VISY-Reed Interstitial Dry The leak detection sensor for double-walled tanks with reed switch VISY-Reed Interstitial sensors detect liquids in the intermediate chamber of double-walled tanks. The level of the liquid is monitored and an alarm will be released when the threshold has been passed. Edition 05.2016 Technical changes reserved Function description VISY-Reed Interstitial sensors combine simple float switches based on reed contacts with the VISY-Sensor interface for connection to the VISY-Command. The float follows the level of the liquid as it rises, and a magnet opens a reed switch inside the sensor tube. This alarm message is transmitted directly to VISY-Command. Thanks to the low power input, VISY-Reed s ensors of different types can be operated parallel to a VISY-Stick. Features of the FAFNIR technology Solid design Housing made of brass nickel-plated, float made of stainless steel No additional cable required due to operation on the VISYSensor bus parallel to VISYStick and VISY-Reed Sump
Open the catalog to page 1Technical data VISY-Reed Interstitial Dry »» Product: Response threshold fuel: approx. 35 mm; Response threshold water: approx. 30 mm »» Float: Stainless steel Ø 26 mm »» Electrical connection: 4-wire cable »» Casing protection: IP68 »» Sensor material: Stainless steel , brass nickel-plated »» Approvals: ATEX, IECEx, NEPSI, UL-Brazil Label: White Assignment brown white black blue Cable connection brass nickel-plated Ø 46 Sensor pipe stainless steel Float stainless steel 22 | VISY-Reed Interstitial Dry – Technical Data Edition 05.2016 Technical changes reserved
Open the catalog to page 2VISY-Reed Sump The sensors for manhole and dispenser sumps with reed switches VISY-Reed Sump sensors detect liquids in the manhole sump and under the fuel dispensers. The level of the liquid is monitored and an alarm will be released when the threshold has been passed. VISY-Reed sensors are a low-cost solution for easy and reliable d etection of liquids. Edition 05.2016 Technical changes reserved VISY-Reed Sump blue for the manhole sump red for the dispenser sump Function description VISY-Reed Interstitial sensors combine simple float switches based on reed contacts with the VISY-Sensor...
Open the catalog to page 3Technical data VISY-Reed Sump »» Product: Response threshold fuel approx. 35 mm; Response threshold water approx. 30 mm; Float stainless steel Ø 26 mm »» Electrical connection: 4-wire cable »» Casing protection: IP68 »» Sensor material: Stainless steel , brass nickel-plated »» Approvals: ATEX, IECEx, NEPSI, UL-Brazil VISY-Reed Sump Label: Blue for VISY-Reed Sump Manhole Red for VISY-Reed Sump Dispenser Assignment brown + white A black B blue – Cable connection brass nickel-plated Sensor pipe stainless steel Float stainless steel 24 | VISY-Reed Sump – Technical Data Edition 05.2016 Technical...
Open the catalog to page 4All FAFNIR catalogs and technical brochures
-
TORRIX M12 MOBILE
2 Pages
-
TORRIX XTS
2 Pages
-
TORRIX 6
1 Pages
-
LPG Sensors
8 Pages
-
SEPARIX
8 Pages
-
Process Automation
28 Pages
-
O²-PID
4 Pages
-
COMS Leaflet
4 Pages
-
VAPORIX Flow and Control
40 Pages
-
Wallmounting Typ 907
4 Pages
-
QE 200
4 Pages
-
UM 2.1/2.2/2.3
20 Pages
-
TORRIX HART
28 Pages
-
TORRIX RS485 Modbus
16 Pages
-
TORRIX M12
40 Pages
-
FAFNIR Hart Setup
9 Pages
-
LS 300 / 500
7 Pages
-
76 A / NB 220
5 Pages
-
76 / NB 220
2 Pages
-
SECON-X
4 Pages
-
PRESSURIX
12 Pages
-
Insite360
4 Pages
-
Plugs
12 Pages
-
UM 2.1/UM 2.2/UM 2.3
20 Pages
-
TORRIX-HART
28 Pages
-
DIVELIX
8 Pages
-
CONDURIX-HART
28 Pages
-
CONDURIX
24 Pages
-
VAPORIX
12 Pages
-
VISY-X
24 Pages
-
Accessories
3 Pages
-
VISY-Command Web
4 Pages
-
VISY-RF
2 Pages
-
VISY-Stick
15 Pages
-
VISY-TD Display
2 Pages
-
VISY-View Touch
2 Pages
-
VPI - VISY-Power Interface
1 Pages
-
TORRIX
10 Pages
-
TORRIX CI
1 Pages
-
TORRIX RS485
3 Pages
-
UM-X Transducer
3 Pages
-
TEMPERIX
8 Pages
-
HPH Ex d
3 Pages
-
VISY-Monitor
2 Pages
-
VISY-Input VISY-Output
4 Pages
-
VISY-Command
5 Pages
-
LPG-Sensoren
8 Pages
Archived catalogs
-
2019 VISY-Stick Flex
2 Pages
-
2016 VISY-Stick Flex
2 Pages
-
VISY-X LON
10 Pages
-
SEPARIX
23 Pages
-
VAPORIX Flow/Control
32 Pages
-
VISY-Setup V 3.1.0
40 Pages
-
VISY-Setup V2.10
42 Pages
-
VISY-View
24 Pages
-
VISY-Stick and VISY-Command
24 Pages
-
Overfill Prevention (GWG)
12 Pages