IRt/C.4AXLM - Infrared Temperature Sensor
1Pages

{{requestButtons}}

Catalog excerpts

IRt/C.4AXLM - Infrared Temperature Sensor - 1

Product Overview The IRt/c.4AXLF features: • Infrared Thermocouple IRt/c • Non-contact • Self Powered • Intrinsically Safe • Repeatability 0.02°F (0.01°C) • Interchangeability ±1% • Resolution approx. 0.0001°C • Extra long focus \Range Adjustment Screw | AIR PURGE/COOL FITTING \ AIR PURGE PATH '—T/C WIRE #10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.. MOUNTING SCREWS PROVIDED dia. at focal plane. Spot size increases with approx 5 deg included angle away from focal plane. Technical Data Target SurfaceType Sensing Range Optimum Range Selections Minimum Spot Size Field-of-View at > min. spot Spectral Response Output Impedance Cable Dimensions Weight Housing Air Purge Lo E (metal) 1700 to 3500°F (930 to 1930°C) One model each R, S: adjustable over entire sensing range, output tables available 0.19" (4.8 mm) at 8" (200 mm) from sensor 5° approximately 2 to 20 p 0.1 to 5 p 10 Kohms approx Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon sheathed, rated to 392°F (200°C) continuous service 8.375" x 1.375" Dia. (213 x 35 mm) 20 oz (570 g) with cable Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided Set-up and calibration instructions For all IRt/c Models with "A" in model designation (IRt/c.xxxA) 1. Connect air purge first if installing in process already at operating temperature. Provide minimum 5 psig (30 kPa) air pressure. 2. Install IRt/c and align to view the desired target. Bring target to operating temperature if not already there. Connect leads to readout device to be used (controller, PLC, etc.). 3. If the target temperature is not known, measure the target temperature with an accurate reference. Remove the setscrew to expose the calibration screw. Adjust the calibration screw to obtain reading desired. Replace the setscrew cover when complete. For final process adjustments, the ZERO or OFFSET adjustments available on readout devices can be conveniently used. • Installation and calibration complete. • To maximize the linear range, see Tech Note #70. • Calibration screw operates like a radio volume control: clockwise increases signal. Exergen Global offices:

Open the catalog to page 1

All Exergen Global catalogs and technical brochures

  1. SmartIRt/c

    2 Pages

  2. Micro IRt/c

    1 Pages