The eyc-tech PHM330 is a differential pressure transmitter designed for precise airflow measurement. It features a hot-wire type differential pressure sensor, which offers high sensitivity at low differential pressures and minimal zero-point drift. The device is housed in an aluminum alloy casing with an IP65 protection rating, ensuring durability and resistance to environmental factors.

Specifications
- Measuring Range: ±50 to ±1500 Pa
- Output: 4-20 mA, 0-10 V, RS-485
- Accuracy: ±1.5% F.S. ±3% M.V.
- Operating Temperature: -20 to +80°C (Non-display), 0 to +50°C (Display)
- Protection: IP65, over-voltage, reverse polarity, short circuit
- Pressure Resistance: 1 bar, Burst Pressure: 3 bar
- Certification: CE

Hot-wire Type Differential Pressure Principle
This technology measures pressure differences by calculating airflow rates. It uses a heating element and temperature sensors to detect changes in air flow, allowing for precise measurement of small pressure differences. The technology is known for low zero-point drift, ensuring long-term measurement stability.

Applications
The PHM330 is suitable for exhaust air treatment, differential pressure monitoring, airflow monitoring, water treatment, and air handling unit flow.

Connection and Installation
The device supports both DC 24 V and AC 24 V power supplies and features an M12 connector with a 2m cable. It is designed for wall installation and includes a DIP switch for range adjustment and square root function.

Ordering Guide
Options include different pressure ranges (e.g., 0-500 Pa, 0-1000 Pa), output types (4-20 mA + RS-485, 0-10 V + RS-485), and display options (LCD or non-display).
See more

Catalog excerpts

eyc-tech PHM330 Differential Pressure Transmitter-1

Differential Pressure Transmitter Uses hot-wire type differential pressure sensor High sensitivity at low differential pressure, low zero-point drift, minimum measurable value as low as 1 Pa Pressure resistance up to 1 bar, differential pressure measurement range of ±50 ... ±1500 Pa Aluminum alloy housing, IP65 protection rating Includes square root function for converting into air velocity and airflow, and simultaneous display on the screen Provides analog output with RS-485 communication function DIP switch to adjust range and square root function The eyc-tech PHM330 differential pressure transmitter, equipped with an aluminum alloy housing, is less affected by the external environment, ensuring stable and reliable airflow measurement. Its sensing element is a hot-wire type sensor, providing excellent zero-point stability and the ability to detect low differential pressures, allowing for precise measurements at low air velocities. Exhaust air treatment / Differential pressure monitoring / Airflow monitoring / Water treatment / A

 Open the catalog to page 1
eyc-tech PHM330 Differential Pressure Transmitter-2

Measuring element Measuring range Hot-wire type diff. pressure sensor, flow-through Load resistance Signal connection Response time Display type Display range Digit height Accuracy Accuracy Temperature influence Measuring medium Operating temperature Operating humidity Storage temperature LCD Module with back light, M12 connector *with 2 m cable Wall type Electrical protection Electrical connection Q=Air quantity (with eyc-tech AFMT) Overvoltage protection Current consumption double line character Power supply ■ Reverse polarity ■ Short circuit 1 bar Pressure resistance Burst pressure Aluminum...

 Open the catalog to page 2
eyc-tech PHM330 Differential Pressure Transmitter-3

| with the eyc-tech Pitot Tube Principle | eyc-tech PHM330 Differential Pressure Transmitter is built on the structure of thermal mass flow measurement, with eyc-tech AFMT Average Flow Measuring Tube(Pitot tube), based on the flow continuity formula (the law of conservation of mass) and the Bernoulli formula (the law of conservation of energy), the wind speed calculation formula is deduced to achieve an effective and accurate measurement. Flow rate formula V = K Flow formula Δ P = Difference between total pressure and static pressure ρ (Dynamic pressure)(Pa) = Flow density(kg/m3) = Flow coefficient...

 Open the catalog to page 3
eyc-tech PHM330 Differential Pressure Transmitter-4

P1 25 mm M12x1 Screw thread (Connector) 104 mm 134 mm ※P1 / P2 : Connected to Ø6 PVC / PTFE compressed air pipe Brown Black Gray White Blue *Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product. | Ordering Guide | Installation Electrical connection M : M12x1 connector *with 2m cable | Additional Option Test Report | For more detailed information please contact us. ■ ISO 9001 Project Measurand level or range