sealed instrument designed to perform a sterilization process, i.e., the complete elimination of microorganisms present on a specific object or solution, through the increase in temperature and pressure within the chamber. Sterilization using pressurized steam is currently the safest sterilization method and involves a working cycle consisting of several phases: • Vacuum (generation) • Heating • Sterilization • Cooling This method is mainly used in work environments dedicated to pharmaceutical production, healthcare activities, dental practices, as well as in chemical and microbiological laboratories,...
Open the catalog to page 2Class N autoclaves Medical devices for unwrapped tools Class B autoclaves - medical devices for wrapped and unwrapped tools mandatory test for autoclave ATV 50 class B horizontal autoclaves comparison floor standing autoclaves for solids and liquids Vertical autoclaves with small volume Standard vertical autoclaves with large volume Full-optional vertical autoclaves with large volume vertical autoclaves comparison
Open the catalog to page 3bench-top autoclaves S M A L L-S IZED AUTOCLAVES WI TH HO R I ZO NTA L LOA D I NG FO R SO L I D S Autoclaves for unwrapped tools ATV 20: Class N autoclave suitable for sterilizing non-packaged tools, devoid of cavities. Autoclaves for wrapped and unwrapped tools ATV 50: Class B autoclave suitable for sterilizing wrapped and unwrapped tools, from porous to fabric and hollow bodies. This instrument uses air extraction even from small cavities (fractional vacuum).
Open the catalog to page 4floor standing autoclaves VERTI CA L AU TO C L AV ES FO R SO L I D S A ND L I Q UID S small volumes autoclaves The ATV 80 model represents the perfect balance between compactness and efficiency with its 24-liter chamber. This vertically loaded autoclave is mainly used for routine applications with linear cycles on solids and liquids. large volumes autoclaves STANDARD MODELS FULL - OPTIONAL MODELS ATV-E 500/800/1000: These models have a simple structure with linear working cycles for solids and liquids ensuring excellent sterilization, efficiency, and reliability. ATV 600/850/1100: Models with...
Open the catalog to page 5bench top autoclaves C L ASS N AUTOCLAVES M E DI CA L DEVICES FOR UN WRAPP E D TO O LS Class N sterilization: unwrapped materials without cavities. General purpose, simple sterilization for laboratories. Pre-set cycles: • 121°C cycle: for solid and ferrous materials (unwrapped); 134°C cycle: for solid and ferrous materials (unwrapped). Protected tray holder to safeguard against contact between load and chamber. Safety thermostat. ATV 20 Tray support to prevent contact between the load and the chamber. Certified safety valve. 3 safety devices on the door: • mechanic and electro-magnetic device:...
Open the catalog to page 6bench top autoclaves C L ASS B AUTOCLAVES M E DI CA L DEVICES FOR WRAP P ED AND U NW R AP P E D TO O LS Class B sterilization: wrapped and unwrapped materials (cannulas, tubes or devices with small passages): • porous bodies: simple and compound materials that soak up fluids (tissues, gowns, surgical gauzes, dressing, etc...); hollow bodies: materials, device and obstructions with small cavities. Pre-set cycles: 121°C cycle: for thermoplastic, hallow bodies, solid and ferrous materials (wrapped and unwrapped); 134°C classic cycle: for solid and ferrous materials (wrapped and unwrapped); 134°C...
Open the catalog to page 7Mandatory test for autoclave ATV 50 – class B The user of a medical device must periodically check its efficiency according to procedures established by directives, standards or guidelines. SteamPlus Chemical integrators VaporLine Chemical integrators B Test Plus Biological test Helix Test Bowie & Dick Physical test used to assess the capacity of steam penetration in hollow objects. Physical test used to assess the capacity of steam penetration in porous objects. The chemical integrators are more suitable devices for the control of steam sterilization, as they interact with all the cycle parameters...
Open the catalog to page 8horizontal autoclaves comparison FEATURES TABLES ATV 20 HYDRA EVO CLASS N Included printer Manually operated door Deionization connection Night cycle PID microprocessor Automatic barometric alignment system STERILIZATION CYCLES TABLE 121°C unwrapped ATV 20 HYDRA EVO CLASS N ATV 50 EUROPA B EVO CLASS B Technical data Capacity lt Filling tank capacity lt Filling water Dimensions (LxWxH) mm Chamber dimensions (Dia*H) mm Chamber material Opened door dimensions mm Rated Power kW Max sterilization temperature °C Max working pressure bar Max vacuum Number of supplied trays Tray material Tray dimensions...
Open the catalog to page 9floor standing autoclaves for solids and liquids V E RTI CA L AUTOCLAVES WIT H SM AL L VO LU M E Vertical loading autoclave for routine applications Sterilization cycles: • 4 pre-set cycles: 121°C - 135°C cycles for unwrapped solid and liquids • 1 customized cycle Pressure safety valve preset to 3 bar Over temperature protection Temperature monitoring Over current and short circuit protection Electric leakage protection Anti-scald chamber cover and bench Automatic troubleshooting Safety devices: mechanical lock to insert before starting the cycle Microcomputer control system monitors sterilization...
Open the catalog to page 104 sheels for easy movement with brakes ACCESSORIES INCLUDED OPTIONAL ACCESSORIES Steriscan Strip for measuring the effectiveness of the sterilizartion (pack 250) Code 608.1000.05 Tank included to exhaust steam GREEN PAPER FOR STERILIZATION Code SPARE PARTS Stainless steel AISI 304. Size Ø240xH430 mm Not divisible paper for printer 10 pcs pack
Open the catalog to page 11floor standing autoclaves for solids and liquids STANDA R D V ERT ICAL AUTOCLAVES W I T H L AR G E VO LU M E Vertical loading autoclave for solid and liquid materials Pre-set cycles: • Solid cycle • Liquid cycle Dry scorch protection Over pressure protection Safety valve Over temperature protection Over current and short circuit protection Electric leakage protection Anti-scald chamber cover and bench Automatic troubleshooting with 13 error detection procedures 2 safety devices: • Self-induction interlocking device to avoid misuse • Safety pressure lid locking Microcomputer control system Automatic...
Open the catalog to page 124 Pages
8 Pages
16 Pages
24 Pages
8 Pages
8 Pages
12 Pages
20 Pages
24 Pages
8 Pages
16 Pages
32 Pages
130 Pages
12 Pages
20 Pages
16 Pages
20 Pages
20 Pages
20 Pages