PRODUCTS OVERVIEW Expertise in Control ol & Protection Solutions ons
Open the catalog to page 1At Fanox, we are specialized in the DESIGN and MANUFACTURE of Electronic Relays for Low and Medium Voltage Applications. Fanox was founded in 1992 with the clear objective of bringing innovation to the electricity sector. As a driver of technology and trends, it is consolidating in the energy market as a powerful manufacturer of many Protection Relays that can be used in any application in Transmission and Distribution Lines. The energy transition faced by the electricity sector has as one of its objectives the increase of renewable energies within the electricity mix to achieve the levels...
Open the catalog to page 2All our relays are adapted to the technical specifications and requirements of our customers, obtaining the best technical solution to meet their application and assembly needs. Fanox has manufactured only in the past year 2023 more than 97.000 medium voltage protection relays, been certified in many of the larges electric utilities worldwide. Our goal is to make electrical power safer. CUSTOMERS & APPROVALS WORLDWIDE
Open the catalog to page 3index Protection Relays OC&EF Dual and Self Powered Protection Relay OC&EF Dual and Self Powered Protection Relay OC&EF Dual and Self Powered Protection Relay OC&EF Protection Relay OC&EF Feeder Protection Relay Line, Feeder & Generator Protection Relay Feeder & Generator Protection Relay / Compact Size LPIT Feeder Protection Relay Voltage & Frequency Protection Relay Current sensors Voltage sensors Overhead Control / RTU & Feeder Protection Relay Recloser Control & Feeder Protection Relay / Compact Size Voltage sensors Voltage sensors PROTECTION & MEASUREMENT FUNCTIONS I SELF POWERING...
Open the catalog to page 4SIA-B Std. SIA-B Spec. Capacitor bank Arc flash Overhead Control Wind power Solar power Grid Interconnection Wind Power Solar Power Capacitor Bank Grid interconnection
Open the catalog to page 5index Other medium voltage products Current transformers Resistive Voltage Sensors Trip Capacitors Auxiliary Battery Power Supply Testing Blocks & Plugs Communication Software
Open the catalog to page 6Communications & Automation Solutions for Grid Digitalisation Remote Control Unit | RTU Redundancy Protocols Gateway (PRP/HSR) PROTECTION & CONTROL Protection & Control of Motors, Generators and Pumps Protection Against Transient Overvoltage Strikers Control & Measurement Earth Leakage Protection
Open the catalog to page 7DISTRIBUTION GRID
Open the catalog to page 8SELF POWERED TECHNOLOGY SOLUTION INTELLIGENCE APPLIED TO PROTECTION RELAYS We are a reference as specialists in SELF POWERED Protection Relays designing and manufacturing. Successfully proven experience, thousands of field installed devices operating in top conditions for over 15 years. Our innovative spirit, the direct care of the market requirements and our extensive expertise in the manufacture of Protection Relays, have made our Self powered Relays a reference worldwide. Furthermore, our Relays include the latest Technology: LCD, keyboard, event recording, SCADA communication, PC...
Open the catalog to page 9Secondary Distribution Protection RMUS, MRMUS, AND SF6 INSULATED SWITCHGEARS OC&EF DUAL & SELF POWERED PROTECTION RELAY • The SIA-B is an OC&EF protection relay with self-powered and dual-powered (self-powering + auxiliary power) options. • The relay is self-powered using the operating current through three /1 (<2VA) standard current transformers fitted on the lines. These transformers are also used to obtain current measurements. Besides, SIA-B can be used with auxiliary power supply (24-230Vac/dc). The relay can also be supplied by a USB cable connected to the laptop or with a standard...
Open the catalog to page 10ANSI CODE PROTECTIONS ADDITIONAL FUNCTIONS Instantaneous phase overcurrent Inverse time phase overcurrent Real Time Clock Instantaneous measured neutral overcurrent Programmable Logic Control Human Machine Interface Inverse time measured neutral overcurrent Sequential Event Recording Second Harmonic Blocking Disturbance Fault Recording External trip Load Data Profiling Phase balance current protection Thermal overload Settings Groups Cold Load Pickup Breaker wear monitoring Circuit Breaker Failure Zone selection interlocking Trip block for switch disconnector Programmable logic control
Open the catalog to page 11RELAY MODEL SELECTION Overcurrent & Earth Fault Protection Relay – Dual & Self-powered PHASE CURRENT MEASUREMENT 1A NEUTRAL CURRENT MEASUREMENT 1A NET FREQUENCY Defined by General Settings POWER SUPPLY Self-powered + Commissioning battery Self-powered + 24-230 Vac/dc (Dual) + Commissioning battery ADDITIONAL FUNCTIONS + 49 + SHB + 4 Settings groups + LDP + DFR + 52 + 49 + SHB + 4 Settings groups + LDP + DFR + 52 + 46 + Trip Block + 50_2 + 50G_2 + CLP + 50BF COMMUNICATIONS USB (Modbus RTU) USB (Modbus RTU) + RS485 (Modbus RTU or DNP3.0 Serial) INPUTS AND OUTPUTS 4 LEDs + Trip (Striker) + 3...
Open the catalog to page 12Secondary Distribution Protection RMUS, MRMUS, AND SF6 INSULATED SWITCHGEARS OC&EF DUAL & SELF POWERED PROTECTION RELAY • The SIA-B is an OC&EF protection relay with self powered and dual powered (self-powering + auxiliary power) options. • The relay is self powered using the operating current through three specific current transformers fitted on the lines. These transformers are also used to obtain current measurements. Besides, SIA-B can be used with auxiliary power supply (24230Vac/dc). The relay can be also supplied by a USB cable connected to the laptop, with the USB KITCOM adapter or a...
Open the catalog to page 14ANSI CODE PROTECTIONS ADDITIONAL FUNCTIONS Instantaneous phase overcurrent Real Time Clock Inverse time phase overcurrent Programmable Logic Control Instantaneous calculated neutral overcurrent Human Machine Interface Sequential Event Recording Inverse time calculated neutral overcurrent Disturbance Fault Recording Second Harmonic Blocking External trip Settings Groups Thermal overload Trip block for switch disconnector Programmable logic control
Open the catalog to page 15RELAY MODEL SELECTION Overcurrent & Earth Fault Protection Relay – Dual & Self-powered PHASE CURRENT MEASUREMENT Defined by General Settings NEUTRAL CURRENT MEASUREMENT Internal measurement NET FREQUENCY Defined by General Settings POWER SUPPLY Self powered Self powered + Commissioning battery Self powered + 24-230 Vac/dc (Dual) Self powered + 24-230 Vac/dc (Dual) + Commissioning battery ADDITIONAL FUNCTIONS + 49 + SHB + 49 + SHB + Trip block for switch disconnector + Trip Block for switch disconnector COMMUNICATIONS USB (Modbus RTU) USB (Modbus RTU) + RS485 (Modbus RTU) INPUTS AND OUTPUTS...
Open the catalog to page 16