Catalog excerpts
ENGINEERED VALVES Sampling Valves Tank Bottom Valves Charging Valves
Open the catalog to page 1TABLE OF CONTENTS FAMAT 3 FAMAT Sampling Valves (main components) 4 FAMAT patented EPT® (Expanding Piston Technology) 5 125TC (Tri-clamp Easy-clean Valve) 8 125CC (Crust Breaking Valve) 9 125OEL (High Containment Valve) 11 125M (High temperature Valve) 12 125NIR (Valve with Infra-red Probe) 14 130TC (Tri-clamp Easy-clean Valve) 16 130TC (Tri-clamp Easy-clean Valve) 17 130CC (Crust Breaking Valve) 18 130OEL (High Containment Valve) 20 DN15 SAMPLING VALVES 115G (Gas Sampling Valve) 21 115TC (Tri-clamp Easy-clean Valve) 22 HORIZONTAL SAMPLING VALVES...
Open the catalog to page 2FAMAT is a Swiss engineering company for 40 years in the development and manufacturing of valves applications for projects in : A - SAMPLING VALVES • Water Works • Power Generation • Petro-Chemical • Oil and Gas For the Pharmaceutical, Bio-technological and Chemical industry, FAMAT supplies a complete range of products and services allowing the sampling of products in the best conditions of efficiency in terms of representativity of the samples, security, cleanliness and availibility. With its impressive references in the Pharmaceutical and Chemical production business (Roche, Novartis,...
Open the catalog to page 3FAMAT SAMPLING VALVE MAIN COMPONENTS Connection flange Piston Handwheel Venting valve Quick coupling Sampling bottle SIMPLE DESIGN FOR MAXIMUM RELIABILITY & PERFORMANCE FAMAT
Open the catalog to page 4FAMAT PATENTED EPT® EXPANDING PISTON TECHNOLOGY Almost all FAMAT valves are based on our patented Expanding Piston Technology EPT®. The patented system inside this piston allows the PTFE external coat to expand and insure a perfect tightness from vacuum up to full rating pressure 10 bar (145 psi). The advantage of having an expandable piston inside the valve is to eliminate the need for O-rings that can be damaged during valve operation, and consequently generate contamination (dust) for production. Another big advantage of our design is that in closed position, the piston is flush with the...
Open the catalog to page 5DESCRIPTION OF OPERATIONS Fig.l CLOSED POSITION The piston is flush with the reactor or dryer, leaving no dead space (Fig.l). A perfect seal is formed directly by the piston (9) against the body of the valve. SAMPLING PROCEDURE Turn the handwheel counter clockwise to lower the piston (9) to its open position. While the product flows down into the sampling bottle (2), the operator can check the desired quantity of the product through the sight glass (1) (Fig.2). Turn the handwheel clockwise to bring back the piston (9) in its closed position. A firm Anal turn of the handwheel will give...
Open the catalog to page 6FAMAT ENGINEERED VALVES 125A STANDARD VALVEType 125A is the standard DN50 sampling valve by FAMAT. Used for sampling applications of powders, granules, pastes and liquids under process conditions in the pharmaceutical, chemical and food industries. MODEL NOMINAL SIZE MAX. TEMPERATURE: MIN. TEMPERATURE: PRESSURE CLASS: DESIGN PRESSURE: INT. ROUGHNESS: EXT. ROUGHNESS: APPL. STANDARD: BODY MATERIAL SEALS MATERIALS SAMPLE UNIT WEIGHT TECHNICAL DATA 125A DN 50 (2'') + 180°C/+356°F -10°C / + 14°F PN10 0-10 bar / 0-145 psi Ra <0.8 pm Ra <3.2 pm PED, ATEX, FDA Stainless steel 1.4435 (316L),...
Open the catalog to page 7FAMAT ENGINEERED VALVES 125TC TRI-CLAMP EASY-CLEAN VALVEThis sampling valve has one 2.5'' Tri-Clamp (TC) near the handwheel (Fig. 1). It is called easy-clean because the piston can be removed from the valve housing with minimal effort (Fig. 2), allowing Full cleaning of inner surfaces of the valve's body between batches. MODEL NOMINAL SIZE MAX. TEMPERATURE: MIN. TEMPERATURE: PRESSURE CLASS: DESIGN PRESSURE: INT. ROUGHNESS: EXT. ROUGHNESS: APPL. STANDARD: BODY MATERIAL SEALS MATERIALS SAMPLE UNIT WEIGHT TECHNICAL DATA 125TC DN 50 (2'') + 180°C/+356°F -10°C / + 14°F PN10 0-10 bar / 0-145...
Open the catalog to page 8FAMAT ENGINEERED VALVES 125CC CRUST BREAKING VALVE the risk of this the piston will This valve is used for products that could clog inside the dryer or vessel and block the piston. To eliminate impeding product flow into the sampling valve, FAMAT has developed the 125CC. With this type of valve, break the crust before the sample is taken. 1. Remove the security device 2. Turn the red handwheel clockwise to move the piston into the dryer to break the crust 3. Once the crust has been broken, proceed with the standard sampling by means of the black handwheel, to get the sample inside the...
Open the catalog to page 9FAMAT ENGINEERED VALVES 125OEL HIGH CONTAINMENT VALVE This new compact OEL High-Containment sampling device (Fig.1) enables the removal of the sample under contained conditions. The OEL (Occupational Exposure Limits) describes the maximum concentration of a hazardous substance which can be tolerated in the air of the production room without any negative effect to the health of the operator (Fig.2). OEB (Occupational Exposure Band): OEB4 1-10 jg/m3 NAME Bottle Venting valve Sight Glass Bottle Head Bottle Gasket Coupling Gasket O-ring O-Ring (2pcs) Body Piston Nut Screw Washer 2...
Open the catalog to page 10125OEL HIGH CONTAINMENT VALVE 2. PRE-SAMPLING • The sampling valve remains closed and the piston (9) • The handwheel (23) with an indicator position allows tightens without dead volume. to adjust the sample flow inside the volume V. This • Active (102) and passive (103) modules are joined and space must be only half-fllled (do not overflll). in closed position (lever 102a in closed position). • The purging valve (28) is closed. 3. SAMPLING TRANSFER TO THE BOTTLE 4. REMOVAL OF THE SAMPLING Open the purging valve (25) to equilibrate to atmospheric pressure in the outlet volume V....
Open the catalog to page 11FAMAT ENGINEERED VALVES 125AUT AUTOMATIC VALVEStandard sampling valve with a double acting pneumatic actuator. Proximity switch detects the open / closed position of the valve. Recommended spare parts Note: the size of the connection flanges is detailed at page 28.
Open the catalog to page 12FAMAT ENGINEERED VALVES 125M HIGH TEMPERATURE VALVE The 125M sampling valve is equipped with a metal piston (Stainless Steel, Hastelloy®) for sampling process up to 300°C (572° F). Unlike the PTFE or PEEK piston, the metal piston has a high temperature gasket around it. In order to keep the tightness, the gasket is retracting in a groove during the opening and closing operations of the valve. Only when the valve is completely closed by means of the final turn of the handwheel, the gasket will ensures sealing against the wall of the valve. Tightness from vacuum up to 10 bar (145 psi)....
Open the catalog to page 13All FAMAT catalogs and technical brochures
-
WATERWORK VALVES
60 Pages
-
Turbine (Bypass) Valves
12 Pages