Catalog 32 Cabinet Cooler Systems - 19 Pages

Add to MyDirectIndustry favorites
Catalog 32 Cabinet Cooler Systems

Catalog excerpts

MANUFACTURING INTEL COAT CLEAN rmiTinu COOL CONVEY CONSERVE

 Open the catalog to page 1

Stay up to date by visiting our website and take advantage of the information and services we didn’t have room to display in this catalog. The digital home of Intelligent Compressed Air® products for industry Where you can Chat live with our problem solving, technical expert Application Engineers Watch product videos to learn more about the features and benefits of our engineered products Quickly order online with a purchase order or credit card (US & Canada) Access product presentation slides you can use to educate others Find International Distributors all across the world Access our...

 Open the catalog to page 2

Terms and Conditions . . . . . . . . . . . 4 Efficiency Lab . . . . . . . . . . . . . . . . . . . 5 Standards Compliance. . . . . . . . .208 EXAIR Optimization Minimize compressed air use and detect wasteful leaks 6 Steps to Optimization. . . . . . . . . . . . . . . . . . . . . . .6 Electronic Flow Control . . . . . . . . . . . . . . . . . . . . . . .7 Digital Flowmeter with wireless capability . . . . .10 Digital Flowmeter . . . . . . . . . . . . . . . . . . . . . . . . . .12 Digital Sound Level Meter . . . . . . . . . . . . . . . . . . .15 Ultrasonic Leak Detector. . . . . . . . . . . . ....

 Open the catalog to page 3

Cold Gun Aircoolant Systems Safety air guns use engineered air nozzles for high performance Convey parts, materials and waste with no moving parts Cool machining operations with clean, cold air Chip Shields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 VariBlast® Compact Safety Air Guns . . . . . . . . . . .98 Soft Grip Safety Air Guns. . . . . . . . . . . . . . . . . . . 100 Super Air Scraper . . . . . . . . . . . . . . . . . . . . . . . . . .103 Heavy Duty Safety Air Guns. . . . . . . . . . . . . . . . . 104 Back Blow Safety Air Guns . . . . . . . . . . . . . . . . ....

 Open the catalog to page 4

Terms and Conditions (U.S. and Canada Only) Terms: ICC (International Chamber of Commerce) INCOTERM 2010: Delivery Ordering: Net 30 days upon credit approval, Visa, MasterCard, Discover and American Express. EX WORKS (EXAIR Corporation, 11510 Goldcoast Dr., Cincinnati, Ohio 45249, USA.) All cataloged products are shipped from stock, via U.P.S. within 24 hours after receipt of order. Priority shipment is available upon request. Call 1-800-903-9247 or +1-513-671-3322 Worldwide 8:00 a.m. to 5:00 p.m. ET (Mon. - Fri.) Fax toll free 1-866-329-3924 or +1-513-671-3363 Worldwide E-mail:...

 Open the catalog to page 5

Cabinet Cooler® Systems MOBILE VIEW Cabinet Cooler® Systems Stop electronic control downtime due to heat, dirt, and moisture! Cabinet Coolers maintain NEMA 4, 4X, and 12 integrity. All Cabinet Coolers are and compliant! A Model 4830 NEMA 4 Cabinet Cooler cools a panel with 20°F (-7°C) air while keeping the inside dry. What is an EXAIR Cabinet Cooler System? A low cost, reliable way to cool and purge electronic control panels. EXAIR Cabinet Coolers incorporate a vortex tube to produce cold air from compressed Watch the video! air - with no moving parts. The www.exair.com/ccvideo.htm compact...

 Open the catalog to page 6

Cabinet Cooler® Systems Mounting How The Cabinet Cooler Works Compressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. (For more information on vortex tube Hot Air from Vortex Tube operation, see page 173.) Hot air from the vortex tube is muffled and exhausted through the vortex tube exhaust. The cold air is discharged into the control cabinet through the cold air distribution kit. The displaced hot air in the cabinet rises and exhausts to atmosphere Cold Air from Vortex Tube through the cabinet air exhaust at a slight positive...

 Open the catalog to page 7

ETC Electronic Temperature Control EXAIR’s digital ETC (Electronic Temperature Control) provides precise temperature control for your electrical enclosure. It can accurately maintain a constant temperature that is slightly under the maximum rating of the electronics, permitting just enough cooling for the electronics without going so cold as to waste compressed air. The LED readout of the ETC displays the internal temperature of the electrical enclosure (°F or °C) that is constantly being monitored by a quick response thermocouple. The control activates the solenoid valve (included) when...

 Open the catalog to page 8

Cabinet Cooler® Systems Filtration: EXAIR Cabinet Cooler Systems include a 5 micron automatic drain water and dirt filter. This filter is critical for protection of electronics from water in the compressed air line. If oil is present in the compressed air, a coalescing (oil removal) filter, such as EXAlR Model 9005 is recommended. (See page 201) Inlet Air Temperature: Cabinet Cooler Systems provide a 50°F (28°C) temperature drop from supply air temperature when the inlet pressure is 80 PSIG (5.5 BAR). Elevated inlet temperature will produce a corresponding rise in cold air temperature and...

 Open the catalog to page 9

Sizing Guide - Let us do the work On the following page, EXAIR provides a simple guide to fill in and send to us so we may do the heat load calculations for you and specify a Cabinet Cooler system. You may e-mail the information to techelp@exair.com, call 1-800-903-9247, online chat with us at www.EXAIR.com, or fax the information to 1-866-329-3924. How To Calculate Heat Load for Your Enclosure If you would like to determine the correct model for your enclosure without our assistance, it is first necessary to determine the total heat load to which the control panel is subjected. This total...

 Open the catalog to page 10

Cabinet Cooler® System Sizing Guide Deliver your Data – Receive a Quote Use this form to gather the information necessary to specify a Cabinet Cooler system and choose a delivery method below. MOBILE Submit online Online chat with us at We’ll respond with our recommended solution within 24 hours. Cabinet Cooler Sizing Guide To: From: Application Engineering Department, Name Company FAX number Phone number E-mail Corporation In a hurry? For help NOW, call our Application Engineering Department at 1-800-903-9247 You can fill this form out online at: 6. Maximum external air temperature...

 Open the catalog to page 11

All EXAIR Corporation catalogs and technical brochures

  1. Blowoff Guide