Exergen Global offices are located in the Netherlands and the USA. The Netherlands office is at Pastoor Clercxstraat 26, 5465 RH Veghel, with phone and fax numbers +31 (0)413 376 599 and +31 (0)413 379 310, respectively. The USA office is at 400 Pleasant Street, Watertown, MA 02472, with phone and fax numbers +1 617 649 6322 and +1 617 923 9911, respectively.
Technical Specifications:
The IRt/c.100A Base Model is designed for non-contact temperature measurement. It is suitable for both high emissivity (non-metal) and low emissivity (metal) surfaces, with a sensing range of 1000 to 5000°F (540 to 2760°C) for non-metals and 1500 to 5000°F (820 to 2760°C) for metals. The device offers adjustable optimum range selections and features a minimum spot size at various distances, with a field-of-view of approximately 100:1 (0.6°). The spectral response ranges from 2 to 20 μ for non-metals and 0.1 to 5 μ for metals. The output impedance varies between 6 to 13 Kohms for non-metals and 9 to 18 Kohms for metals. The sensor is housed in stainless steel, hermetically sealed, and exceeds NEMA 4,4x; IP65,67 standards, ensuring it is intrinsically safe.
Product Features:
The IRt/c.100A features an infrared thermocouple, is self-powered, and offers repeatability of 0.02°F (0.01°C) with interchangeability of ±1%. It provides a resolution of approximately 0.0001°C and includes a built-in air purge with a cooling capacity up to 400°F (200°C).
Set-up and Calibration Instructions:
For installation, connect the air purge first if the process is already at operating temperature, ensuring a minimum of 5 psig (30 kPa) air pressure. Align the IRt/c to view the target and connect leads to the readout device. If the target temperature is unknown, measure it with a reference, adjust the calibration screw to the desired reading, and replace the setscrew cover. Final adjustments can be made using the ZERO or OFFSET adjustments on readout devices. The calibration screw functions like a radio volume control, increasing the signal when turned clockwise.
See more

Catalog excerpts

IRT/C.100A BASE MODEL-1

Product Overview IRt/c.100A Base Model The IRt/c.100A features: • Infrared Thermocouple IRt/c • Non-contact • Self Powered • Intrinsically Safe • Repeatability 0.02°F (0.01°C) • Interchangeability ±1% • Resolution approx. 0.0001°C • 100:1 Field of View Target SurfaceType Sensing Range Optimum Range Selections Minimum Spot Size at dist. (with supplied apertures) Field-of-View at > min. spot Spectral Response Output Impedance Cable Dimensions Weight Housing Air Purge Hi E (non-metal) Lo E (metal) One model each R,S: adjustable over entire sensing range, output tables available At distance, with supplied apertures: No Aperture: 0.8" (20 mm) at <80" (2000 mm) J4" Aperture: 0.5" (13 mm) at <50" (1270 mm) %" Aperture: 0.25" (6 mm) at <25" (635 mm) At > min. spot: 100:1 (0.6°) approximately 2 to 20 ^ 0.1 to 5 ^ 6 to 13 Kohms approx 9 to 18 Kohms approx Twisted shielded pair of base thermocouple material (R,S,etc.), 3 ft (.9 m) std length, Teflon sheathed, rated to 392°F (200°C) continuous service 10.5" x 1.375" Dia. (265 x 35 mm) 20 oz (570 g) with cable Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided For all IRt/c Models with "A" in model designation (IRt/c.xxxA) 1. Connect air purge first if installing in process already at operating temperature. Provide minimum 5 psig (30 kPa) air pressure. 2. Install IRt/c and align to view the desired target. Bring target to operating temperature if not already there. Connect leads to readout device to be used (controller, PLC, etc.). 3. If the target temperature is not known, measure the target temperature with an accurate reference. Remove the setscrew to expose the calibration screw. Adjust the calibration screw to obtain reading desired. Replace the setscrew cover when complete. For final process adjustments, the ZERO or OFFSET adjustments available on readout devices can be conveniently used. • Installation and calibration complete. • To maximize the linear range, see Tech Note #70. • Calibration screw operates like a radio volume control: clockwise increases signal. [email protected] www.exergenglobal.com

 Open the catalog to page 1