Catalog excerpts
Stay up to date by visiting our website and take advantage of the information and services we didn’t have room to display in this catalog. Where you can • Chat live with our problem solving, technical expert Application Engineers • Watch product videos to learn more about the features and benefits of our engineered products • Quickly order online with a purchase order or credit card (US & Canada) • Access product presentation slides you can use to educate others • Find International Distributors all across the world Access our Knowledge Base to • Download 3D models and CAD drawings in...
Open the catalog to page 2Terms and Conditions (U.S. and Canada Only) Terms: ICC (International Chamber of Commerce) INCOTERM 2010: Delivery Ordering: Remit to address (payments only): Tax: Technical Assistance: Warranty: * 5 Year Warranty applies to compressed air products only. A 1 Year Warranty applies to all accessories and electrically powered products. EXAIR’s Unconditional Guarantee: Copyright Restrictions: 11510 Goldcoast Dr. Cincinnati, Ohio 45249-1621 Phone Number: (513) 671-3322 Fax Number: (513) 671-3363 E-mail: techelp@exair.com Web Site: www.exair.com Net 30 days upon credit approval, Visa, MasterCard,...
Open the catalog to page 3Cabinet Cooler® Systems MOBILE VIEW Cabinet Cooler® Systems Stop electronic control downtime due to heat, dirt, and moisture! Cabinet Coolers maintain NEMA 4, 4X, and 12 integrity. All Cabinet Coolers are and/or compliant! What is an EXAIR Cabinet Cooler System? A low cost, reliable way to cool and purge electronic control panels. EXAIR Cabinet Coolers incorporate a vortex tube to produce cold air from compressed air - with no moving parts. The compact Cabinet SCAN & WATCH the video! https://exair.co/04-cvvid Cooler can be installed in minutes through a standard electrical knockout. NEMA...
Open the catalog to page 4Cabinet Cooler® Systems Mounting How The Cabinet Cooler Works Compressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. (For more information on vortex tube operation, see page 200.) Hot air from the vortex tube is muffled and exhausted Hot Air from Vortex Tube through the vortex tube exhaust. The cold air is discharged into the control cabinet through the cold air distribution kit. The displaced hot air in the cabinet rises and exhausts to atmosphere Compressed Air Supply Cabinet Air Exhaust Cold Air from Vortex Tube through the...
Open the catalog to page 5Cabinet Cooler® Systems Selecting The Right Model – Know Your System Options (continued) ETC™ Electronic Temperature Control EXAIR’s digital ETC (Electronic Temperature Control) provides precise temperature control for your electrical enclosure. It can accurately maintain a constant temperature that is slightly under the maximum rating of the electronics, permitting just enough cooling for the electronics without going so cold as to waste compressed air. The LED readout of the ETC displays the internal temperature of the electrical enclosure (°F or °C) that is constantly being monitored by...
Open the catalog to page 6Cabinet Cooler® Systems Filtration: EXAIR Cabinet Cooler Systems include a 5 micron automatic drain water and dirt filter. This filter is critical for protection of electronics from water and dirt in the compressed air line. If oil is present in the compressed air, a coalescing (oil removal) filter, such as EXAlR Model 9005 is recommended. (See page 231) Inlet Air Temperature: Cabinet Cooler Systems provide a 50°F (28°C) temperature drop from supply air temperature when the inlet pressure is 80 PSIG (5.5 BAR). Elevated inlet temperature will produce a corresponding rise in cold air...
Open the catalog to page 7Cabinet Cooler® Systems Sizing Guide - Let us do the work On the following page, EXAIR provides a simple guide to fill in and send to us so we may do the heat load calculations for you and specify a Cabinet Cooler system. You may e-mail the information to techelp@exair.com, call 1-800-903-9247, fill out an online form at exair.com/sizing, use our new calculator at https://exair.co/cccalc_ca or fax the information to 1-866-329-3924. How To Calculate Heat Load for Your Enclosure If you would like to determine the correct model for your enclosure without our assistance, it is first necessary...
Open the catalog to page 8Cabinet Cooler® System Sizing Guide Deliver your Data – Receive a Quote Use this form to gather the information necessary to specify a Cabinet Cooler System and choose a delivery method below. Submit online Online chat with us at Calculate Yourself We’ll respond with our recommended solution within 24 hours. Cabinet Cooler Sizing Guide To: Application Engineering Department, In a hurry? For help NOW, call our Application Engineering Department at 1-800-903-9247 From: Name Company You can fill this form out online at: Phone number 4. * External air temperature now? or °C °F 5. * Internal air...
Open the catalog to page 9Cabinet Cooler® Systems Cabinet Coolers Keep Working at Full Capacity After Seven Years of Near Constant Operation The Problem: A manufacturer of automotive radiators had a problem relating to an overheated motor drive which caused one of their two production lines to come to a stop. They used a refrigerant based air conditioner set on the panel, but the air conditioner began leaking water into the panel. The water got into the motor drive, shorted it out and caused the production line to go down. Not only was production down for 1 month, but the motor drive cost them $20,000 to replace by...
Open the catalog to page 10Cabinet Cooler® Systems NEMA 12 (IP54) Cabinet Cooler Systems 120V Thermostat Control Model # ETC 240V Thermostat Control Model # High Temp Thermostat Control Model # 4315 NEMA 12 (IP54) (Dust, Oil Resistant) ETC 120V Thermostat Control Model # Non-Hazardous Purge Capacity* Thermostat Control Model # Btu/Hr Watts Cabinet Cooler Only Model # Continuous Operation Model # High Temp Continuous Operation Model # NEMA 12 (IP54) (Dust, Oil Resistant) Capacity* Btu/Hr *Cooling capacity at 100 PSIG (6.9 BAR) supply pressure. **With optional cold muffler installed. NEMA 12 (IP54) Cabinet Cooler...
Open the catalog to page 11All EXAIR catalogs and technical brochures
-
Summer 2023 Exair Mail 136
1 Pages
-
Spring 23 Exair Mail 135
2 Pages
-
Fall 2022 Exair Mail 133
2 Pages
-
Catalog 35 - Static Eliminators
28 Pages
-
Catalog 35 - Safety Air Guns
15 Pages
-
Catalog 35 - Optimization
15 Pages
-
Catalog 35 - Air Wipes
12 Pages
-
Catalog 35 - Air Knives
18 Pages
-
Catalog 35 - Air Amplifiers
14 Pages
-
Catalog 35 - Accessories
13 Pages
-
Blowoff Guide
14 Pages