IRt/C.4AXLM - Infrared Temperature Sensor

IRt/C.4AXLM - Infrared Temperature Sensor

Product catalog summary
Contact Information:
Exergen Global offices are located in the Netherlands and the USA. The Netherlands office is at Pastoor Clercxstraat 26, 5465 RH Veghel, with phone +31 (0)413 376 599 and fax +31 (0)413 379 310. The USA office is at 400 Pleasant Street, Watertown, MA 02472, with phone +1 617 649 6322 and fax +1 617 923 9911.
Product Overview:
The IRt/c.4AXLF is an infrared thermocouple sensor that is non-contact, self-powered, and intrinsically safe. It offers a repeatability of 0.02°F (0.01°C) and interchangeability of ±1%. The resolution is approximately 0.0001°C. It is designed for both high emissivity (non-metal) and low emissivity (metal) surfaces, with a sensing range of 900 to 3500°F (480 to 1930°C) for non-metals and 1700 to 3500°F (930 to 1930°C) for metals. The minimum spot size is 0.19” (4.8 mm) at 8” (200 mm) from the sensor, with a field-of-view of approximately 5°.
Technical Specifications:
The sensor has a spectral response of 2 to 20 μ for non-metals and 0.1 to 5 μ for metals. It features an output impedance of approximately 10 Kohms and comes with a twisted shielded pair cable of base thermocouple material, 3 ft (0.9 m) in length, Teflon sheathed, rated to 392°F (200°C) for continuous service. The dimensions are 8.375” x 1.375” Dia. (213 x 35 mm) and it weighs 20 oz (570 g) with the cable. The housing is stainless steel, hermetically sealed, exceeding NEMA 4,4x; IP65,67 standards, and is intrinsically safe.
Installation and Calibration:
For models with an 'A' in the designation, connect the air purge first if the process is already at operating temperature, ensuring a minimum of 5 psig (30 kPa) air pressure. Install and align the IRt/c to view the target, bringing it to operating temperature if necessary. Connect leads to the readout device. If the target temperature is unknown, measure it with a reference, adjust the calibration screw to the desired reading, and replace the setscrew cover. Use ZERO or OFFSET adjustments on readout devices for final process adjustments. The calibration screw functions like a radio volume control, increasing the signal when turned clockwise.
See more

Catalog excerpts

IRt/C.4AXLM - Infrared Temperature Sensor-1

Product Overview The IRt/c.4AXLF features: • Infrared Thermocouple IRt/c • Non-contact • Self Powered • Intrinsically Safe • Repeatability 0.02°F (0.01°C) • Interchangeability ±1% • Resolution approx. 0.0001°C • Extra long focus \Range Adjustment Screw | AIR PURGE/COOL FITTING \ AIR PURGE PATH '—T/C WIRE #10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.. MOUNTING SCREWS PROVIDED dia. at focal plane. Spot size increases with approx 5 deg included angle away from focal plane. Technical Data Target SurfaceType Sensing Range Optimum Range Selections Minimum Spot Size Field-of-View at > min. spot Spectral Response Output Impedance Cable Dimensions Weight Housing Air Purge Lo E (metal) 1700 to 3500°F (930 to 1930°C) One model each R, S: adjustable over entire sensing range, output tables available 0.19" (4.8 mm) at 8" (200 mm) from sensor 5° approximately 2 to 20 p 0.1 to 5 p 10 Kohms approx Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon sheathed, rated to 392°F (200°C) continuous service 8.375" x 1.375" Dia. (213 x 35 mm) 20 oz (570 g) with cable Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided Set-up and calibration instructions For all IRt/c Models with "A" in model designation (IRt/c.xxxA) 1. Connect air purge first if installing in process already at operating temperature. Provide minimum 5 psig (30 kPa) air pressure. 2. Install IRt/c and align to view the desired target. Bring target to operating temperature if not already there. Connect leads to readout device to be used (controller, PLC, etc.). 3. If the target temperature is not known, measure the target temperature with an accurate reference. Remove the setscrew to expose the calibration screw. Adjust the calibration screw to obtain reading desired. Replace the setscrew cover when complete. For final process adjustments, the ZERO or OFFSET adjustments available on readout devices can be conveniently used. • Installation and calibration complete. • To maximize the linear range, see Tech Note #70. • Calibration screw operates like a radio volume control: clockwise increases signal. Exergen Global offices:

 Open the catalog to page 1