The document provides comprehensive details on autoclaves by Falc Instruments, focusing on specifications, safety features, and operational procedures for both bench top and vertical models, used in medical and laboratory environments.
Bench Top Autoclaves
  • Class N Autoclaves: Designed for sterilizing unwrapped materials without cavities, featuring pre-set cycles at 121°C and 134°C, a safety thermostat, and a certified safety valve. The chamber is made of AISI 304 stainless steel with a maximum load of 5 kg per cycle.
  • Class B Autoclaves: Suitable for both wrapped and unwrapped materials, including porous and hollow bodies. They offer multiple pre-set cycles, including a "flash" cycle for quick sterilization and a "prion" cycle for specific diseases, with features like a PID microprocessor and automatic barometric alignment.
Vertical Autoclaves
  • Routine Applications: Models like the ATV 80 are designed for routine sterilization of solids and liquids, featuring over-temperature protection and a microcomputer control system.
  • High-Performing Models: Models such as the ATV 600/850/1100 include advanced features like drying cycles, automatic water filling, and multiple safety devices, suitable for sterilizing solid and liquid materials, including medical waste.
Mandatory Tests
Class B autoclaves require mandatory tests such as the Helix Test, Bowie & Dick Test, and various chemical and biological integrators to ensure sterilization efficiency and safety.
Accessories
A variety of accessories are available, including stainless steel baskets, printers, and sterilization effectiveness strips, to enhance autoclave functionality and monitoring.
Comparison
The document compares horizontal and vertical autoclave models, detailing capacities, power ratings, and specific features to assist in selecting the appropriate model for different applications.
Technical Specifications and Features
  • Temperature Settings: 96°C for solid, 79°C for liquid.
  • Cycle Types: Solid cycle, Liquid cycle, Liquid and warming cycle, Agar cycle, Solid with drying cycle, Medical waste cycle, Customized cycles.
  • Optional Features: Printer, liquid sensor printer.
Vertical Autoclaves Comparison
  • Model: ONE
  • Seal Length: 320 mm
  • Seal Width: 12 mm
  • External Dimensions: 460x400x170 mm
  • Power: 320 W
  • Weight: 8 Kg
  • Code: 638.1434.40
  • Voltage/Frequency: 220-240/50-60
  • Safety Class: 3.1
  • Protection Class: 30
Accessories and Spare Parts
  • T-Paper: Flat sterilization reels for various uses including hospital, medical, dental, cosmetic, veterinary, and podology.
  • Cartridge Heater: Code 638.1434.42
  • Pipe Lengths: 200 m with diameters of 75, 100, 150, 200, 250 mm.
  • Codes for Pipes: 638.1435.07, 638.1435.10, 638.1435.15, 638.1435.20, 638.1435.25
Additional Features
  • Sealing Capability: Suitable for all types of paper for sterilization, including folded paper.
  • Digital Control: Includes a signal for bad sealing.
  • Maximum Seal Length: 320 mm
  • Maximum Seal Width: 12 mm
Contact Information
FALC INSTRUMENTS s.r.l.
Via G. M. Compagnoni, 2
24047 Treviglio (BG) - Italy
Phone: +39 0363 304660
Email: [email protected]
Website: www.falcinstruments.it
See more

Catalog excerpts

AUTOCLAVES-3

BENCH TOP AUTOCLAVES Class N Autoclaves - medical devices Class B Autoclaves - medical devices Mandatory test for autoclave ATV 50 - Class B Horizontal autoclaves comparison VERTICAL AUTOCLAVES Small autoclave for routine applications High-performing autoclaves with drying Accessories Autoclaves for routine applications Vertical autoclaves comparison

 Open the catalog to page 3
AUTOCLAVES-4

BENCH TOP AUTOCLAVES Class N Autoclaves - medical devices Class N sterilization: unwrapped materials without cavities. General purpose, simple sterilization for laboratories. Pre-set cycles: • 121°C cycle: for solid and ferrous materials (unwrapped); • 134°C cycle: for solid and ferrous materials (unwrapped). Technical data Capacity Filling tank capacity Filling water Dimensions (LxWxH) Chamber dimensions (Dia*H) Chamber material Opened door dimensions Rated Power Max sterilization temperature Max working pressure Max vacuum Number of supplied trays Tray material Tray dimensions (LxWxH) Weight...

 Open the catalog to page 4
AUTOCLAVES-5

BENCH TOP AUTOCLAVES Class B Autoclaves - medical devices Class B sterilization: wrapped and unwrapped materials (cannulas, tubes or devices with small passages): • porous bodies: simple and compound materials that soak up fluids (tissues, gowns, surgical gauzes, dressing, etc...); • hollow bodies: materials, device and obstructions with small cavities. Pre-set cycles: • 121°C cycle: for thermoplastic, hallow bodies, solid and ferrous materials (wrapped and unwrapped); • 134°C classic cycle: for solid and ferrous materials (wrapped and unwrapped); • 134°C “flash” cycle for quick sterilization...

 Open the catalog to page 5
AUTOCLAVES-6

MANDATORY TEST FOR AUTOCLAVE ATV 50 – CLASS B The user of a medical device must periodically check its efficiency according to procedures established by directives, standards or guidelines. SteamPlus Chemical integrators VaporLine Chemical integrators B Test Plus Biological test Helix Test Physical test used to assess the capacity of steam penetration in hollow objects. Physical test used to assess the capacity of steam penetration in porous objects. The chemical integrators are more suitable devices for the control of steam sterilization, as they interact with all the cycle parameters (temperature,...

 Open the catalog to page 6
AUTOCLAVES-7

HORIZONTAL AUTOCLAVES COMPARISON Features tables ATV 20 HYDRA EVO CLASS N Included printer Manually operated door Deionization connection Night cycle PID microprocessor Automatic barometric alignment system Sterilization cycles table 121°C unwrapped Technical data Capacity Filling tank capacity Filling water Dimensions (LxWxH) Chamber dimensions (Dia*H) Chamber material Opened door dimensions Rated Power Max sterilization temperature Max working pressure Max vacuum Number of supplied trays Tray material Tray dimensions (LxWxH) Weight Medical class Code ATV 20 HYDRA EVO CLASS N ATV 50 EUROPA B...

 Open the catalog to page 7
AUTOCLAVES-8

VERTICAL AUTOCLAVES Small autoclave for routine applications Vertical loading autoclave for routine applications Sterilization cycles: • 4 pre-set cycles: 121°C - 135°C cycles for unwrapped solid and liquids • 1 customized cycle Pressure safety valve preset to 3 bar Over temperature protection Temperature monitoring Over current and short circuit protection Electric leakage protection Anti-scald chamber cover and bench Automatic troubleshooting Safety devices: mechanical lock to insert before starting the cycle Microcomputer control system monitors sterilization process. Saturated steam monitoring...

 Open the catalog to page 8
AUTOCLAVES-9

VERTICAL AUTOCLAVES High-performing autoclaves with drying Microcomputer control system monitors sterilization process, maintenance, calibration, traceability and recording. Saturated steam monitoring creates a sterilization envronment and discharges the steam Vertical loading autoclave for solid and liquid materials Sterilization cycles: • Solid cycle • Liquid cycle • Liquid and warming cycle • Agar cycle • Solid with drying cycle • Medical waste cycle • Customized cycle Dry scorch protection Over pressure protection Safety valve Water level sensor Over temperature protection Temperature monitoring...

 Open the catalog to page 9
AUTOCLAVES-10

ACCESSORIES ACCESSORIES INCLUDED Stainless steel baskets Code The diameter and the height of the baskets can be customized OPTIONAL ACCESSORIES Load thermometer (Liquid temperature sensor) Code 608.1002.62 Printer paper (2 rolls) Code 608.1002.63 Stainless steel pail 5 printing sets (pressure sensor + printer) Code 608.1002.65

 Open the catalog to page 10
AUTOCLAVES-11

VERTICAL AUTOCLAVES Autoclaves for routine applications Vertical loading autoclave for solid and liquid materials Pre-set cycles: • Solid cycle • Liquid cycle Dry scorch protection Over pressure protection Safety valve Over temperature protection Over current and short circuit protection Electric leakage protection Anti-scald chamber cover and bench Automatic troubleshooting with 13 error detection procedures 2 safety devices: • Self-induction interlocking device to avoid misuse • Safety pressure lid locking Microcomputer control system Automatic cold air discharging monitoring to guarantee pure...

 Open the catalog to page 11
AUTOCLAVES-12

VERTICAL AUTOCLAVES COMPARISON Slide (left to right) Design Pressure Waste Mode Agar Mode Drying Mode Fully automatic Automatic Water Feeding Safety Features Dry scorch protection, Over pressure protection, Safety valve, Water lever sensor, Over temperature protection, Temperature monitor, Automatic troubleshooting, Anti-scald chamber cover and bench, Over current and short circuit protection, Electric leakage protection, Cooling lid lock, Mechanical lock, Electric double inner lock Dry scorch protection, Over pressure protection, Safety valve, Over temperature protection, Automatic troubleshooting,...

 Open the catalog to page 12
AUTOCLAVES-13

THERMOSEALER Useful to seal all types of paper for sterilization, including folded paper Digital control Signal of bad sealing The maximum seal lenght is 320 mm The maximum seal width is 12 mm ONE SPARE PARTS cartridge heater Code 638.1434.42 Technical data Seal lenght Seal width External dimensions LxWxH Power Weight Code T-Paper: flat sterilization reels are designed for hospital, medical, dental, cosmetic, veterinary and podology uses and for all steam and gas sterilization processes. Diameter Code

 Open the catalog to page 13

All FALC Instruments S.r.l. catalogs and technical brochures

  1. Autoclaves_2024

    20  Pages

  2. FURNACES

    8  Pages

  3. THERMOBLOCKS

    12  Pages

  4. STIRRERS

    20  Pages

  5. TEST CHAMBERS

    24  Pages

  6. THERMOCYCLERS

    8  Pages

  7. HEATERS

    16  Pages

  8. PHMETERS

    32  Pages