1. Catalogs
  2. FAIP
  3. FORCED AIR SPACE HEATERS

FORCED AIR SPACE HEATERS

FORCED AIR SPACE HEATERS
1 / 86 PagesView full catalog

FORCED AIR SPACE HEATERS

Product catalog summary
Overview: The document is a catalog for the 2014/15 range of mobile space heaters, detailing specifications, features, and accessories for infrared, direct combustion, and indirect combustion models.
Infrared Space Heaters: These heaters provide direct heat through radiation, minimizing noise. Key features include a BM2 burner, electronic flame control, and compatibility with various control devices. The combustion chamber is made of AISI 430 stainless steel, enhancing durability and cooling efficiency.
Direct Combustion Mobile Space Heaters: Equipped with an automatic oil burner and electronic flame control, these heaters are designed for easy integration with control devices. They feature a stainless steel combustion chamber and offer post-ventilation cooling. Fuel tanks vary by model.
Indirect Combustion Mobile Space Heaters: These models include an automatic oil burner and are compatible with control devices. They feature stainless steel combustion chambers and aluminized steel heat exchangers, achieving up to 90% efficiency in certain models.
Accessories: The catalog lists optional accessories like fuel level gauges, pre-heated fuel filters, and connection kits, enhancing heater functionality.
Technical Specifications: Specifications include heat power, efficiency, air flow, fuel consumption, and electrical requirements, along with dimensions and weights for transport.
PHOEN Indirect Combustion Portable Heaters: Features a BM2 burner with two-stage power settings, stainless steel construction, and multiple thermostats for control.
JUMBO Heavy-Duty Mobile Space Heaters: Available with various burner options, these heaters feature double-skinned bodies for insulation and multiple fan options.
Protection Kits: JUMBO SCUDO kits provide reinforced bases and protective covers, enhancing safety and durability.
Electrical Heaters: The EK series offers adjustable installation and high-strength resistances, with built-in thermostats and stainless steel grids.
Compliance and Safety: Heaters conform to safety standards, featuring safety thermostats and electronic flame control.
Procedures and Controls: Automatic ignition and flame monitoring ensure safe operation, with options for ventilation and control interfaces.
Standards and Compliance: Heaters meet UNI EN 12669:2003 standards, ensuring European safety compliance.
Performance Data: Models offer varying heat outputs and efficiencies, with detailed specifications for air flow and power consumption.
Weights and Dimensions: Detailed dimensions and weights are provided for installation planning.
Product Specifications: Includes duct adapters, oil tanks, and air outlets with specific dimensions and weights.
Formulas and Equivalences: Provides formulas for heating power calculation and conversion factors for various measurements.
Equipment: Lists tools and devices for measuring and maintaining heaters, such as test sets and thermometers.
Contact Information: FAIP SRL contact details and branch locations in Italy are provided.
See more

Catalog excerpts

FORCED AIR SPACE HEATERS-1

GENERATOR I Dl ARIA CALDA . > FORCED AIR SPACE HEATERS

 Open the catalog to page 1
FORCED AIR SPACE HEATERS-2

www.FAIP.IT [email protected] GENERATORI MOBILI A RAGGI INFRAROSSI INFRARED SPACE HEATERS

 Open the catalog to page 2
FORCED AIR SPACE HEATERS-3

Flusso diretto di calore per irraggiamento senza movimentazione d’aria Basso livello di rumore Bruciatore BM2 dedicato con componentistica UE standard (vedere pag. 26) Pompa gasolio ad ingranaggi Controllo elettronico di fiamma con fotoresistenza Possibilità di interfaccia con termostato, umidostato o timer Cavo alimentazione elettrica (1,5 m) con spina Camera di combustione in acciaio inox AISI 430 Raffreddamento involucro esterno mediante aria forzata su tutta la superficie del cono Post-ventilazione temporizzata di raffreddamento della camera di combustione Tubi alimentazione gasolio in gomma...

 Open the catalog to page 3
FORCED AIR SPACE HEATERS-4

FIRE - INFRARED SPACE HEATERS ACCESSORI A RICHIESTA / ACCESSORIES ON DEMAND TERMOSTATO AGRICOLTURA/CANTIERE -5/+50°C CON CAVO L=10 m E SPINA 90° HEAVY DUTY THERMOSTAT -5/+50°C CABLE 10 m, PLUG 90° TERMOSTATO AMBIENTE +5/+30°C CON CAVO L=10 m E SPINA 90° ROOM THERMOSTAT +5/+30°C CABLE 10 m, PLUG 90° INDICATORE DI LIVELLO FUEL LEVEL GAUGE FILTRO GASOLIO RISCALDANTE PRE-HEATED FUEL FILTER PESI E DIMENSIONI MACCHINA WEIGHTS AND DIMENSIONS MACHINE IMBALLO PACKAGING codice - code potenza term. nominale 2° stadio - rated heat power 2nd stage rendimento - heat efficiency consumo - fuel consumption potenza...

 Open the catalog to page 4
FORCED AIR SPACE HEATERS-5

FIRE - ENERATORI MOBILI A RAGGI INFRAROSSI G INFRARED SPACE HEATERS Innovazione Biemmedue soggetta a brevetto L’innovazione del generatore BM2 è l’adozione di un bruciatore dedicato BM2, in sostituzione di quelli tradizionali che si trovano in commercio (Ecoflam, Riello, Lamborghini, ecc..). Questo consente di eliminare il cono refrattario in fibra di ceramica presente nelle camere di combustione di macchine analoghe e di sostituirlo con un cono multistrato composto da 3 coni concentrici il cui raffreddamento è assicurato da un ventilatore che provvede, nel contempo, a generare il flusso d’aria...

 Open the catalog to page 5
FORCED AIR SPACE HEATERS-6

GENERATORI MOBILI D’ARIA CALDA A COMBUSTIONE DIRETTA DIRECT COMBUSTION MOBILE SPACE HEATERS www.FAIP.IT [email protected]

 Open the catalog to page 6
FORCED AIR SPACE HEATERS-7

GE - GENERATORI MOBILI D’ARIA CALDA A COMBUSTIONE DIRETTA utomatic built-in oil burner A lectronic flame-control E afety thermostat S et to be connected to a thermostat S or a humidostat or a timer (GE 36, GE 46, GE 65, GE 105) ower cord (1,5 m) with plug P ISI 430 stainless steel combustion chamber A utomatic post ventilation of unit A uel feed lines in hydrocarbon resistant rubber, F whit a reinforced textile (GE 20, GE 36, GE 46) or metal sheath (GE 65, GE 105) ank in tough hydrocarbon resistant polythene T (GE 20, GE 36, GE 46) or steel (GE 65, GE 105) ayonet-type fuel tank cap B uel tank...

 Open the catalog to page 7
FORCED AIR SPACE HEATERS-8

GE - DIRECT COMBUSTION MOBILE SPACE HEATERS ACCESSORI A RICHIESTA / ACCESSORIES ON DEMAND INDICATORE DI LIVELLO FUEL LEVEL GAUGE KIT RUOTE PNEUMATICHE Ø 250 mm PNEUMATIC WHEELS KIT Ø 250 mm FILTRO RIEMPIMENTO SERBATOIO GASOLIO FUEL TANK FILLER FILTER TERMOSTATO AMBIENTE +5/+30°C CON CAVO L=10 m E SPINA 90° ROOM THERMOSTAT +5/+30°C CABLE 10 m, PLUG 90° STAFFE SOLLEVAMENTO (4 PEZZI) LIFTING BRACKETS (4 PIECES) TERMOSTATO AGRICOLTURA/CANTIERE -5/+50°C CON CAVO L=10 m E SPINA 90° HEAVY DUTY THERMOSTAT -5/+50°C CABLE 10 m, PLUG 90° FILTRO GASOLIO RISCALDANTE PRE-HEATED FUEL FILTER KIT COLLEGAMENTO...

 Open the catalog to page 8
FORCED AIR SPACE HEATERS-9

GE - ENERATORI MOBILI D’ARIA CALDA A COMBUSTIONE DIRETTA G DIRECT COMBUSTION MOBILE SPACE HEATERS PESI E DIMENSIONI MACCHINA WEIGHTS AND DIMENSIONS MACHINE MOD IMBALLO PACKAGING potenza term. nominale - rated heat power codice - code rendimento - heat efficiency temperatura aria - air temperature consumo - fuel consumption portata d'aria - air flow capacità serbatoio - tank capacity potenza elettrica - power consumption 230 V alimentazione elettrica - electrical power quantità per pallet - pallet quantities Quadro elettrico / Electrical control board 2 1 ulsante di reset con spia di blocco (rosso),...

 Open the catalog to page 9
FORCED AIR SPACE HEATERS-10

GENERATORI MOBILI D’ARIA CALDA A COMBUSTIONE INDIRETTA INDIRECT COMBUSTION MOBILE SPACE HEATERS www.FAIP.IT [email protected]

 Open the catalog to page 10
FORCED AIR SPACE HEATERS-11

EC - GENERATORI MOBILI D’ARIA CALDA A COMBUSTIONE INDIRETTA utomatic built-in oil burner A et to be connected to a thermostat or a S humidostat or a timer ower cord (1,5 m) with plug P ISI 430 stainless steel combustion chamber; A with three smoke revolutions (EC 22, EC 32), with four smoke revolutions (EC 55, EC 85) utomatic post ventilation of unit A lectronic flame-control E afety thermostat S uel feed lines in hydrocarbon resistant rubber, F whit a reinforced textile (EC 22, EC 32) or metal sheath (EC 55, EC 85) ank in tough hydrocarbon resistant polythene (EC T 22, EC 32) or steel (EC 55,...

 Open the catalog to page 11
FORCED AIR SPACE HEATERS-12

EC - INDIRECT COMBUSTION MOBILE SPACE HEATERS ACCESSORI A RICHIESTA / ACCESSORIES ON DEMAND INDICATORE DI LIVELLO FUEL LEVEL GAUGE Cod. 02AC508 KIT RUOTE PNEUMATICHE Ø 250 mm PNEUMATIC WHEELS KIT Ø 250 mm Mod. EC 55 Cod. 02AC598 Mod. EC 85 Cod. 02AC599 FILTRO GASOLIO RISCALDANTE PRE-HEATED FUEL FILTER FILTRO RIEMPIMENTO SERBATOIO GASOLIO FUEL TANK FILLER FILTER Cod. 02AC556 TERMOSTATO AMBIENTE +5/+30°C CON CAVO L=10 m E SPINA 90° LIFTING ROOM THERMOSTAT +5/+30°C CABLE 10 m, PLUG 90° STAFFE SOLLEVAMENTO (4 PEZZI) LIFTING BRACKETS (4 PIECES) Mod. EC 55 - EC 85 Cod. 02AC511 TERMOSTATO AGRICOLTURA/CANTIERE...

 Open the catalog to page 12
FORCED AIR SPACE HEATERS-13

EC - ENERATORI MOBILI D’ARIA CALDA A COMBUSTIONE INDIRETTA G INDIRECT COMBUSTION MOBILE SPACE HEATERS TUBO SCARICO FUMI INOX L = 1 m STAINLESS STEEL EXHAUST PIPE L = 1 m CURVA A 90° SCARICO FUMI IN INOX STAINLESS STEEL EXHAUST ELBOW TERMINALE PER CAMINO IN INOX STAINLESS STEEL CHIMNEY POT PESI E DIMENSIONI MACCHINA WEIGHTS AND DIMENSIONS MACHINE MOD IMBALLO PACKAGING codice - code potenza term. nominale - rated heat power potenza term. resa - output heat power rendimento - heat efficiency portata d'aria - air flow salto termico - temperature rise consumo - fuel consumption capacità serbatoio...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.