Catalog excerpts
TECHNICAL FOCUS FE SYSTEM ELECTROSTATIC FILTER HIGH TECH SOLUTION FOR AIR PURIFICATION
Open the catalog to page 1SUMMARY Details Operation principle Main constructive features Filtration efficiency Abatement of microorganisms (dusts, virus, bacteria) Energy consumption of the filtering system ROI economic analysis Conclusions Frequent questions
Open the catalog to page 3DETAILS The use of static air filtration dates back to the early 1900s, when a newly patented device in the United States was employed for the abatement of fumes which came from a sulfuric acid synthesis system. OPERATION PRINCIPLE Thanks to the specialization in different applications and to the evolution of materials and control systems, this principle is now available in many constructive variants of different complexity, which are intended for specific applications such as air treatment and air conditioning (shopping centers, hospitals, offices), or in the food, textile, mechanical or...
Open the catalog to page 4MAIN CONSTRUCTIVE FEATURES The FE SYSTEM series consists of a new range of active electrostatic filters, very practical and usable in substitution or in addition to traditional mechanical filters (bag and pocket filters), in new and /or existing installations without adaptation costs. FE SYSTEM electrostatic filters are made up of a metallic aluminum body, which, during the filtration process, intercepts the pollutant by accumulating it on the capture blades. Its adoption in ventilation systems and in particular in the air conditioning industry does not require changes in the structural and...
Open the catalog to page 5MAIN CONSTRUCTIVE FEATURES 1 - ADAPTABLE One of the main features of the FE SYSTEM Filters is the applicability in a variety of industries thanks to the standard sizes compatible with the pocket filters. AIR CONDITIONING: Installation inside conditioning units for residential, tertiary and industrial sectors. INDUSTRIAL: Filtration of micro dusts, rubber and plastic fumes, fumes in general, welding fumes (such as ferrous metals, precious metals, control panels) with a maximum concentration of 20 mg/m. HOSPITAL: Control of aerodynamic contamination for hospital rooms, white rooms, outpatient...
Open the catalog to page 63 - INCORPORATED ELECTRONIC Circuit A feature that distinguishes the FE SYSTEM Filters is the built-in electronics that generates the high voltage needed for the operation of the filter. Led Multi-pole connectors can be used to connect multiple filters with one power line (230V to 50Hz) and provide the alarm signal. Integrated electrostatic circuit with complete watertightness. 4 - CERTIFICATED EFFICIENCY The FE SYSTEM filters have been tested by independent and international organizations, which have issued the following certifications: UNI 11254 : 2007 EN 1822 : 2005 EN 779 : 2012 It...
Open the catalog to page 7FILTRATION EFFICIENCY I filtri elettrostatici “bitensione” presentano un’elevatissima efficienza di filtrazione, legata anche alla velocità di attraversamento come riportato nella figura seguente. The “dual-voltage” electrostatic filters have very high filtration efficiency, also linked to the crossing speed as shown in the following figure. TABELLA 1: EFFICIENZA FILTRAZIONE a 1m/s e 2m/s FE600 Table 1: Filtration efficiency 1m/s and 2m/s FE600 L’efficienza di filtrazione è dunque non inferiore a E10 (ex H 10) ovvero la classe The filtration efficiency therefore not less than E10 (ex H10),...
Open the catalog to page 8Tale prestazione è ottenuta con perdite di carico pressoché nulle, date dalla geometria costruttiva e legate alla presenza di un prefiltro metallico posto a monte del filtro elettrostatico, con le funzioni di trattenere le particelle più grossolane e This performance is obtained with almost no pressure drop, given by constructive geometry distribuire to the presence of a il flusso d’aria.placed upstream of the electrostatic filter, with and linked omogeneamente metal pre-filter the function of retaining the coarsest particles and distributing airflow uniformly. TABELLA 2: PERDITE DI CARICO...
Open the catalog to page 9ABBATTIMENTO MICRO ORGANISMI ABATEMENT ono attiviMICRO-ORGANISMS muffe, smog, virus, batteri su pollini, polveri fini, toner, entato nella letteratura tecnica ed in base a prove specifiche e Electrostatic filters are active on pollen, fine (ILH Berlin toner,elettrostatici sono attivi su sistemipolveri fini, toner, muffe dust, e San smog, viruses,di Pavia) i pollini, di filtrazione I filtri mold, Matteo bacteria ENERGY and tobacco smoke. n grado diAs documented in theflusso d’aria trattata, con una tipica eliminare dal technical literature CONSUMPTION e fumo di tabacco. and on the basis of...
Open the catalog to page 10ECONOMIC ANALYSIS High performances of electrostatic filters are accompanied by important benefits mainly due to: • Pressure drop on the airflow side is absolutely modest, determined almost exclusively by the metal prefilters G2 or G4. This results in a significant reduction in the energy consumption for ventilation, with the filtration efficiency that stays constant throughout the operating cycle; • The life cycle of the filters is equal to the life of the machine itself (15-20 years): the soiling of the electrostatic filter is signaled by a sensor that allows to program its periodic...
Open the catalog to page 11Table 3: Pay back air treatment unit with use of electrostatic filters FEATURES OF UNIT Heat recovery of thermodynamic type Freecooling Air flow inlet/recovery Effective prevalence of inlet Effective prevalence of recovery Rooftop air-to-air heat pump OPERATION PROFILE Hours/day of operation Working days per week Weeks/year of operation Total annual hours MAINTENANCE PROFILE Average electricity price Price/labor for filter maintenance PAYBACK CALCULATION Efficiency of main filtration stage Efficiency of second stage filtration Surplus unit price with electrostatic filter option SUPPLY FAN...
Open the catalog to page 12CONCLUSIONS Electrostatic filtration systems are already widely used and tested in civil and industrial environments. Based on the phenomenon of electrostatic precipitation, this type of filtration is characterized by: 1. 2. 3. 4. Very high filtration efficiency, with yields greater than 99%. Contemporary abatement of microorganisms such as bacteria, yeasts, molds and germs. Reliable pressure drop through the filter. The life cycle of the filters is equal to the useful life of the entire unit, with minimal maintenance requirements. 5. Very high level of product reliability. This allows for...
Open the catalog to page 13All Expansion Electronic catalogs and technical brochures
-
Serie c
8 Pages
-
C series
8 Pages
-
RAC
2 Pages
-
M series
14 Pages
-
AIR SPONGE FILTER
2 Pages
-
CP500
4 Pages
-
FCP SYSTEM
2 Pages
-
frame holder
2 Pages
-
FE SYSTEM
8 Pages
-
GRANULAR ACTIVE CARBON
2 Pages
-
LABYRINTH FILTER
2 Pages
-
carbox
2 Pages
-
FI SYSTEM
2 Pages
-
FX SYSTEM
2 Pages
-
Ecokitchen
8 Pages
-
UCO600-800
2 Pages
-
UC400-600
2 Pages
-
UC800
2 Pages
-
UC1200
12 Pages
-
PF METAL COMPACT
2 Pages
-
IONIZER
2 Pages
-
PROLIFE
2 Pages
-
REOCLEAN
2 Pages
-
FEL SYSTEM
4 Pages
-
FEM
2 Pages
-
ECOLIGHT
8 Pages