Open the catalog to page 1Process Automation Edition 05.16 Right to technical changes reserved TORRIX The Accurate Solution for your Application: Magnetostrictive Level Sensor The most adaptable level sensor in our range, TORRIX can be used across a multitude of the most complicated level measurements applications. Users benefit from quick and easy installation, proven reliability and simple troubleshooting. With its highly precise magnetostrictive measuring principle, TORRIX achieves outstanding accuracy of up to ±0.3 mm, among the very best in its class. Why Choose TORRIX? Quick and Precise Main Features and Benefits...
Open the catalog to page 2Process Automation Edition 05.16 Right to technical changes reserved TORRIX – Technical Data Probe head Protection class M16 x 1.5 cable gland for cable diameter 5 to 10 mm; ½” NPT thread for conduit cabling; M12 connector Ambient temperature Probe tube Material Stainless steel 1.4571 (316Ti); Hastelloy® C4/C22; Titan Resolution (HART®) Electrical connection Installation length Probe length Filling level Output power: 4 to 20 mA/HART®; Failure mode per NAMUR NE43 HART® functions Float position in mm, cm, m, inches or feet; positioning of second float; separation layer (difference between floats);...
Open the catalog to page 3Process Automation Edition 05.16 Right to technical changes reserved TORRIX RS485 – Technical Data Ø 47.2 Probe head Casing protection class Equipotential bonding Probe head Stainless steel Cable terminal Ambient temperature Probe tube Material Accuracy Filling level Probe length Electrical connection Connection Product float Interface float Guard ring Modbus (ASCII); FAFNIR Universal Device Protocol* Probe tube Ø 12 Stainless steel Positioning of up to two floats; Temperature (optional); Sensor status information; configuration Process conditions Temperature Up to 450 °C For probes with integrated...
Open the catalog to page 4Technical Data Process Automation Edition 05.16 Right to technical changes reserved TORRIX SC – Technical Data Ø 47.2 Probe head Protection class Equipotential bonding Probe head Stainless steel Cable terminal Ambient temperature Probe tube Material Accuracy Filling level Probe length Electrical connection Connection Voltage FAFNIR serial protocol (LOGI-X and VISY-X) Probe tube Ø 12 Stainless steel Positioning of up to two floats; Temperature (optional); Sensor status information; configuration Process conditions Product float Up to 450 °C For probes with integrated temperature sensors: -40 °C...
Open the catalog to page 5Process Automation Edition 05.16 Right to technical changes reserved Probe length Probe length TORRIX Flange O ur standard sensor, with a variable process connection. The installation length can be adjusted directly on the tank during installation. The process connection is airtight welded to the sensor. This makes it especially suitable for applications in toxic liquids or at high pressures and temperatures. The sensor head bends by 90°; which reduces the needed head space significantly. The best solution where head space is limited, i.e. for barrels stored under a table or in a safety cabinet....
Open the catalog to page 6Process Automation Edition 05.16 Right to technical changes reserved Probe length Probe length Probe length Probe length TORRIX Bypass TORRIX Flex T / F Our best solution for mounting on the outside of a magnetic level indicator. The TORRIX Bypass picks up the magnetic field of the floater. The ideal solution for retrofitting most brands of magnetic level indicator. Where space in the process container is limited, our compact version of the TORRIX is ideal for application in small containers, for example in the laboratory or in pilot plants. When not only the space in the container is limited,...
Open the catalog to page 7Process Automation Edition 05.16 Right to technical changes reserved TORRIX Installation Kit Function Clamping ring The installation kit consists of a jacketed pipe with process fitting and float. The installationPTFEis Material: kit installed in the tank and the TORRIX measuring sensor is then inserted into the jacketed pipe. TORRIX picks up the magnetic field of the float on the installation kit and can thereby determine the product filling level The sensor does not come in direct contact with the medium. ¾” NPT Probe lengh Installation length Installation length Aggressive liquids Probe tube...
Open the catalog to page 8Technical Data Process Automation Edition 05.16 Right to technical changes reserved Installation Kit Options Thread G ½" Gas-proof welded Flange on order Heavy-Duty Installation Kit Probe tube Installation length Tube Ø 18 x 2 Float on order Guard ring dismountable Process connection Welded flange or thread Process conditions Temperature TORRIX VT – Technical Data A vibration-resistant version for use in tank trucks, mobile tanks, tank wagons and other applications in which containers are subject to strong vibration. Probe head Cable terminal Ambient temperature Casing protection class Sensor...
Open the catalog to page 9FAFNIR GmbH E-mail: [email protected] Internet: www.fafnir.com Sensors & Systems Worldwide: www.fafnir.com
Open the catalog to page 102 Pages
2 Pages
1 Page
8 Pages
8 Pages
28 Pages
4 Pages
4 Pages
40 Pages
4 Pages
4 Pages
2 Pages
20 Pages
28 Pages
16 Pages
40 Pages
9 Pages
7 Pages
5 Pages
4 Pages
12 Pages
4 Pages
12 Pages
20 Pages
28 Pages
8 Pages
28 Pages
24 Pages
12 Pages
24 Pages
3 Pages
4 Pages
4 Pages
2 Pages
15 Pages
2 Pages
2 Pages
1 Page
3 Pages
3 Pages
8 Pages
4 Pages
5 Pages
8 Pages
3 Pages
2 Pages
2 Pages
2 Pages
10 Pages
23 Pages
32 Pages
40 Pages
42 Pages
24 Pages
24 Pages
12 Pages