LEAK PREVENTION TECHNOLOGY For a clean and protected environment FAFNIR Sensors & Systems VIMS Vacuum Interstice Monitoring System VIMS is the smart solution for leak detection and leak prevention for double walled pipes and tanks. A leak in either of the walls will be detected before any product can enter the environment. VIMS fulfils the highest level of environmental protection and meets the requirements for class I leak detection EN 13160-2. The VIMS sensor is directly connected to the FAFNIR VISY-X technology, displaying detailed information: ■ Actual status of the system pressure and vacuum pump ■ Leak alarms for air, water and product ■ Identification of the monitored tank, pipe or pipe section. Intelligent monitoring allows appropriate reactions on leak alarms reducing profit losses Any alarm requires reaction! False alarms need to be avoided. An alarm should be identified immediately revealing the reason and components involved. A pump shut down due to a leak alarm always causes profit losses and should be avoided as long as possible. Depending on the type of alarm the VIMS technology is able to decide if an immediate shutdown of the submersible turbine pump (STP) is needed or not. VIMS provides the perfect solution: ■ No false alarms ■ The FAFNIR VISY-Command GUI displays alarms and differentiates by type and component: • Air leak: the secondary wall is no longer tight, but the vacuum in the interstice is still maintained. There is no immediate risk for environmental pollution, which allows a certain reaction time for trouble shooting. • Water leak: Ground water enters through the secondary. No immediate environmental risk. Allowance for sufficient reaction time for maintenance. • Product leak on a tank: STP will continue running to empty the tank. Tank refilling should be prevented. • Product leak on a pipe: Primary pipe is leaking. The STP will create overpressure in the interstice and product might pollute the environment. In case of product in the interstice, the STP will be shut down immediately. The differentiation of air-, groundwater- or product leaks will reduce profit losses caused by unnecessary fuel pump shut offs. Germany [email protected] FAFNIR GmbH Tel.: +49/40/39 82 07-0 Germany [email protected]
Open the catalog to page 1LEAK PREVENTION TECHNOLOGY FAFNIR For a clean and protected environment Sensors & Systems VIMS Vacuum Interstice Monitoring System Operating Conditions: Temperature range: -20/+60°C Power supply: 24 V DC Germany [email protected] FAFNIR GmbH Tel.: +49/40/39 82 07-0 Germany [email protected]
Open the catalog to page 22 Pages
2 Pages
1 Page
8 Pages
8 Pages
28 Pages
4 Pages
4 Pages
40 Pages
4 Pages
4 Pages
2 Pages
20 Pages
28 Pages
16 Pages
40 Pages
9 Pages
7 Pages
5 Pages
4 Pages
12 Pages
4 Pages
12 Pages
20 Pages
28 Pages
8 Pages
28 Pages
24 Pages
12 Pages
24 Pages
3 Pages
4 Pages
4 Pages
2 Pages
15 Pages
2 Pages
2 Pages
10 Pages
1 Page
3 Pages
3 Pages
8 Pages
4 Pages
5 Pages
8 Pages
3 Pages
2 Pages
2 Pages
2 Pages
10 Pages
23 Pages
32 Pages
40 Pages
42 Pages
24 Pages
24 Pages
12 Pages