-2

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it CZFASAR F^elettronica AZIENDA CERTIFICATA UNI EN ISO 9001: 2015 Input-output scheme : Electronic board dimensions (all dimensions are expressed in mm): P.IVAI D2D2l45D42a - R.E.A. N°1 554DS ANCONA - REE.lMPRESE 5DB5 ANCDMA

 Open the catalog to page 2
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-3

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it PLEASE NOTE: Read the following instruction manual carefully . The working parameters currently set by default are a standard configuration , check and and eventually configure the parameters appropriately for your application. With the controller in normal operation, the display shows the cell temperature . SW4 ON / SBY / ENTER button Pressed and released it allows to switch on the display the reading of the cell probe with the temperature setpoint set...

 Open the catalog to page 3
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-4

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it SW1 LIGHT button Pressed and released it activates / deactivates lighting. DEFROST LED Led on : defrosting in progress Flashing Led : delayed activation of defrosting or dripping in progress High frequency flashing Led : alarm recorded in memory FAN LED Led on: cell fan activated Flashing Led: delayed activation of fans COMPRESSOR LED Led on: cell compressor activated Flashing Led: delayed activation of compressor TEMPERATURE SETPOINT SETTING AND MODIFICATION...

 Open the catalog to page 4
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-5

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it ri FASAR F»elettronica AZIENDA CERTIFICATA UNI EN ISO 9001: 2015 PARAMETERS CONFIGURATION - Press the Up and Down keys simultaneously for more than 3 seconds to enter the Parameter configuration menu. - The flashing label " Loc" is displayed. - Use the Up and Down keys to display the " PAr " label . - Press the On / Sby / Enter key to enter the parameter configuration mode (after 30 seconds the function is exited if it is not confirmed) - The access password...

 Open the catalog to page 5
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-6

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it The evaporator fan control is parameterized and the following cases can be configured: • evaporator probe absent (J2 = 0 and J 2 = 2) and fans always on during storage, not related to the compressor (F3 = 1) ; • evaporator probe absent (J2 = 0 and J2 = 2) and evaporator fans managed in parallel with the compressor (F3 = 2) : on if the compressor is ON and off if the compressor is OFF. • evaporator probe present (J2 = 1) and evaporator fans managed in ON...

 Open the catalog to page 6
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-7

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it FASAR elettronica AZIENDA CERTIFICATA UNI EN ISO 9001: 2015 Case B : d1 = 0 F4 = 1 - evaporator fans active during defrosting or activated according to F3 . Manual defrosting by hot gas: Case A : d1 = 1 F4 = 0 - evaporator fans not active during defrost and F5 = delay in activating fans after dripping Case B : d1 = 1 F4 = 1 - evaporator fans active during defrosting or activated according to F3 Manual defrost by ventilation: d1 = 0 and F4 = 1: it is possible...

 Open the catalog to page 7
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-8

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it Automatic defrosting by hot gas: Case A : d1 = 1 F4 = 0 - evaporator fans not active during defrost and F5 = delay in activating fans after dripping . Case B: d1 = 1 F4 = 1 - evaporator fans active during defrosting or activated according to F3 . Automatic defrost by ventilation: d1 = 0 and F4 = 1: it is possible to carry out the defrost by ventilation without using the resistance. There is no dripping. CONDENSER FAN CONTROL The control of the condenser...

 Open the catalog to page 8
FUNCTIONAL SPECIFICATIONS OF THE ELECTRONIC BOARD for LowTemperature SHOWCASE p/n FE1044-9

FASAR ELETTRONICA S.r.L. Strada della Marina, 9/6 60019 Senigallia (AN) Tel.: 071.6609805 Fax: 071.6611573 E-mail: [email protected] www.fasar.it ALARM MANAGEMENT HIGH TEMPERATURE ALARM If the temperature in the cell is higher than the set setpoint + the compressor hysteresis value + the value of a parameter A2 , after the time A6 has elapsed, the display shows the label " AH " alternating with the high temperature reached in the cell. An intermittent acoustic signal is also activated for the time set with A5, if parameter A4 = 1 . If A4 = 0 the buzzer will sound continuously for the duration of...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.