1. Catalogs
  2. eyc-tech
  3. eyc-tech FDM06-I Venturi Thermal Mass Flow Meter

eyc-tech FDM06-I Venturi Thermal Mass Flow Meter

eyc-tech FDM06-I Venturi Thermal Mass Flow Meter

eyc-tech FDM06-I Venturi Thermal Mass Flow Meter

Product catalog summary
Applications
The document outlines the applications of the Venturi Thermal Mass Flow Meter, FDM06-I, which include compressed air systems, pneumatic systems, dryers, air consumption monitoring, and pipeline leak monitoring.
Features
The FDM06-I features precise measurement using a unique Venturi tube structure, a 2-inch LCD screen for easy configuration, and display features that show both instant and cumulative measurements. The screen can rotate 90 degrees for better viewing. It supports multiple pipe diameters (DN15, DN25, DN40, DN50) for easy installation and offers an accuracy of ±1.5% F.S. with a pipeline withstand pressure of 16 bar. The device provides multiple outputs including analog, relay, and RS-485.
Specifications
The flow meter uses a hot-wire sensor with a turndown ratio of 100:1. It has a measuring range of up to 500 Nm³/h depending on the pipe size. Output signals include 4-20 mA, 0-10 V, relay, and RS-485, with a warm-up time of 60 seconds and a response time of t90≦6 seconds. It operates with non-corrosive gases at temperatures between 0-50°C and humidity levels of 20-90% RH. The device is powered by DC 24 V with a current consumption of 110 mA and a relay capacity of 6 A.
Measurement Principle
The FDM06-I employs a Venturi tube based on the Venturi effect, which measures flow rate by calculating the differential pressure at two points. This method allows for high accuracy and low pressure loss, suitable for various fluids including gases, liquids, and steam. The robust structure requires minimal maintenance.
Calibration System
The calibration system is based on ISO 9300 standards for flow measurement using critical flow Venturi nozzles. It covers air volume ranges from 0.5 m³/h to 1000 m³/h.
Ordering Guide
The document provides an ordering guide with options for diameter and range, connection type, output, and additional options. It also mentions the availability of test reports from YUDEN-TECH CO., LTD. Calibration Laboratory, accredited by ILAC/TAF.
See more

Catalog excerpts

eyc-tech FDM06-I Venturi Thermal Mass Flow Meter-1

www.eyc-tech.com Features • Precise Measurement : Utilizes a unique Venturi tube structure • 2" LCD Screen : Easily configurable with buttons • Display Features : Shows instant and cumulative measurements; screen rotates 90 degrees for easy viewing • Multiple Pipe Diameters Available : (DN15 / DN25 / DN40 / DN50) for easy installation • Accuracy : ±1.5% F.S., pipeline withstand pressure of 16 bar • Multiple Outputs: Analog output / Relay / RS-485

 Open the catalog to page 1
eyc-tech FDM06-I Venturi Thermal Mass Flow Meter-2

SpecificationInput Sensor type Hot-wire sensor *The measurement range is defined at the standard condition(1013 mbar, 20°C). Current consumption 24 V : 110 mA Relay capacity Max current : 6 A Max voltage : DC 24 V (DC 36 V Max) Electrical connection M12 8P connector Output signal 4 ... 20 mA / 0 ... 10 V / Relay / RS-485 Load resistance Current output : ^500 Q Communication methods & protocol RS-485 Modbus RTU RS-485 baud rate 9600'19200'38400'57600'115200 bps Pipe connection G thread Display readout 0 ... 99999999 (Cumulative flow : 8-digit) 0 ... 99999 (Instantaneous flow : 5-digit) Decimal...

 Open the catalog to page 2
eyc-tech FDM06-I Venturi Thermal Mass Flow Meter-3

| Measurement Principle | ■ Venturi tube The Venturi tube is a flow measurement device designed based on the Venturi effect and is often used in conjunction with differential pressure transmitters. The flow rate is calculated by measuring the differential pressure at two points in the Venturi tube. When flow passes through the narrow center of the Venturi tube, its velocity increases while the pressure decreases; this phenomenon is known as the Venturi effect. According to Bernoulli's principle and the continuity equation, the pressure difference between the inlet section and the narrow center is proportional...

 Open the catalog to page 3
eyc-tech FDM06-I Venturi Thermal Mass Flow Meter-5

| Ordering Guide | Diameter & Range | Calibration System | Air volume standard calibration system Air volume : 0.5 m³/h ... 1000 m³/h Referring to ISO 9300 "Flow Measurement of Critical Flow Venturi Nozzles", this device is a standard flow device combination consisting of multiple venturi nozzles according to the maximum According to ISO 9300 Critical Flow Venturi Nozzle Flow Measurement Sonic speed V=331.6+0.6T(m/s) and minimum flow ranges that need to be calibrated. | Additional Option Test Report | For more detailed information please contact us. ■ILAC / TAF YUDEN-TECH CO.,LTD. Calibration Laboratory...

 Open the catalog to page 5

All Eyc-tech catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.