TC-48 Series
1 /2Pages

TC-48 Series

TC-48 Series
1 /2Pages

Catalog excerpts

TC-48 Series-1

Preset Timer/Counter/Tachometer TC-48 Series FEATURES: Highly visible backlit LCD display Visual alerts when output status changes 2 output relays PNP/NPN selectable DC-voltage inputs Up/down, add/subtract and quadrature inputs 12VDC supply for powering sensor and encoders Keypad lock out functions Communications for connecting to PC/HMI Free Software to connect to a PC Low cost DESCRIPTION: This series is a 6-digit multifunction programmable preset Timer/Counter/Tachometer with a communication interface. This series can be connected to a PC for programming and logging of data. It has RS-232, RS-485, RS-422 Serial Communications and supports Modbus protocol. The Timer has 10 output modes and 10 timing ranges in 3 configurations. The Counter has 12 output and 5 input modes in 6 configurations and scaling for displaying of specific units or lengths. The Tachometer displays rate per second (Hz) in 4 output modes. SPECIFICATIONS: General Specifications Model TC-Pro482CRA or TC-Pro482CRA-D (din rail mount) TC-Pro482CRD or TC-Pro482CRD-D (din rail mount) Function Digital timer/counter/tachometer Supply voltage 100-240VAC (50/60Hz) ±10%, 24VDC ±10% (permissible ripple:20% (p-p) max.) Power consumption Approx. 6.2VA at 264VAC, Approx. 5.1VA at 26.4VAC, Approx. 2.4W at 24VDC Mounting method Panel mounting (45 x 45mm cutout) / ”-D” din rail or surface mount External connections Screw terminals, tightening torque 0.5 N•m Max. Display 6 Digit 7-segment, LCD display, Present value: 9-mm-high characters, white, Set value: 4-mm-high characters, white Input method NPN No-voltage (contact closure) input ON impedance: 1kΩ max. (leakage current: 5-20 mA at 0Ω) ON residual voltage: 3V max. OFF impedance: 100kΩ min. PNP Voltage Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ Output method Relay, (optional transistor output) Output 2 SPST NO (SPDT DIN rail mount version) contact output: 5A at 250 VAC, resistive load (cosФ=1). Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value). Optional transistor output: NPN open collector, max. 100mA at 30 VDC Residual voltage: 1.5 VDC max. (approx. 1V) Output time 0000.01-9999.99s Output supply 12VDC (+15%), 80mA Keypad lockout Yes, 5 key protection modes Sensor waiting time 250 ms max. (control output is turned OFF and no input is accepted during sensor waiting time) Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Ambient temperature Operating: -10 to 55°C, Storage: -25 to 65°C, (with no icing or condensation), 25% to 85% humidity Case Black plastic Attachments Waterproof gasket, flush mounting adapter ( panel mount version only) Life expectancy Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (5 A at 250 VAC, resistance load) Weight Approx. 168g Timer Specifications Functions Timer, Twin Timer or 2-Stage Timer Time range 99.999s (0.001-s unit), 9999.99s (0.01-s unit), 99999.9s (0.1-s unit)999999s (1-s unit), 9999min59s (1-s unit), 99999.9min (0.1-min unit),999999min (1-min unit), 9999h59min (1-min unit), 99999.9h (0.1-h unit), 999999h (1-h unit) Timer mode Elapsed time (UP), Remaining time (down) (selectable) Input signals Signal, reset, gate Signal, Reset, Gate Minimum input signal width: 1 or 20 ms (selectable, same setting for all inputs) Power reset Minimum power-opening time: 0.5 s (exceptA-3, b-1 and F mode) Reset system Power reset (execptA-3, b-1and F mode), external and manual reset Output modes A, A-1, A-2, A-3, b, b-1, d, E, F, Z, ton or toff

 Open the catalog to page 1
TC-48 Series-2

Preset Timer/Counter/Tachometer Counter Specifications Function 1-stage counter, 2-stage counter, total counter, batch counter, dual counter, and tachometer (selectable) Digits 6 digits, PV/SV (-99,999~999,999) Input signal CP1, CP2, reset1, and reset 2 Max. counting speed 30 Hz or 5kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2 Input mode Increment, decrement, command, individual, and quadrature Reset input Minimum input signal width: 1/20 ms (selectable, same setting for all inputs) Reset system External, manual, and automatic reset (internal according to C,R,P and Q mode...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.