2023 Flow Aid System
28Pages

{{requestButtons}}

Catalog excerpts

2023 Flow Aid System - 1

Unit exchange chart Particle Frequency Revolution speed Centrifugal force Vibratory force ・ Torque Torque Stroke energy ・ Impulsive force Pressure Horse poewer Output ・ Acceleration mass measurement tenperature Unit1 Hz min-1 kN N・cm N・m kg・m/s MPa Pa MPa MPa kW m/s2 g kg inch feet ℃ Unit2 v.p.m r.p.m kgf kgf・cm kgf・m kg・m/sec kgf/cm2 Mpa PSI BAR PS G oz lb mm cm ° F EXEN CORPORATION 1-17-13, Hamamatsu-cho, Minato-ku, Tokyo, Japan, 105-0013 TEL.81-3-3434-8452 FAX.81-3-3434-8368 Contact: commerce@exen.co.jp

Open the catalog to page 1
2023 Flow Aid System - 2

Automatic hammering device with adjustable impact force TROUBLE PHENOMENON Bridging occurs when material clings to Ratholing occurs when material flows the wall or compacts above the only above the discharging opening and discharge opening at hopper bottom, forms a tube besides the hopper wall and material flow in upper area is leaving the hopper filled with "dead" material which will not be discharged. Arching occurs when material in hopper Material which is easy to cling or bottom flows out from the discharging opening and an arch is formed which is adheres to hopper wall and refuses to...

Open the catalog to page 2
2023 Flow Aid System - 3

Automatic hammering device with adjustable impact force TROUBLE PHENOMENON Bridging occurs when material clings to Ratholing occurs when material flows the wall or compacts above the only above the discharging opening and discharge opening at hopper bottom, forms a tube besides the hopper wall and material flow in upper area is leaving the hopper filled with "dead" material which will not be discharged. Arching occurs when material in hopper Material which is easy to cling or bottom flows out from the discharging opening and an arch is formed which is adheres to hopper wall and refuses to...

Open the catalog to page 3
2023 Flow Aid System - 4

Installed directly on hoppers, silos and chutes to eliminate blockages. While the RKV series transmits impact force indirectly through the knocker base, RKD series transmits impact force directly to the object by the piston. The base of RKV60PBR, RKV80PAR, and RKV100PAR is designed for round surface. ■Specification (Metric) Model *Reinforcing rib is included in RKV60PB and larger model only, and fall prevention wire and shackle are included in all models. Stroke Cycle (time/min) Impulsive Force ■Specification (Metric) Converts into Hammer pound (lb) *Reinforcing rib, fall prevention wire and...

Open the catalog to page 4
2023 Flow Aid System - 5

Installed directly on hoppers, silos and chutes to eliminate blockages. While the RKV series transmits impact force indirectly through the knocker base, RKD series transmits impact force directly to the object by the piston. The base of RKV60PBR, RKV80PAR, and RKV100PAR is designed for round surface. ■Specification (Metric) Model *Reinforcing rib is included in RKV60PB and larger model only, and fall prevention wire and shackle are included in all models. Stroke Cycle (time/min) Impulsive Force ■Specification (Metric) Converts into Hammer pound (lb) *Reinforcing rib, fall prevention wire and...

Open the catalog to page 5
2023 Flow Aid System - 6

Body, base, mounting bolts and other parts of RKVS series are made of stainless steel and suitable for food, chemical, and pharmaceutical industries where corrosion resistance and sanitation are required. Also, this model is suitable for industry related to rechargeable battery. Stainless steel knocker Hygienic knocker (Sanitary Tri-clamp) Converts into Hammer pound (lb) Mini Hammer ■Specification (Imperial) Impulsive Force (ft lbf/s) ・ 2.2 ∼3.6 4.3∼5.8 Converts into Hammer pound (lb) Mini Hammer Below0.6 *Reinforcing rib is included in RKVS60 only, and fall prevention wire and shackle are...

Open the catalog to page 6
2023 Flow Aid System - 7

Body, base, mounting bolts and other parts of RKVS series are made of stainless steel and suitable for food, chemical, and pharmaceutical industries where corrosion resistance and sanitation are required. Also, this model is suitable for industry related to rechargeable battery. Stainless steel knocker Hygienic knocker (Sanitary Tri-clamp) Converts into Hammer pound (lb) Mini Hammer ■Specification (Imperial) Impulsive Force (ft lbf/s) ・ 2.2 ∼3.6 4.3∼5.8 Converts into Hammer pound (lb) Mini Hammer Below0.6 *Reinforcing rib is included in RKVS60 only, and fall prevention wire and shackle are...

Open the catalog to page 7
2023 Flow Aid System - 8

Piping references Controls air knocker only with compressed air (no electricity required). Knocker's operation interval can be changed easily by the speed controller. Operates up to 3 air knockers with relay piping. Using 3-way solenoid valve AG44 (Maximum 5 knockers) ■Specification (Metric) Model Approx Dimensions (LXWXH)(mm) Working fluid Working times Temperature (℃) Per/min. Dammy pipe Power supply Approx Dimensions (LXWXH)(inch) Dummy pipe Filter regulator Protection class *Knocker can control automatically by installing solenoid valve (AG43-02-4-02G) before AOC-1B. Stroke cycle Approx...

Open the catalog to page 8
2023 Flow Aid System - 9

Piping references Controls air knocker only with compressed air (no electricity required). Knocker's operation interval can be changed easily by the speed controller. Operates up to 3 air knockers with relay piping. Using 3-way solenoid valve AG44 (Maximum 5 knockers) ■Specification (Metric) Model Approx Dimensions (LXWXH)(mm) Working fluid Working times Temperature (℃) Per/min. Dammy pipe Power supply Approx Dimensions (LXWXH)(inch) Dummy pipe Filter regulator Protection class *Knocker can control automatically by installing solenoid valve (AG43-02-4-02G) before AOC-1B. Stroke cycle Approx...

Open the catalog to page 9
2023 Flow Aid System - 10

AIR KNOCKER INSTALLATION GUIDE AIR KNOCKER INSTALLATION GUIDE Be sure to follow the instruction manual when installing the air knocker. Installation 1/2L Welding the reinforcing plate For large cone, pyramid hopper For adherence to the wall or pipe. In case of poor fluidity. Hang and fix the knocker with fall prevention wire and shackle to prevent it from falling. Bolt set Round Type Designated dimension (inch) L︓Bolt length t︓Plate thickness Installation bolt Specified dimensions 5/32 or more - less than 15/64 15/64 or more - less than 5/16 4 or more - less than 6 *( )Stainless steel material...

Open the catalog to page 10
2023 Flow Aid System - 11

AIR KNOCKER INSTALLATION GUIDE AIR KNOCKER INSTALLATION GUIDE Be sure to follow the instruction manual when installing the air knocker. Installation 1/2L Welding the reinforcing plate For large cone, pyramid hopper For adherence to the wall or pipe. In case of poor fluidity. Hang and fix the knocker with fall prevention wire and shackle to prevent it from falling. Bolt set Round Type Designated dimension (inch) L︓Bolt length t︓Plate thickness Installation bolt Specified dimensions 5/32 or more - less than 15/64 15/64 or more - less than 5/16 4 or more - less than 6 *( )Stainless steel material...

Open the catalog to page 11

All EXEN Corporation catalogs and technical brochures

  1. viback