TEST CHAMBERS
24Pages

{{requestButtons}}

Catalog excerpts

TEST CHAMBERS - 1

test chambers Climatic Test Chambers Stability Test Chambers Growth Test Chambers

Open the catalog to page 1
TEST CHAMBERS - 3

TEST CHAMBERS 5 I CLIMATIC TEST CHAMBERS 6 I Climatic Chambers with and without humidity control Vertical Airflow 11 12 12 STABILITY TEST CHAMBERS Stability Chambers with and without humidity control Horizontal Airflow Stability Chambers with and without humidity control Horizontal Airflow for ICH Test FORCED AIR GROWTH TEST CHAMBERS Growth Chambers with and without humidity control Vertical and Horizontal Airflow Application table

Open the catalog to page 3
TEST CHAMBERS - 4

CLIMATIC TEST CHAMBERS CLIMATIC TEST CHAMBERS - VERTICAL AIRFLOW • Without humidity (FCC Series) • With humidity (FCC-H Series) STABILITY TEST CHAMBERS STABILITY TEST CHAMBERS - HORIZONTAL AIRFLOW • Without humidity - FSC Series - FSC For ICH Test Series • With humidity FSC-H Series - FSC-H For ICH Test Series FORCED AIR GROWTH TEST CHAMBERS GROWTH TEST CHAMBERS - VERTICAL AIRFLOW • Without humidity - Light on the door (GVD Series) - Lights on the door and two sides (GVS Series) • With humidity - Light on the door (GVD-H Series) - Lights on the door and two sides (GVS-H Series) GROWTH TEST...

Open the catalog to page 4
TEST CHAMBERS - 5

CLIMATIC TEST CHAMBERS 6 6 TEST CHAMBERS CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control Vertical Airflow

Open the catalog to page 5
TEST CHAMBERS - 6

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow Food industry Confectionary industry Laboratory testing Analytical laboratory Pharmaceutical industry Quality test Environmental test Construction materials industry Calibration laboratory Biotechnology Texile industry Automotive industry Electronic industry Plastic industry Optionally -10°/-20°/-30°C to +60°C without humidity control CLIMATIC TEST CHAMBERS VERTICAL AIRFLOW Without Humidity With Hum

Open the catalog to page 6
TEST CHAMBERS - 7

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow STANDARD FEATURES • • • • Cooling system controller by solenoid electrovalves Adjustable safey thermostat to protect the samples System setting protected by password Key lock on the door Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Models include forced air refrigeration (distributed uniformly vertically), and have high temperature homogeneity inside of the chamber Ultrasound humidity generator, introducing microscopic water drops inside of...

Open the catalog to page 7
TEST CHAMBERS - 8

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow FCC/FCC-H 940 FCC/FCC-H 1500 FCC/FCC-H 2200 Capacity Lt 350 Nr of shelves 2 Nr max of shelves 4 1 Nr of doors Compressor RH 1/2 Usable Internal Dimensions (WxDxH) mm 820x540x660 External dimensions (WxDxH) mm 925x800x1140 Climatic Chamber - Vert. Airflow without Humidity FCC 701.1100.01 Climatic Chamber - Vert. Airflow with Humidity FCC-H 701.1101.01 TEST CHAMBERS

Open the catalog to page 8
TEST CHAMBERS - 9

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow OPTIONAL ACCESSORIES • • • • • Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Humidity generator up to +95°C RH Air drying system up to 15% RH at +4°C Additional access ports to introduce cables and probes Thermal glass door, with heated frame in models with humidity control or lower temperatures External stainless steel finish Plugs inside of the chamber Potential free output for remote alarm control UV light tubes for sterilization...

Open the catalog to page 9
TEST CHAMBERS - 10

HOW TO CONFIGURE FALC CLIMATIC TEST CHAMBERS Falc Test Chambers are suitable for creating environmental conditions to test samples by combining three variables: temperature, humidity and lights. Considering the many combinations of these variables, we suggest you to directly configure the instrument with the manufacturer, providing all the necessary information, including the application and the mode of use. The temperature and the humidity of both Climatic Chambers and Stability Chambers need a close attention: Just as the temperature can reach -30 ºC, requiring a specific refrigeration...

Open the catalog to page 10
TEST CHAMBERS - 11

STABILITY TEST CHAMBERS 12 12 12 STABILITY TEST CHAMBERS Stability Chambers with and without humidity control Horizontal Airflow Stability Chambers with and without humidity control Horizontal Airflow for ICH Test

Open the catalog to page 11
TEST CHAMBERS - 12

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow Laboratory testing Quality test Chemical industry Environmental test Food industry HORIZONTAL AIRFLOW FSC SERIES Optionally -10°/-20°/-30°C to +60°C without humidity control Touchscreen controller included Stability Chambers with and without humidity control - Horizontal Airflow for ICH Test FIELDS OF APPLICATION: Long term testing at +25°C / 60% RH or +30°C / 65% RH Pharmaceutical industry with ICH test Laboratory testing Quality test Chemical industry Environmental test Food industry Cosmetic...

Open the catalog to page 12
TEST CHAMBERS - 13

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow STANDARD FEATURES • • • • Cooling system controller by solenoid electrovalves Adjustable safey thermostat to protect the samples System setting protected by password Key lock on the door Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Models include forced air refrigeration (distributed uniformly vertically), and have high temperature homogeneity inside of the chamber Ultrasound humidity generator, introducing microscopic water drops inside...

Open the catalog to page 13
TEST CHAMBERS - 14

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow 500 - 700 - 940 lt Capacity FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for ICH Test ICH Test ICH Test ICH Test ICH Test ICH Test 350 500 700 940 1500 2200 Capacity Lt 350 500 700 940 1500 2200 Nr of shelves 2 3 4 4 4+4 4+4 Nr max of shelves 4 6 8 8 8+8 8+8 Nr of doors 1 1 1 1 2 2 Compressor RH 1/2 3/8 3/8 3/8 3/8 3/8 Usable dimensions (WxDxH) mm 820x540x660 640x600x1100 640x600x1350 640x890x1350...

Open the catalog to page 14

All FALC Instruments S.r.l. catalogs and technical brochures

  1. INCUBATORS

    20 Pages

  2. FURNACES

    8 Pages

  3. THERMOBLOCKS

    12 Pages

  4. AUTOCLAVES

    16 Pages

  5. STIRRERS

    20 Pages

  6. HEATERS

    16 Pages

  7. PHMETERS

    32 Pages