video corpo

TEST CHAMBERS

TEST CHAMBERS
1 / 24 PagesView full catalog

TEST CHAMBERS

Product catalog summary
Overview: The document provides detailed information on various types of test chambers offered by Falc Instruments, including climatic, stability, and growth test chambers. These chambers are designed to simulate environmental conditions for testing purposes across different industries.
Climatic Test Chambers: These chambers are available with vertical airflow and can be configured with or without humidity control. They are used in industries such as food, pharmaceuticals, and electronics. Key features include a temperature range from +4°C to +60°C, optional lower temperatures, and humidity control from 20% to 90% RH. Standard features include a cooling system, safety thermostat, and touchscreen controller.
Stability Test Chambers: Designed for horizontal airflow, these chambers are suitable for laboratory testing, quality tests, and ICH tests in the pharmaceutical industry. They offer similar temperature and humidity ranges as climatic chambers and include features like a touchscreen controller and independent cooling and heating systems.
Growth Test Chambers: These chambers support both vertical and horizontal airflow configurations and are available with or without humidity control. They are equipped with lighting options on the door and sides, making them suitable for applications requiring controlled growth conditions.
Specifications and Features: All chambers feature high-density polyurethane insulation, stainless steel finishes, and are equipped with USB ports for data storage. Optional accessories include UV light tubes, GSM phone alarm modules, and battery backups. The chambers are customizable based on specific testing requirements.
Applications: The test chambers are used in various fields, including the automotive, construction materials, biotechnology, and textile industries. They are essential for conducting resistance tests, material testing, and simulating environmental conditions for product development and quality assurance.
Configuration and Customization: Falc Instruments offers customization options to meet specific testing needs. Customers are encouraged to work with the technical team to configure the chambers according to their application requirements, ensuring optimal performance and accurate simulation of environmental conditions.
Stability Tests: Essential for assessing product shelf life and efficiency by replicating long-term effects in a short time frame. Includes tests for physical, microbiological, and chemical variations.
Test Chambers Configuration: Customizable based on the specific requirements of the test, including temperature, humidity, and light conditions. Technical support is available for designing suitable chambers.
Forced Air Growth Test Chambers: Used for plant growth, seed germination, and other applications requiring controlled environmental conditions. Available with vertical and horizontal airflow, with or without humidity control.
Specifications: Chambers offer a temperature range from +4°C to +60°C, with optional ranges down to -30°C. Humidity control ranges from 20% to 90% RH. Features include touchscreen controllers, programmable settings, and safety mechanisms.
Applications: Suitable for various industries, including chemical, pharmaceutical, cosmetic, and biotechnology. Specific applications include plant growth, insect incubation, and tissue culture.
Optional Accessories: Include UV light tubes, telescopic trays, GSM phone alarm modules, and battery backups for enhanced functionality.
Configuration Guidance: Emphasizes the importance of configuring chambers based on specific testing needs, with a focus on temperature, humidity, and lighting conditions.
Conclusion: The document provides comprehensive information on the design and application of test chambers for stability testing in various industries, highlighting the importance of customization and technical support in achieving accurate testing results.
See more

Catalog excerpts

TEST CHAMBERS-1

test chambers Climatic Test Chambers Stability Test Chambers Growth Test Chambers

 Open the catalog to page 1
TEST CHAMBERS-3

TEST CHAMBERS 5 I CLIMATIC TEST CHAMBERS 6 I Climatic Chambers with and without humidity control Vertical Airflow 11 12 12 STABILITY TEST CHAMBERS Stability Chambers with and without humidity control Horizontal Airflow Stability Chambers with and without humidity control Horizontal Airflow for ICH Test FORCED AIR GROWTH TEST CHAMBERS Growth Chambers with and without humidity control Vertical and Horizontal Airflow Application table

 Open the catalog to page 3
TEST CHAMBERS-4

CLIMATIC TEST CHAMBERS CLIMATIC TEST CHAMBERS - VERTICAL AIRFLOW • Without humidity (FCC Series) • With humidity (FCC-H Series) STABILITY TEST CHAMBERS STABILITY TEST CHAMBERS - HORIZONTAL AIRFLOW • Without humidity - FSC Series - FSC For ICH Test Series • With humidity FSC-H Series - FSC-H For ICH Test Series FORCED AIR GROWTH TEST CHAMBERS GROWTH TEST CHAMBERS - VERTICAL AIRFLOW • Without humidity - Light on the door (GVD Series) - Lights on the door and two sides (GVS Series) • With humidity - Light on the door (GVD-H Series) - Lights on the door and two sides (GVS-H Series) GROWTH TEST CHAMBERS...

 Open the catalog to page 4
TEST CHAMBERS-5

CLIMATIC TEST CHAMBERS 6 6 TEST CHAMBERS CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control Vertical Airflow

 Open the catalog to page 5
TEST CHAMBERS-6

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow Food industry Confectionary industry Laboratory testing Analytical laboratory Pharmaceutical industry Quality test Environmental test Construction materials industry Calibration laboratory Biotechnology Texile industry Automotive industry Electronic industry Plastic industry Optionally -10°/-20°/-30°C to +60°C without humidity control CLIMATIC TEST CHAMBERS VERTICAL AIRFLOW Without Humidity With Hum

 Open the catalog to page 6
TEST CHAMBERS-7

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow STANDARD FEATURES • • • • Cooling system controller by solenoid electrovalves Adjustable safey thermostat to protect the samples System setting protected by password Key lock on the door Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Models include forced air refrigeration (distributed uniformly vertically), and have high temperature homogeneity inside of the chamber Ultrasound humidity generator, introducing microscopic water drops inside of the...

 Open the catalog to page 7
TEST CHAMBERS-8

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow FCC/FCC-H 940 FCC/FCC-H 1500 FCC/FCC-H 2200 Capacity Lt 350 Nr of shelves 2 Nr max of shelves 4 1 Nr of doors Compressor RH 1/2 Usable Internal Dimensions (WxDxH) mm 820x540x660 External dimensions (WxDxH) mm 925x800x1140 Climatic Chamber - Vert. Airflow without Humidity FCC 701.1100.01 Climatic Chamber - Vert. Airflow with Humidity FCC-H 701.1101.01 TEST CHAMBERS

 Open the catalog to page 8
TEST CHAMBERS-9

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow OPTIONAL ACCESSORIES • • • • • Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Humidity generator up to +95°C RH Air drying system up to 15% RH at +4°C Additional access ports to introduce cables and probes Thermal glass door, with heated frame in models with humidity control or lower temperatures External stainless steel finish Plugs inside of the chamber Potential free output for remote alarm control UV light tubes for sterilization Telescopic...

 Open the catalog to page 9
TEST CHAMBERS-10

HOW TO CONFIGURE FALC CLIMATIC TEST CHAMBERS Falc Test Chambers are suitable for creating environmental conditions to test samples by combining three variables: temperature, humidity and lights. Considering the many combinations of these variables, we suggest you to directly configure the instrument with the manufacturer, providing all the necessary information, including the application and the mode of use. The temperature and the humidity of both Climatic Chambers and Stability Chambers need a close attention: Just as the temperature can reach -30 ºC, requiring a specific refrigeration system,...

 Open the catalog to page 10
TEST CHAMBERS-11

STABILITY TEST CHAMBERS 12 12 12 STABILITY TEST CHAMBERS Stability Chambers with and without humidity control Horizontal Airflow Stability Chambers with and without humidity control Horizontal Airflow for ICH Test

 Open the catalog to page 11
TEST CHAMBERS-12

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow Laboratory testing Quality test Chemical industry Environmental test Food industry HORIZONTAL AIRFLOW FSC SERIES Optionally -10°/-20°/-30°C to +60°C without humidity control Touchscreen controller included Stability Chambers with and without humidity control - Horizontal Airflow for ICH Test FIELDS OF APPLICATION: Long term testing at +25°C / 60% RH or +30°C / 65% RH Pharmaceutical industry with ICH test Laboratory testing Quality test Chemical industry Environmental test Food industry Cosmetic industry...

 Open the catalog to page 12
TEST CHAMBERS-13

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow STANDARD FEATURES • • • • Cooling system controller by solenoid electrovalves Adjustable safey thermostat to protect the samples System setting protected by password Key lock on the door Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Models include forced air refrigeration (distributed uniformly vertically), and have high temperature homogeneity inside of the chamber Ultrasound humidity generator, introducing microscopic water drops inside of...

 Open the catalog to page 13
TEST CHAMBERS-14

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow 500 - 700 - 940 lt Capacity FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for ICH Test ICH Test ICH Test ICH Test ICH Test ICH Test 350 500 700 940 1500 2200 Capacity Lt 350 500 700 940 1500 2200 Nr of shelves 2 3 4 4 4+4 4+4 Nr max of shelves 4 6 8 8 8+8 8+8 Nr of doors 1 1 1 1 2 2 Compressor RH 1/2 3/8 3/8 3/8 3/8 3/8 Usable dimensions (WxDxH) mm 820x540x660 640x600x1100 640x600x1350 640x890x1350 1500x600x1350...

 Open the catalog to page 14

All FALC Instruments S.r.l. catalogs and technical brochures

  1. Autoclaves_2024

    20  Pages

  2. FURNACES

    8  Pages

  3. THERMOBLOCKS

    12  Pages

  4. STIRRERS

    20  Pages

  5. THERMOCYCLERS

    8  Pages

  6. HEATERS

    16  Pages

  7. PHMETERS

    32  Pages

Archived catalogs

  1. AUTOCLAVES

    16  Pages

  2. INCUBATORS

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.