1. Catalogs
  2. Fagus-GreCon
  3. GA 6000_Dual Chamber Gas Analysis for Formaldehyde Analysis

GA 6000_Dual Chamber Gas Analysis for Formaldehyde Analysis

GA 6000_Dual Chamber Gas Analysis for Formaldehyde Analysis

GA 6000_Dual Chamber Gas Analysis for Formaldehyde Analysis

Product catalog summary
Overview: The document provides detailed information about the GA 6000, a dual chamber gas analysis system designed for formaldehyde emission analysis in wood-based panels. It highlights the system's benefits, technical specifications, and operational procedures.
Key Benefits:
  • Rapid formaldehyde emission analysis within a few hours.
  • Compliance with EN 717-2 and ISO 12460-3 standards.
  • Simultaneous measurement of two samples.
  • Data export capability via USB.
  • Programmable heating for immediate measurement start.
  • Quality control through LabCheck round robin tests.
System Features:
  • Precise and reliable measurements, even at low concentrations.
  • Compact design with low energy consumption.
  • Intuitive operation via a 10” color touch screen.
  • Automatic leak test and heated lines for condensation-free operation.
  • Online support available through GreCon SATELLITE.
Operational Procedure: The GA 6000 uses a dual chamber system to analyze formaldehyde emissions. Air is passed through pre-heated chambers containing wood panel samples, absorbing emitted formaldehyde. The air is then processed to determine formaldehyde concentration using the acetylacetone method.
LabCheck Online: This feature allows participation in round robin tests for quality control. Results are statistically evaluated and shared anonymously, helping identify and eliminate deviations.
Software Functions:
  • Operated via a touch screen with easy control over pre-heating, leak tests, and cleaning.
  • Displays and exports test parameters of the last 10 tests.
Technical Specifications:
  • Function: Formaldehyde emission determination.
  • Test Standards: EN 717-2 / ISO 12460-3.
  • Sample Size: 400 mm x 50 mm x panel thickness.
  • Testing Time: 4 hours plus analysis.
  • Flow Rate Accuracy: ± 2 l/h at 60 l/h.
  • Temperature Accuracy: ± 0.3 °C at 60 °C.
  • Pressure Accuracy: ± 30 Pa between 1000 Pa and 1200 Pa.
  • Power Supply: 110/230 V, 50/60 Hz.
  • Dimensions: 560 mm x 560 mm x 560 mm.
  • Weight: 67 kg.
Applications: The GA 6000 is used in the wood-based industry, plywood industry, furniture manufacturing, glue production, universities, research laboratories, and testing institutes.
See more

Catalog excerpts

GA 6000_Dual Chamber Gas Analysis for Formaldehyde Analysis-1

Fagus-GreCon Greten GmbH & Co. KG P.O. Box 1243 D-31042 Alfeld-Hanover Phone Fax E-Mail Dual Chamber Gas Analysis for Formaldehyde Analysis Fire Protection Measuring Technology EN | R.01 | 2015.04 Subject to technical and country-specific modifications. © Fagus-GreCon Greten GmbH & Co. KG

 Open the catalog to page 1
GA 6000_Dual Chamber Gas Analysis for Formaldehyde Analysis-2

Your Benefit ■■ Formaldehyde emission analysis in only a few hours ■■ Approved analysis according to EN 717-2 or ISO 12460-3 ■■ Accepted by CARB ■■ Simultaneous measurement of two samples ■■ Data export via USB interface ■■ Immediate measuring start by programmable heating ■■ Quality control by participation in LabCheck round robin tests ■■ Precise and reliable measured values, even with low concentrations ■■ Compact construction and low energy consumption ■■ Intuitive and safe operation via 10” colour touch screen ■■ Regulation of temperature and air flow ■■ Output of test parameters according...

 Open the catalog to page 2
GA 6000_Dual Chamber Gas Analysis for Formaldehyde Analysis-3

LabCheck Online For quality control of your tests on a regular basis, you can participate in three round robin tests per year. With LabCheck online, matched samples are tested by the participating laboratories as well as the reference laboratory (Steve Young Associates SYA) according to EN 717-2 or ISO 12460-3. The reference laboratory statistically evaluates the results and presents them - anonymised - in a report that is handed to the participants. The transmission of the measured results by the participants is done online with the access being secured by a personal password, as is the viewing...

 Open the catalog to page 3
GA 6000_Dual Chamber Gas Analysis for Formaldehyde Analysis-4

References ■■ Wood based industry ■■ Plywood industry ■■ Furniture manufacturers ■■ Glue producers ■■ Universities ■■ Research laboratories ■■ Testing institutes Detailed view of a measuring chamber

 Open the catalog to page 4

All Fagus-GreCon catalogs and technical brochures

  1. SYN TEST PTM

    9  Pages

  2. GreCon UPU 6000

    12  Pages

  3. GreCon DMR 6000

    10  Pages

Archived catalogs

  1. GreCon DAX 6000

    12  Pages

  2. GreCon CS 5000

    10  Pages

  3. GreCon BWS 5000

    10  Pages

  4. Academy

    2  Pages

  5. Service

    4  Pages

  6. SPM/SPL

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.