Product Overview
The DX501-RS is a handheld precision infrared thermometer known for its high accuracy, speed, and NIST traceability. It features a resolution and repeatability of 0.1°C, and an automatic emissivity compensation system, making it suitable for a wide range of temperature measurements from -50 to 550°F (-45 to 287°C).
Technical Specifications
  • Temperature Range: -50 to 550°F (-45 to 287°C)
  • Field of View: 1:1 (approx. 53°)
  • Operating Temperature: 32 to 122°F (0 to 50°C)
  • Minimum Spot Size: 0.25” (6 mm)
  • Spectral Response: 2 to 20 μ
  • Linearity Error: ± 1% of reading
  • Emissivity Adjustment: Automatic
  • Repeatability: ± 0.1°F (0.1°C)
  • Resolution: 0.1°F (0.1°C)
  • Calibration Requirement: None
  • Response Time: Approximately 0.1 sec
  • Power: 9V Alkaline Battery
  • Remote Sensor: Yes
Automatic Emissivity Compensation System
The DX-Series employs a unique system that ensures accurate temperature readings by creating a blackbody at the measurement location, thus correcting for emissivity variations and eliminating contact errors.
Advantages of DX-Series over Conventional Devices
  1. No Emissivity Errors: The system automatically compensates for emissivity, unlike conventional devices that require manual settings.
  2. No Emissivity Shift Errors: The device remains accurate across different temperatures, unlike conventional IR thermometers.
  3. No User Adjustment Errors: Eliminates errors from user-set emissivity adjustments.
  4. No Background Reflection Errors: Accurate readings despite ambient temperature changes.
  5. No Contact Errors: Unlike contact devices, it measures actual surface temperature without needing to match probe and surface temperatures.
  6. No Friction Heating Errors: Avoids errors from frictional heating on moving surfaces.
  7. No Heat Sinking Errors: Prevents errors from heat conduction issues in non-metals.
  8. No Time-Based Errors: Provides rapid measurements, unlike slower contact probes.
See more

Catalog excerpts

DX501-RS - Handheld Precision IR Thermometer-1

1/2 Infrared Temperature Sensors DATASHEET Product Overview The DX501-RS features: • Handheld Precision IR Thermometer • High Accuracy • High Speed • NIST Traceable • Interchangeability ±1% • Resolution 0,1°C • Repeatability 0,1°C • Remote Sensor Technical Data Temperature Range Operating Temperature Calibration Requirement Minimum Spot size Response time Spectral Response °F/°C Conversion Linearity Error Emissivity Adjustment Automatic Emissivity Compensation System Remote Sensor Emissivity Error ± 1% maximum of difference between target temperature and instrument temperature when touching, for emissivity of 0,8 to 1,0 Automatic Emissivity Compensation System The DX-Series is an entirely different type of instrument than conventional temperature measuring devices. Designed specifically for the highest possible accuracy, it is the only infrared instrument whick can be certified with NIST-traceable accuracy on real surfaces of unknown emissivity, while remaining completely free of the contact errors and heat sinking errors of contact devices. Recessed cone traps all emitted surface radiation, adn blocks out any radiation from environment Actual measurement area is in the center, well away from the area contacted by the edge of the cone Reflective cone automatically corrects for emissivity variations by creating an actual blackbody at the precise location of measurement Only a thin lip of material actually contacts the target, thus minimizing heat transfer Figure 1. Unique Automatic Emissivity Compensation System (AECS) produces accurate temperatures everywhere the infrared probe is placed by creating in own blackbody The sensing area of the DX Scanner is equipped with a reflective surface to correct for emissivity variations Exergen Global offices: The Netherlands Pastoor Clercxstraat 26 5465 RH Veghel Tel: +31 (0)413 376 599 Fax: +31 (0)413 379 310

 Open the catalog to page 1
DX501-RS - Handheld Precision IR Thermometer-2

2/2 Infrared Temperature Sensors DATASHEET 8 reasons the DX Series of handheld infrared scanners from EXERGEN are Superior to Conventional Devices 1. No emissivity The true emissivity of a surface can never be accurately determined by conventional infrared devices. Without Exergen’s Automatic Emissivity Compensation System, IR devices with a pre-set emissivity setting can only display an approximate temperature over their entire temperature range. The accuracy specifications given by most manufacturers are only for a “blackbody” calibration and do not hold outside laboratory conditions. Blackbody...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.