Catalog excerpts

Fagus-GreCon Greten GmbH & Co. KG P.O. Box 1243 D-31042 Alfeld-Hanover Phone Fax E-Mail Inline Moisture Measurement with Microwave Technology Fire Protection Measuring Technology EN | R.02 | 2015.04 Subject to technical and country-specific modifications. © Fagus-GreCon Greten GmbH & Co. KG
Open the catalog to page 1
Your Benefit ■■ Extremely fast and precise moisture measurement ■■ No influence by colour and form of the material to be measured ■■ Independent of density ■■ Long-time stability ■■ Fast and early detection of troubles ■■ Contact (MM 6000) or non-contact (MM 6000 VS) measurement, depending on the customer’s requirements ■■ Non-contact measurement of endless materials (MM 6000 VS) ■■ Suitable for continuous and discontinuous material flows ■■ Continuous measurement of the moisture content of endless materials (MM 6000 VS) ■■ Measurement of the total of core and surface moisture ■■ Optical...
Open the catalog to page 2
Dimensions of measuring head (mm) Product temperature Ambient temperature Microwave power Measuring range Repeating accuracy Product memory max. 32 different calibration curves ATEX approval Material flow continuous & discontinuous continuous & discontinuous continuous & discontinuous Measuring sensor ceramic ring sensor ceramic ring sensor ceramic ring sensor slit sensor out of aluminium slit sensor out of aluminium slit sensor out of aluminium Temperature sensor external pyrometer external pyrometer external pyrometer
Open the catalog to page 3
Interfaces The systems provide analog outputs (4 to 20 mA) for the visualisation of moisture content and tempera ture as well as for data transfer to a PLC/software. Furthermore, they are equipped with digital outputs for alarming upon exceeding of limiting values as well as digital inputs for measurement control. Service GreCon measuring systems are equipped with GreCon online support SATELLITE. This provides safe, simple and fast remote support when there is trouble or to check the system. Each online support is logged and stored in the system’s history. Applications of the MM 6000 ■■...
Open the catalog to page 4All Fagus-GreCon catalogs and technical brochures
-
SYN TEST PTM
9 Pages
-
GreCon STENOGRAPH
11 Pages
-
GreCon SUPERSCAN SPR
6 Pages
-
GreCon UPU 6000
12 Pages
-
GreCon DMR 6000
10 Pages
Archived catalogs
-
GreCon IR 5000
7 Pages
-
GreCon MM 6000
8 Pages
-
GreCon DAX 6000
12 Pages
-
GreCon DML 6000
8 Pages
-
GreCon GS 6000
8 Pages
-
GRECON GA 6000
6 Pages
-
GreCon FIBERVIEW
10 Pages
-
GreCon EASYLOG+
6 Pages
-
GreCon CS 5000
10 Pages
-
CHIPINSPECTOR - FAGUS GRECON
6 Pages
-
GreCon BWS 5000
10 Pages
-
Fire protection
9 Pages
-
Measuring systems
5 Pages
-
SPM/SPL
6 Pages
-
Pipe Fire Extinguishing
2 Pages
-
BS7_Filter Monitoring
2 Pages
-
Service
4 Pages
-
Academy
2 Pages
-
BS 7 Press Protection
2 Pages
-
BS 7 Planer Protection
2 Pages