video corpo

VISY-Stick and VISY-Command
24Pages

{{requestButtons}}

Catalog excerpts

VISY-Stick and VISY-Command - 6

If you do not observe these safety instructions, risk of an accident exists or the VISY-X system could be damaged. Useful information that will guarantee proper function ofthe system or make your work easier. 3 4271 81096 5 10 > Fig. 1: Mode of operation of the measurement sensor 6 VISY-Stick and VISY-Command size="-3">

Open the catalog to page 6
VISY-Stick and VISY-Command - 7

For the installation and maintenance of the measurement sensor, the regulations in accordance with ElexV specifications and the German equipment safety law as well as the generally recognised rules and regulations of technology and these operating instructions are applicable.Also observe the local safety regulations and accidentprevention regulations not mentioned in this manual of operating instructions. > VISY-Stick and VISY-Command 7 >

Open the catalog to page 7
VISY-Stick and VISY-Command - 8

The measurement sensors are only allowed to be connected tomeasuring transducers that have been certified by a recognised European testing authority and the electrical data of which meet the following requirements:U > i 15VI > i 30mAP > i 0,1WYou can also connect several measurement sensors to themeasurement evaluation system.First of all, however, install the measurement sensors in thetanks by positioning the sensors centrally in the middle of tank to the extent possible. Height differences between the deepest point of the tank bottom and the end of the probe tube (= installation offset)...

Open the catalog to page 8
VISY-Stick and VISY-Command - 9

tank diameter a: deviation from the longitudinal axis [mm] > b: height difference tank bottom bottom end probe tube [mm] Fig. 2: measurement sensor > VISY-Stick and VISY-Command

Open the catalog to page 9
VISY-Stick and VISY-Command - 10

Tank muff 1 1/2 inches > During the assembly work, it is important make sure thatthe probe tube is not bent. If the tank muff intended to be used for the assembly work has an internal thread of at least 1 1/2 inches, the installation of the probe (see Fig. 3) must be carried out in the following steps. For internal threads that are larger than 1 1/2 inches, the corresponding reducer pieces must be used:Check firm fit of the retaining ring so that the floats cannotfall into the tank. > The floats must be pushed onto the probe tube with the marking facing upward so that the measurement can be...

Open the catalog to page 10
VISY-Stick and VISY-Command - 11

probe length measuring range product measuring range water >

Open the catalog to page 11
VISY-Stick and VISY-Command - 12

Tank muff = 1 inches > During the assembly work, it is important make sure thatthe probe tube is not bent. If only a 1-inch tank muff is available for the installation work, you must use a corresponding reducer piece with 1-inch external thread and 1 1/2-inch internal thread. In this case, since the float does not fit through the opening, you must proceed as follows:Loosen the dome cover, and lift it up so that the 1-inch threadhole is accessible from underneath and then use suitable materials to support the dome cover properly in this position.ՕDismantle the retaining ring and then remove...

Open the catalog to page 12
VISY-Stick and VISY-Command - 13

VISY-Stick replacement instructions In order to avoid redefining the fixed offset when fitting a newprobe you must reproduce the distance between the old probe and the floor of the tank as accurately as possible. The distance must be at least 5 mm before and after. To do this, before commencing dismantling work on the old probe mark the point where the probe tube emerges from the threaded joint using a suitable pen, as well as the position of the stuffing box on the screw body.Then undo the threaded joint (first undo the locking screw withan Allen key and then the stuffing box) and...

Open the catalog to page 13
VISY-Stick and VISY-Command - 14

Electrical connection For the wiring of each measurement sensor with themeasurement evaluation system, you will require a four-core unshielded cable which is connected in the probe head of the measurement sensor (see Fig.4). > + A B -Ger.-Nr. Fig. 4: cable connection measurement sensor The connections to be joined on the measurement evaluationsystem and on the measurement sensor identically labelled. > Observe the general installation regulations! Refer to the following table for information on the required line cross-sections. Cable lengthLine cross-section up to 200m4 x 1mm > 2 up to...

Open the catalog to page 14
VISY-Stick and VISY-Command - 15

You will require a face wrench with a diameter of 4 mm tounscrew and tighten down the probe cover. > Protect the probe head against penetrating water! Efficient sealing of the cable entry fitting is guaranteed starting from a cable external diameter of 6 mm. Make sure that the cable entry fitting is firmly screwed together and then close the probe head tightly. Calculation of installation offset At the end of the assembly work, the probe tube is pressedlightly onto the tank bottom and then pulled up 5...10 mm. This position must be maintained by tightening down the stuffing box and the...

Open the catalog to page 15
VISY-Stick and VISY-Command - 16

Explosion protection:EEx ia IIC T6Permit:T֜V 99 ATEX 1391 orTV 99 ATEX 1496System of protection:IP 68Permissibleambient temperature:-25 C to 75 C in T4(probe head)-25 C to 65 C in T5-25 C to 50 C in T6Connection data:U > I 15 VP > I 0.1 WI > i 30 mAC > i < 10 nFL > i < 0.1 mHSpecial lengths:2,000 mm (for tank diameter 1,600 mm)2,400 mm (for tank diameter 2,000 mm) 2,900 mm (for tank diameter 2,500 mm) 3,300 mm (for tank diameter 2,900 mm)Probe head:ܘ 52 mm x 107 mmProduct float:cylinder 43 mm, height 40 mm Water float:ball ؘ 43 mm orcylinder 43 mm, height 20 mmConnection:screw-in body with...

Open the catalog to page 16
VISY-Stick and VISY-Command - 17

Service mode/S1 Serial RS232 interface for system configuration using the pro- gram VISY-Setup. For this operation, the switch S1 must be in the position OFF OFF. All other switch positions are intended to be used for future options, e.g. the software VISY-Quick. > Components of interface card VI-3 (see Fig. 5 and 6) > Status display Following a system switching-on operation or a reset of the interface card VI-3, the software version is indicated first. The software version is represented by three numbers displayed after one another on the screen, e.g. 2-0-1 corresponds to version 2.01....

Open the catalog to page 17
VISY-Stick and VISY-Command - 18

2: TxD3: RxD5: -RxD Host-TxD ח Expansion-TxD Host - Status of sensors ON12 -S1 > 12345678LNPE 1 - 89 - 16 HostExpansion Display:- Service Reset Tank > + AB - + AB - + AB - + AB - + AB - + AB - + AB - + AB - + AB - + AB - + AB - + AB - > sensorsensorsensor sensorsensorsensorsensor sensor 8 PENL + AB - + AB - + AB - + AB - >

Open the catalog to page 18

All FAFNIR catalogs and technical brochures

  1. TORRIX XTS

    2 Pages

  2. TORRIX 6

    1 Pages

  3. LPG Sensors

    8 Pages

  4. SEPARIX

    8 Pages

  5. O²-PID

    4 Pages

  6. COMS Leaflet

    4 Pages

  7. QE 200

    4 Pages

  8. UM 2.1/2.2/2.3

    20 Pages

  9. TORRIX HART

    28 Pages

  10. TORRIX M12

    40 Pages

  11. LS 300 / 500

    7 Pages

  12. 76 / NB 220

    2 Pages

  13. SECON-X

    4 Pages

  14. PRESSURIX

    12 Pages

  15. Insite360

    4 Pages

  16. Plugs

    12 Pages

  17. TORRIX-HART

    28 Pages

  18. DIVELIX

    8 Pages

  19. CONDURIX-HART

    28 Pages

  20. CONDURIX

    24 Pages

  21. VAPORIX

    12 Pages

  22. VISY-X

    24 Pages

  23. Accessories

    3 Pages

  24. VISY-Reed

    4 Pages

  25. VISY-RF

    2 Pages

  26. VISY-Stick

    15 Pages

  27. TORRIX

    10 Pages

  28. TORRIX CI

    1 Pages

  29. TORRIX RS485

    3 Pages

  30. TEMPERIX

    8 Pages

  31. HPH Ex d

    3 Pages

  32. VISY-Monitor

    2 Pages

  33. VISY-Command

    5 Pages

  34. LPG-Sensoren

    8 Pages

Archived catalogs

  1. VISY-X LON

    10 Pages

  2. SEPARIX

    23 Pages

  3. VISY-View

    24 Pages