1. Catalogs
  2. FAE Srl
  3. flow-captor 4115.30

flow-captor 4115.30

flow-captor 4115.30

Product catalog summary
Overview: The flow-captor 4115.30 is an industrial flow meter designed for non-intrusive installation in pipes, ensuring no obstruction to pipe diameter. It operates on the calorimetric principle, offering a wide measuring range and is encapsulated in epoxy resin for durability and stability in harsh conditions.
Specifications:
  • Medium: Water-based and oil-based media.
  • Adjustable Range: 0 - 20 cm/s to 0 - 200 cm/s for water; 0 - 200 cm/s for oil.
  • Temperature: Medium: -10°C to +80°C; Ambient: -10°C to +60°C.
  • Pressure: Maximum 30 bar.
  • Response Time: 2 - 10 seconds.
  • Linearity Deviation: Less than 5%.
  • Repeatability: Less than 2%.
  • Temperature Drift: Less than 0.3% per Kelvin.
Mechanical Data:
  • Protection Class: IP65.
  • Material: Stainless steel housing and sensor (AISI 303).
  • Mounting Accessories: Union nut G1A, SW 37 mm.
  • Dimensions: Ø 25/30 x 96.5 mm.
Electrical Data:
  • Operating Voltage: 24 VDC ±10%.
  • Current Consumption: Approximately 100 - 200 mA.
  • Current Output: 4 - 20 mA.
  • Load: Maximum 600Ω.
Key Features:
  • Precise flow measurement for water-based media.
  • Adjustable measuring range without moving parts.
  • Linear current output of 4 – 20 mA.
  • ISO 9001:2008 certified.
Contact Information: FAE S.R.L., Via Tertulliano, 41, 20137 Milano. Tel: +39 02 55187133, Fax: +39 02 55187399, Email: [email protected], Website: www.fae.it
See more

Catalog excerpts

flow-captor 4115.30-1

Flow meter for liquid media The flow-captor 4115.30 is a flow meter for industrial applications which can be installed virtually non-intrusively into any pipe without obstruction of the pipe diameter. This flow-captor operates accordingly to the calorimetric principle providing a wide measuring range. Completely epoxy resin encapsulated this flow-captor is a compact, rugged, shock and vibration resistant sensor with proven reliability and long-term stability, even under the most harsh environmental conditions. • precise flow meter for water based media • adjustable measuring range • without any moving parts • linear current output 4 - 20 mA • housing and sensor head stainless steel AISI 303 Technical Data Type Medium Sensor Data *1 Measuring range Set-point range Medium temperature Ambient temperature Pressure Response time Linearity deviation Repeatability Temperature drift Mechanical Data Protection class Material housing / sensor Material of sensor probe Mounting accessories Electrical connection Housing dimensions Electrical Data Operating voltage Current consumption Current output Load waterbased media oilbased media cont. adjustable from 0 - 20 cm/s to 0 - 200 cm/s1 cont. adjustable from 0 - 200 cm/s2) other range on request Zero point and range adjustment by potentiometer - 10°C to + 80°C - 10°C to + 60°C max. 30 bar 2 -10 s depends on measuring conditions < 5% best fitting slope < 2% < 0,3% / K IP65 stainless steel WN 1.4305 / AISI 303 (other material on request) FP (Viton) Union nut G1A, SW 37 mm (stainless steel WN 1.4305 / AISI 303) 2 m moulded oilflex cable 3 x 0,5 mm2 0 25/30 x 96,5 mm 24VDC ±10% approx. 100 - 200 mA (at max. flow) 4 - 20 mA max. 600Q 1 data relate to water 2) calibrated with insulation oil type "Shell Diala" Housing dimensions: Connection diagram: Technical data subject to alteration! ■ Rev. AD / 20.04.16 since 1976 www.fae.it e-mail: [email protected]

 Open the catalog to page 1

All FAE Srl catalogs and technical brochures

  1. foto-captor

    2  Pages

  2. FOI-58

    7  Pages

  3. LS50-2D

    1  Page

  4. Mikro

    4  Pages

  5. SERIE PZ

    12  Pages

  6. LPU-2428

    2  Pages

  7. PICA100-P

    2  Pages

  8. GAMMA-M

    4  Pages

  9. ALPHA-P

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.