Description: The Suction System AS-1 is designed for sampling measured gas at a single measuring point, integrating the sampling and transmitter in a wall-mounted housing.
Features:
  • Transmitter: One transmitter is required but not included. It is freely selectable.
  • Control Unit: Operated externally, for example, by an ExTox Control Unit.
  • Gas Sampling: Utilizes a gas suction pump with electrical flow-through monitoring. A fault message is issued if the minimum volume stream is not met, disrupting the transmitter output signal (4…20 mA).
  • Connections: Two screw-in connections (4/6 mm) for gas inlet and outlet at the housing bottom.
  • Suction Distance: Up to 50 meters using a 4/6 mm hose.
  • Gas Conditioning: Standard hosing is PE/PP, with an optional flame arrestor.
  • Operating Temperature: -10 °C to +40 °C, with limitations based on the transmitter used.
Mechanical Features:
  • Dimensions: 300 mm x 380 mm x 155 mm (Height x Width x Depth).
  • Housing: Wall-mounted with a door, mounting plate, foamed-in door sealing, and a cam lock.
  • Material: Steel, powder-coated in RAL 7035.
  • Storage Temperature: -25 °C to +60 °C, with limitations based on the transmitter used.
Electrical Features:
  • Power Supply: 230 V AC for the pump and 24 V DC for the transmitter.
  • Cable Gland: Located at the housing bottom with sizes M20 x 1.5 and M16 x 1.5 for different cable diameters.
  • Terminal Assignment: Double stock clamps for power supply and transmitter connections.
Options:
  • ExTox Transmitter: A suitable transmitter can be selected from the ExTox program, with advice available for gas compatibility with hosing materials.
  • ExTox Control Unit: The system's measuring signal can be evaluated by any ExTox Control Unit.
  • Flame Arrestor: Options include IIG IIB3 or IIG IIC for hazardous areas, ensuring safety by decoupling the gas flow from the monitored process.
Note: Subject to technical changes.
See more

Catalog excerpts

410102_AS-1_e-1

Suction System AS-1 Article-No.: 410102 Description Features Transmitter Control Unit Sampling of Measured Gas Distance for Suction Conditioning of Measured Gas Operation Temperature Mechanical Features Dimensions Housing Material Storage Temperature Electrical Features Power Supply Cable Gland Terminal Assignment Suction System for 1 measuring point: sampling of measured gas and transmitter combined in one wall mounted housing. ■ Number: 1 (not included in scope of delivery) ■ Freely selectable Externally, e. g. by ExTox Control Unit ■ Gas suction pump ■ Electrical flow-through monitoring by means of pressure difference measurement: in case of under-scale of the minimum volume stream a fault message is issued by disrupting the transmitter output signal (4...20 mA) ■ 2 screw-in connections (4/6 mm) for inlet and outlet of measured gas at the bottom of the housing > 50 m when using hose 4/6 mm(inner/outer 0: 4/6 mm) ■ Hosing: PE/PP ■ As Option: Flame Arrestor -10 °C to +40 °C (Limitations due to used transmitters have to be considered) 300 mm x 380 mm x 155 mm (Height x Width x Depth) Wall mounted housing with door, mounting plate, foamed-in door sealing, 1 cam lock Steel, powder-coated in textured RAL 7035 -25 °C to +60 °C (Limitations due to used transmitters have to be considered) ■ 230 V AC (Pump) At the bottom of the housing ■ 1 x M20 x 1.5 (diameter of cable 7-13 mm) Double stock clamps for ■ Power Supply (230 VAC fused with 2 A) ■ Transmitter (+ 24 VDC, GND, 4.20 mA) ExTox Gasmess-Systeme GmbH • Max-Planck-StraGe 15 a • 59423 Unna (Germany) • Tel. +49 2303 33 247-0 • Fax +49 2303 33 247-10 Internet: www.extox.de • mail to: [email protected]

 Open the catalog to page 1
410102_AS-1_e-2

Suction System AS-1 Article-No.: 410102 Options ■ ExTox-Transmitter: Depending on type of measured component a suitable transmitter can be chosen out of the ExTox programme. As far as incompatibilities of some gases with hosing materials are concerned ExTox will be at your disposal in case you require any advice. ■ ExTox-Control Unit: The measuring signal supplied by the Suction System AS-1 can be evaluated by every ExTox-Control Unit. ■ Flame Arrestor <© IIG IIB3 (Art.-No. 940250) or © IIG IIC, e. g. for hydrogen (Art.-No. 940251): When sampling in hazardous areas the gas flow inside the AS-1...

 Open the catalog to page 2

All ExTox Gasmess-Systeme catalogs and technical brochures

  1. NH3-Stable

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.