Overview: This document provides technical specifications and installation guidelines for automated systems used in rolling shutters, specifically focusing on gearmotors R180 and R280. It includes details on transmitters, key-operated push-buttons, photocells, safety devices, flashing lamps, and various accessories.
Specifications:
  • Power Supply: 230 Vac (+6% -10%) 50/60 Hz
  • Absorbed Current: R180 - 2.4 A, R280 - 4.4 A
  • Drive Torque: R180 - 180 Nm, R280 - 280 Nm
  • Operating Temperature: -20°C to +55°C
  • Lifting Capacity: R180 - 180 kg, R280 - 280 kg
  • Maximum Shutter Height: 8 m
  • Maximum Shutter Width: 4.5 m
Installation Notes:
  • Configuration excludes safety devices, which must be determined by a specific risk analysis as per UNI-EN 12445 and 12453 standards.
  • Installation costs and expenses for masonry, electrical, and metalwork preparations are not included in the indicated price.
Typical Installation Example:
  • Low voltage cabling: 1 cable 3x0.5 mm²
  • Power cabling (230V): 1 cable 2x1.5+T mm², 1 cable 3x1.5+T mm²
Accessories and Control Units:
  • Burglar-resistant key-selector with lever release (XK21L24 V)
  • Electric brake for R180
  • Control unit with 'dead man' logic (200 BT)
Additional Notes:
  • Specific accessories for R180 and R280 include anti-drop devices and electric brakes.
  • Control units and enclosures are compatible with models 200 MPS and 200 BT.
See more

Catalog excerpts

Automated system R180-1

Automated systems for rolling shutters Key-operated push‑buttons page 185 Photocells and Columns page 189 Safety devices page 191 Flashing lamps page 193 Transmitters page 182 Various accessories page 194 83

 Open the catalog to page 1
Automated system R180-2

R 180 - R 280 Gearmotors for spring balanced rolling shutters • Facility for application of anti-drop safety device (EN 13241-1) • Limit switches with self-learning adjustment (Patented) • pplication possible, with adapters included, on shutters with shaft diameter A of 60/48/42 mm and spring boxes of 200/220 mm • Shutter max height: 8 m DIMENSIONS AND TECHNICAL SPECIFICATIONS R180 - R280 Power supply voltage Absorbed current Drive torque Operating ambient temperature Lifting capacity Winding flange speed Shutter shaft diameter Winding flange diameter Maximum shutter height Maximum shutter width...

 Open the catalog to page 2
Automated system R180-3

R 180 - R 280 - 227 L Shutter shaft diameter (mm) 60/48/42 60/48/42 60/48/42 60/48/42 76 R 180 R 180 EF (*) R 280 R 280 EF (*) 227 L Use Diameter of spring boxes (mm) 200/220 200/220 200/220 200/220 240 Control unit Use frequency (%) 25 25 25 25 20 Item code Not included Not included Not included Not included Not included Price (euro) 109910 109912 109911 109913 109704 Automated systems for rolling shutters Model The packages R180 - R280 include: a gearmotor, winding flange adapters 200/220, shaft reduction tube 60-48-42. installation accessories. CONTROL UNITS Control unit with “dead man” logic...

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.