Key Features
  • Pol-Mux OSNR measurement capability for 40G and 100G coherent signals, compliant with IEC 61282-12 standard.
  • Flexibility to analyze WDMs, EDFAs, drift, spectral transmittance, FP and DFB lasers.
  • Automatic impairment identification for faster troubleshooting.
  • Compliant with ITU-T G.697 recommendation.
  • Fast, accurate scans with no compromise on dynamic range or resolution bandwidth.
  • Remote control via GPIB or LAN using SCPI commands.
  • One-button operation for easy setup and automatic measurement.
Unique Pol-Mux OSNR Measurement Technology

OSNR is a key performance indicator in WDM networks, providing a multichannel assessment of signal quality quickly. EXFO’s in-band OSNR addresses challenges in ROADM or 40 Gbit/s systems. The Pol-Mux OSA is the first third-party instrument for Pol-Mux OSNR measurements, offering a commissioning assistant for accurate ASE OSNR measurements.

Impairment Identification for Faster Troubleshooting

EXFO’s WDM Investigator provides detailed information about signal and noise for each channel, identifying impairments like crosstalk and nonlinear effects, and assessing their severity.

High Resolution for Dense Signal Analysis

The IQS-5240BP offers 33 pm resolution bandwidth, allowing analysis of densely spaced signals, including 25 GHz ITU-grid WDM signals, with high accuracy.

Analyze Any WDM Network

The IQS-5240S-P/BP OSA series supports DWDM applications and all channel spacings from 12.5 GHz DWDM to CWDM, ensuring no-compromise performance.

Flexible and Powerful Automation

With the IQS-600 platform’s Windows-based architecture, the OSA test modules can be controlled remotely, with easy setup and configuration storage.

Accurate Spectral Transmittance

The Spectral Transmittance software feature compares filtered wavelengths to nominal ones, showing insertion loss, channel isolation, and bandwidth at different power levels.

In-Depth DFB Laser Analysis

Characterize DFB laser sources for central wavelength, peak power, bandwidth, and more.

Advanced EDFA Analysis

Optimize EDFAs by measuring gain per channel, noise figure, gain flatness, and gain slope.

Drift Measurements

Monitor power, wavelength, and OSNR over time, with alarm notifications for threshold crossings.

EXFO Connect

Automated asset management with cloud storage for streamlined test operations.

Specifications
  • Optical rejection ratio at 1550 nm: 35-50 dB depending on spacing.
  • Dynamic range: -80 to +18 dBm per channel.
  • Wavelength range: 1250 to 1650 nm.
  • Resolution bandwidth: 0.065 to 0.033 nm.
Ordering Information

Options for polarization controller and software features like advanced measurement mode and WDM Investigator.

See more

Catalog excerpts

IQS-5240S-P/BP Optical Spectrum Analyzers-1

Feature(s) of this product is/are protected by one or more of : US patents 6,612,750; US patents 8,373,852; US patent 6,636,306 and equivalent patents pending and granted in other countries; US patent 8,358,930 and equivalent patents pending and granted in other countries; US patent 8,787,753; US patent 8,364,034 and equivalent patents pending and granted in other countries; US patent 9,438,336 and equivalent patents pending and/or granted in other countries; patent appl. US 2014/0086574 A1; and US design patent D737,429. Highly accurate, easy-to-use intelligent optical spectrum analyzers (OSAs) for current and next-generation networks. KEY FEATURES Pol-Mux OSNR measurement capability for 40G and 100G coherent signals, compliant with the IEC 61282-12 standard (under revision) Compliant with Recommendation ITU-T G.697 Fast, accurate scans—no compromise on dynamic range or resolution bandwidth Flexibility to analyze WDMs, EDFAs, drift, spectral transmittance, FP and DFB lasers GPIB or LAN remote control using SCPI commands Automatic impairment identification for faster troubleshooting One-button operation for easy setup and automatic measurement COMPLEMENTARY PRODUCTS High-Speed Multiservice Test Module IQS-88100NGE Power Blazer SPEC SHEET IQS-5240S-P/BP Optical Spectrum Analyzer

 Open the catalog to page 1
IQS-5240S-P/BP Optical Spectrum Analyzers-2

IQS-5240S-P/BP Optical Spectrum Analyzers UNIQUE POL-MUX OSNR MEASUREMENT TECHNOLOGY OSNR has long been recognized as a key performance indicator in wavelength-division multiplexing (WDM) networks, because it provides a multichannel assessment of signal quality in a very short period of time. In addition, OSNR can predict bit error rate (BER) within just a few minutes, while typical BER tests must run for hours or days. The IEC 61280-2-9 standard defines OSNR measurement as the power ratio between the signal power and the noise at half the distance between the peaks. However, in ROADM or 40 Gbit/s...

 Open the catalog to page 2
IQS-5240S-P/BP Optical Spectrum Analyzers-3

IQS-5240S-P/BP Optical Spectrum Analyzers ANALYZE ANY WDM NETWORK The IQS-5240S-P/BP OSA series covers your DWDM applications and all channel spacings from 12.5 GHz DWDM to CWDM. This is what we call “no-compromise performance,” whatever your network specificities and testing requirements may be. FLEXIBLE AND POWERFUL AUTOMATION Thanks to the IQS-600 platform’s Windows-based open architecture and Ethernet connectivity, the IQS-5240S-P/BP OSA test modules can be easily controlled remotely using SCPI commands. QUICKER SETUPS–EASIER TESTING The application software has been designed to optimize...

 Open the catalog to page 3
IQS-5240S-P/BP Optical Spectrum Analyzers-4

IQS-5240S-P/BP Optical Spectrum Analyzers ADVANCED EDFA ANALYSIS Since amplifiers are critical elements in all networks, it is crucial to ensure that they are optimized, that the gain is well-distributed and that the output power is flat. Now, you can further optimize EDFAs by measuring key parameters such as gain per channel, noise figure, gain flatness and gain slope. More importantly, you can save and print this precious information. DRIFT MEASUREMENTS You can monitor power, wavelength and OSNR over time. Follow the evolution of these critical parameters, set relative or absolute thresholds...

 Open the catalog to page 4
IQS-5240S-P/BP Optical Spectrum Analyzers-5

SPECTRAL MEASUREMENT Wavelength range (nm) Wavelength uncertainty (nm) b Reference Resolution bandwidth (FWHM) (nm) f Wavelength linearity (nm) Wavelength repeatability 2a (nm) POWER MEASUREMENT Dynamic range (dBm) (per channel) b Maximum total safe power (dBm) Absolute power uncertainty (dB) i Power repeatability 2a (dB) d, g OPTICAL MEASUREMENT Optical rejection ratio at 1550 nm (dB) at 0.2 nm (25 GHz) at 0.4 nm (50 GHz) Channel spacing PDL at 1550 nm (dB) ORL (dB) IQS-5240S-P/BP Optical Spectrum Analyzers POL-MUX OSNR MEASUREMENT Notes a. All specifications are for a temperature of 23 °C ±...

 Open the catalog to page 5
IQS-5240S-P/BP Optical Spectrum Analyzers-6

GENERAL SPECIFICATIONS Temperature operating 0 °C to 40 °C (32 °F to 104 °F) Relative humidity 0 % to 95 % noncondensing Connectors EI (EXFO UPC Universal Interface) EA (EXFO APC Universal Interface) Size (H x W x D) IQS-5240S module 125 mm x 112 mm x 282 mm (4 15/16 in x 4 7/i6 in x 11 1/8 in) Weight IQS-5240S module 1.5 kg (3.3 lb) IQS-5240BP module 1.7 kg (3.8 lb) LASER SAFETY ORDERING INFORMATION IQS-5240S-P/BP Optical Spectrum Analyzers SELECTION GUIDE OSA Module CWDM ROADM+ 40 Gbit/s network Class 1 laser product in compliance with standards IEC 60825-1:...