video corpo

O²-PID
4Pages

{{requestButtons}}

Catalog excerpts

O²-PID - 1

Overfill Prevention and Product Identification for fuel drop at petrol stations Sensors & Systems Worldwide: www.fafnir.com

Open the catalog to page 1
O²-PID - 2

O1-PID Overfill Prevention & Product Identification Benefits of the overfill and cross over prevention system with O1-PID Application The O1-PID System is a safety device to prevent the overfilling of storage and bunker tanks when filled with petrol, diesel or fuel oil. The system consists of an optical liquid detector with product identification (O2-PID) ■ Much easier handling of the fuel drop ■ No extra cable at the road tanker is needed for the overfill prevention ■ The connection to the O1-PID detector is realized by electrically conductive hoses in the storage tank and an evaluation...

Open the catalog to page 2
O²-PID - 3

The connection couplings of the hoses are electrically isolated. Therefore it is possible to supply the O2-PID fluid detector with an intrinsic safe current and to read its measured values. The status of the detector is interrogated 10 times per second. If a liquid touches the optical prism of the O2-PID detector, the status of the detector changes and a corresponding signal is transmitted to the road tanker electronics (PRD). Every evaluation in accordance with EN 14116 can read the PID and overfill information! The System There are three important tasks that are served by the new O2-PID ■...

Open the catalog to page 3
O²-PID - 4

Probe length FAFNIR Technical Data of O2-PID Operating data » Temperature range: -40 °C to +60 °C » Pressure range: 0,1 MPa Optical detection principle » Prism: Polysulfon Materials » Wetted parts: Stainless steel 1.4301 (304); Brass; Viton; Polysulfon Dimensions » Diameter of sensor tube: 16 mm » Length: 600 mm » Screw-in unit G 1 » Cable connection: 2 m of two wire lead Approvals » Overfill prevention device EN 13616 » Communication of PID: EN 14116 » ATEX: II 1 G Ex ia IIB T4 Ga Threshold point FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg, Germany Phone: +49/40/39 82 07-0 E-Mail:...

Open the catalog to page 4

All FAFNIR catalogs and technical brochures

  1. TORRIX XTS

    2 Pages

  2. TORRIX 6

    1 Pages

  3. LPG Sensors

    8 Pages

  4. SEPARIX

    8 Pages

  5. COMS Leaflet

    4 Pages

  6. QE 200

    4 Pages

  7. UM 2.1/2.2/2.3

    20 Pages

  8. TORRIX HART

    28 Pages

  9. TORRIX M12

    40 Pages

  10. LS 300 / 500

    7 Pages

  11. 76 / NB 220

    2 Pages

  12. SECON-X

    4 Pages

  13. PRESSURIX

    12 Pages

  14. Insite360

    4 Pages

  15. Plugs

    12 Pages

  16. TORRIX-HART

    28 Pages

  17. DIVELIX

    8 Pages

  18. CONDURIX-HART

    28 Pages

  19. CONDURIX

    24 Pages

  20. VAPORIX

    12 Pages

  21. VISY-X

    24 Pages

  22. Accessories

    3 Pages

  23. VISY-Reed

    4 Pages

  24. VISY-RF

    2 Pages

  25. VISY-Stick

    15 Pages

  26. TORRIX

    10 Pages

  27. TORRIX CI

    1 Pages

  28. TORRIX RS485

    3 Pages

  29. TEMPERIX

    8 Pages

  30. HPH Ex d

    3 Pages

  31. VISY-Monitor

    2 Pages

  32. VISY-Command

    5 Pages

  33. LPG-Sensoren

    8 Pages

Archived catalogs

  1. VISY-X LON

    10 Pages

  2. SEPARIX

    23 Pages

  3. VISY-View

    24 Pages