Catalog excerpts
ENGINEERED VALVES SAMPLING VALVES TANK BOTTOM VALVES CHARGING VALVES □SWISS QUALITY
Open the catalog to page 1FAMAT SA is a Swiss engineering company for 40 FAMAT SA has today offices, distributors or agents years in the development and manufacturing of valves in most major countries in Europe, Middle-East, Asia and America. This global network allows us a close guarantee a full satisfaction at all levels of the supply cooperation with our customers and end-users, to Water Works Power Generation Petro-Chemical Founded in 1974, FAMAT SA is certified ISO 9001- 2008. Its procedures guarantee the best services in B - SAMPLING VALVES Pharmaceutical and Chemical compliance and on-time deliveries with...
Open the catalog to page 3ENGINEERED VALVES QUALITY CERTIFICATION & APPROVALS
Open the catalog to page 4PRODUCT RANGE HIGH CONTAINMENT HIGH TEMPERATURE NEAR INFRARED CRUST BREAKING HIGH CONTAINMENT DN15 METAL SEATED SAMPLING VALVE HORIZONTAL SAMPLING VALVE CRUST BREAKING TRICLAMP EASYCLEAN DN50 HORIZONTAL SAMPLING VALVE DN25 HORIZONTAL SAMLPING VALVE TANK BOTTOM VALVE CHARGING VALVE
Open the catalog to page 5FAMAT SAMPLING VALVE MAIN COMPONENTS HANDWHEEL HANDWHEEL CONNECTION FLANGE CONNECTION FLANGE NOSE NOSE PISTON PISTON O-RINGS O‐RINGS VENTING VALVE VENTING VALVE VALVE OUTLET VALVE OUTLET SAMPLING BOTTLE SAMPLING BOTTLE Simple design for maximum reliability & performance.
Open the catalog to page 6PATENTED FAMAT E.P. TECHNOLOGY Almost all FAMAT valves are based on our patented “EXPANDING PISTON TECHNOLOGY” . The patented system inside this piston allows the PTFE external coat to expand and insure a perfect tightness from vacuum up to full rating pressure 10 bar (145 psi). The advantage of having an expandable piston inside the valve is to eliminate the need for O-rings that can be damaged during valve operation, and consequently generate contamination (dust) for production. Another big advantage of our design is that In closed position, the piston will be flush with the connection...
Open the catalog to page 7CLOSED POSITION The piston is a flush fit to the reactor or dryer leaving no dead space (FIG. 1). A perfect seal is formed directly by the piston (9) against the body of the valve. SAMPLING PROCEDURE Turn the handwheel counter clockwise to lower the piston (9) to its open position. While the product flows 9 down into the sampling bottle (2), the operator can check the desired quantity of the product through the sight glass (1) ( FIG. 2 ). 2 1 FIG. 2 Turn the handwheel clockwise to bring back the piston (9) in its closed position. A firm final turn of the handwheel will give reliable sealing...
Open the catalog to page 8Type 125A is the standard DN50 sampling valve by FAMAT. Used for sampling applications of powders, granules, pastes and liquids under process conditions in the pharmaceutical, chemical and food industries. TECHNICAL DATA MODEL NOMINAL SIZE PRESSURE CLASS: DESIGN PRESSURE: APPL. STANDARD: BODY MATERIAL Stainless steel 1.4435 (316l), Hastelloy, Titanium etc SEALS MATERIALS Viton, Viton/FEP/PFA, Perfluorelastomer FFKM; EPDM (All FDA) SAMPLE UNIT Bottle 150 ml, glass Borosilicate with stainless steel protection Glass Bottle* Coupling Gasket Venting Valve * Recommended spare parts www.famat.com
Open the catalog to page 9This sampling valve has one Tri-Clamp (TC) 1.5’’ near the handwheel ( , FIG. 1 Called “EasyClean” the piston ). can be removed from the valve housing with a minimum of effort allowing full cleaning as shown on the picture ( FIG. 2 ). This permits a complete cleaning of internals between batches . TECHNICAL DATA MODEL NOMINAL SIZE PRESSURE CLASS: DESIGN PRESSURE: APPL. STANDARD: BODY MATERIAL Stainless steel 1.4435 (316l), Hastelloy, Titanium etc SEALS MATERIALS Viton, Viton/FEP/PFA, Perfluorelastomer FFKM; EPDM (All FDA) SAMPLE UNIT Bottle 150 ml, glass Borosilicate with stainless steel...
Open the catalog to page 10This valve is used for products which could clog inside the dryer or vessel and block the piston. To eliminate the risk of this impeding product flow in to the sampling valve, FAMAT has developed the 125CC (FIG. 1). With this kind of valve type, the crust will be broken by the piston before the sample is taken. CRUST BREAKING 1. Remove the security device. 2. Turn the red handwheel clockwise to move the piston into the dryer to break the crust as shown on the picture ( FIG. 2 ). 3. Once the crust has been broken, proceed with the standard sampling (page 4) with the black handwheel to get...
Open the catalog to page 11Standard sampling valve with a double acting pneumatic actuator ( FIG. 1 ). Proximity switch can be installed on valve to detect position. TECHNICAL DATA MODEL NOMINAL SIZE PRESSURE CLASS: DESIGN PRESSURE: APPL. STANDARD: BODY MATERIAL Stainless steel 1.4435 (316l), Hastelloy, Titanium etc SEALS MATERIALS Viton, Viton/FEP/PFA, Perfluorelastomer FFKM; EPDM (All FDA) SAMPLE UNIT Bottle 150 ml, glass Borosilicate with stainless steel protection ACTUATOR DESCRIPTION Double Acting Pneuamtic Actuator – Aluminium Body Operating pressure: 0.6 to 12 bar Design Operating pressure: 6 bar G 1/8” air...
Open the catalog to page 12125OEL HIGH CONTAINMENT This new compact OEL High-Containment sampling device (FIG. 1) allows the removal of a product sampled under contained conditions. The OEL (Occupational Exposure Limits) describes the maximum concentration of a drug substance which can be tolerated in the air of the production room without any negative effect to the health of the operators (FIG. 2). (OEL) level range : 1-10μg / m3 (without aspiration) TECHNICAL DATA MODEL NOMINAL SIZE APPL. STANDARD: PRESSURE CLASS: DESIGN PRESSURE: BODY MATERIAL Stainless steel 1.4435 (316l), Hastelloy, Titanium etc SEALS...
Open the catalog to page 13The sampling valve remains closed piston 9 tightens without dead volume. to adjust the sample flow inside the volume V. This Active (102) and passive (103) module are joined space must be only half-filled (do not overfill). All cleaning valves (25, 26, 27 28 and 29) are closed. , and in closed position (lever 102a in closed position). 3 - SAMPLING TRANSFER IN BOTTLE • Open the purging valve (25) to equilibrate to atmos- The joined active + passive modules (102+103) are gravity in the sampling bottle (3). Outlet of sampling valve closed by the activemodule (102) (max. allowable pressure 6...