Ex-M Mr. Slim 24/7 Duty
3Pages

{{requestButtons}}

Catalog excerpts

Ex-M Mr. Slim 24/7 Duty - 1

Equipment for Hazardous Areas Explosion proof Ex-M Mr. Slim 24/7 Duty Split Unit Air Conditioners Features • Specially designed for 24/7 optimal cooling and heating duty • ATEX zone 2 and 22 version of indoor and/or outdoor unit. • Operation range from +46°C down to -15°C ambient temperature • Wall mount, Cassette, Ducted or ceiling suspended indoor models • From 3.5 up to 14 kW © II 3G Ex h ic nAC IIB(+H2) T4 Gc (indoor unit) ® II 3G Ex h ic nAC MB T3 Gc (outdoor unit) Applications Best explosion proof climate control solution when stored goods or devices must kept at a certain temperature (range) at all times. For (offshore) storage containers, battery housings, paint storages, analyzer rooms, warehouses containing dangerous goods or production facilities for goods that can cause explosions. Specific design enables defrosting and cooling at the same time. Suitable for the European climate. 24/7 Duty AC model for safe operations in hazardous areas OEM Mitsubishi Electric Mr. Slim series. Specially designed for 24/7 continuous use in Western European Climate. Converted and certified to explosion proof ATEX zone 2 (3G) and 22 (3D) by Ex-Machinery Explosion Proof Equipment B.V. Explosion Safety Specifications (ATEX) 2984 AM Ridderkerk www.ex-machinery.com The Netherlands info@ex-machinery.com

Open the catalog to page 1
Ex-M Mr. Slim 24/7 Duty - 2

Equipment for Hazardous Areas 24/7 Continuous Duty! ^x) Nominal cooling capacity* Nominal heating capacity Indoor unit dimensions (mm) Outdoor unit dimensions (mm) *nominal capacity at 35° degrees ambient temperature. 2984 AM Ridderkerk www.ex-machinery.com The Netherlands info@ex-machinery.com

Open the catalog to page 2
Ex-M Mr. Slim 24/7 Duty - 3

Explosion proof Ex-M Mr. Slim 24/7 Duty Split Unit Air Conditioners Equipment for Hazardous Areas Optional Corrosion protection coating Stainless steel screws ATEX isolating switch ATEX zone 2 or 22 adaption box to connect with 3phase or with 3phase no neutral / 400-440V power supply ATEX zone 2 or 22 Junction box for redundant operation, automatic switch to second unit in case of failure ATEX Wired remote control in rugged casing ATEX Cassette model 3.5 kW – 13.4 kW 11,950 BTU – 49,000 BTU 1 RT – 3.8 RT ATEX Ceiling suspended model 3.5 kW – 13.4 kW 11,950 BTU – 49,000 BTU 1 RT – 3.8 RT...

Open the catalog to page 3

All Ex-Machinery catalogs and technical brochures

  1. Ex-M+52ºC

    3 Pages

Archived catalogs