Catalog excerpts

Control units
Open the catalog to page 1
Control units Introduction Up to 6 channels
Open the catalog to page 2
BCU Control unit Benefits • Compact 3-channel actuator control unit • Single fault safety • Overload and over-temperature protection • Approved for medical applications • Easy to clean • Low standby current Technical data Unit Motor ports (DIN8) Operating device ports (HD15) Battery ports Limit switch ports Single fault safety Encoder processing yes/no yes/no Input voltage Frequency Input current (max) Standby power Output voltage Output current (max) Duty cycle: intermittent Duty cycle: short time Ambient temperature Humidity Degree of protection Approvals
Open the catalog to page 4
Dimensional drawing Connecting diagrams 191 View without connectors interlock Mains cable Connection for 3 actuators Connection hand switch Suitable control units and accessories Operating switches Linear actuators
Open the catalog to page 5
BCU control unit Voltage 5 120 V AC, 60 Hz, class I 8 230 V AC, 50 Hz, class II Mains power supply cable 2J Class II, straight 3,5 m, 2-pole plug, EU (for voltage type 8) 2H Class II, straight 3,5 m, 2-pole plug, UK (for voltage type 8) 2L Class I, straight 3,5 m, 3-pole plug, UL (for voltage type 5) Soft start/stop 0 Hard 3 Medium 6 Soft (on request) 1) 2) TLT is a 2-motor actuator. If simultaneous run is needed, BCP21-CC... is recommended. Reduced lift capability : CPMT-1 up to 3 000 N, CPMT1-2 up to 4 000 N Actuator 1 Actuator 2 Actuator 3
Open the catalog to page 6
VCU Control unit Benefits • Compact 5-channel actuator control unit • Single fault safety • Overload and over-temperature protection • Approved for medical applications • Easy to clean • Low standby current Technical data Unit Motor ports (DIN8) Operating device ports (HD15) Battery ports (DSub9) Limit switch ports (HD15) Single fault safety Encoder processing yes/no yes/no Input voltage Frequency Input current (max) Standby power Output voltage Output current (max) Duty cycle: intermittent Duty cycle: short time Ambient temperature Humidity Degree of protection Approvals Weight without...
Open the catalog to page 8
Dimensional drawing 38 360 Operating voltage display (LED) Suitable control units and accessories Operating switches Linear actuators Hand switch Foot switch Desk switch 1. Two connections for HD15 operating devices 2. HD15 limit switch connection 3. Additional space for mounting 4.
Open the catalog to page 9
Pinning of HD15 limit switch connection Function 24 V DC (common) Switch 1 Switch 2 NC 20–40 V DC, max. 50 mA GND Connecting diagram 2,9 1,3,5,7,9 white/yellow, white/green, grey–pink, black, blue 1 5 2 brown–green 6 10 4 red–blue 6,8,10,11,12,14 violet, red, pink, grey, yellow, brown 15 11 13 green D=20 15 white Pin 1 Pin 2 Pin 3 Pin 4 Accessories Plug Mains cable, 2 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Battery pack 2,7 Ah Rack for 4,5 Ah battery Detachable battery 4,5 Ah Order number Euro Schuko SEV UL...
Open the catalog to page 10
VCU control unit Voltage 5 120 V AC, 60 Hz, class I 8 230 V AC, 50 Hz, class II 9 230 V AC, 50 Hz, class I Number of channels 3 3 channels 5 5 channels Option 1 1 No option (only VCUx3) 2 Prepared for mounting of battery Transformer 1 7 A transformer 3 18 A transformer (for 5-channel version only) VCU parameterization Functionality 11 All channels individually 2 channels simultaneously + 1 21 or 3 individually 22 2 + 2 channels simultaneously + 1 individually 30 All channels simultaneously, only 3-channel version 4 channels simultaneously + 1 individually, 41 only 5-channel version 50 All...
Open the catalog to page 11
SCU Control unit Benefits • Compact 6-channel actuator control unit • Single fault safety • Overload and over-temperature protection • Approved for medical applications • Easy to clean • Low standby current • Remote control RS232 Technical data Unit Motor ports (DIN8) Operating device ports (HD15) Battery ports (DSub9) Limit switch ports (HD15) Single fault safety Encoder processing yes/no yes/no Input voltage Frequency Input current (max) Standby power Output voltage Output current (max) Duty cycle: intermittent Duty cycle: short time Ambient temperature Humidity Degree of protection...
Open the catalog to page 12
38 360 Operating voltage display (LED) Suitable control units and accessories Operating switches Linear actuators Hand switch Foot switch Desk switch Up to 6 connections with DIN8 plug 1. Two connections for HD15 operating devices 2. HD15 limit switch connection 3. Additional space for mounting 4. Data plate software 5. Mains connection
Open the catalog to page 13
Pinning of HD15 limit switch connection on request (needs a customized SCP) Function Switch 1 Switch 2 Switch 3 Switch 4 24 V DC (com) brown/green red/blue violet red white/yellow, white/green, grey/pink, black Optional external power supply for binary outputs Binary output 1 (22-40 V DC/1 A) Binary output 2 (22-40 V DC/1 A) GND for binary outputs 20-24 V DC, max. 50 mA 5 V DC pulsed GND blue pink grey yellow green brown white Connecting diagram Accessories Plug Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Battery...
Open the catalog to page 14
SCU control unit Voltage 1 24 V DC (only for 6-channel version) 5 120 V AC, 60 Hz, class I 9 230 V AC, 50 Hz, class I Number of channels 3 3 channels 6 6 channels Battery 1 None (only for SCU16) 2 Prepared for mounting of battery 3 Under floor 2.7 Ah battery mounted Transformer 0 None (only for SCU16) 3 Standard (AC version) Interface 0 Without RS232 1 With RS232 (only for 6-channel version) SCU parameterization Functionality 11 All channels individually 21 Channel 2+1(+1+1+1) 22 Six (6) channel version 2+2+1+1 Three (3) channel version, all channels 30 synchronously 31 Six (6) channel...
Open the catalog to page 15
MCU Control unit Benefits • Suitable for mobile applications • LED indication for battery charge level • Audible signal for low charge condition Technical data Unit Motor ports Operating device ports Battery ports Limit switch ports Single fault safety Encoder processing yes/no yes/no Input voltage Frequency Input current (max) Standby power Output voltage Output current (max) Duty cycle: intermittent Duty cycle: short time Ambient temperature Humidity Degree of protection Approvals
Open the catalog to page 16All EWELLIX catalogs and technical brochures
-
Linear actuator Runner
6 Pages
-
High power density solution
2 Pages
-
LIFTKIT-OM
8 Pages
-
SLIDEKIT 2.0
12 Pages
-
Ewellix precision ball screws
16 Pages
-
High performance actuator catalogue
304 Pages
-
Linear technology for joining
20 Pages
-
LIFTKIT-0S
8 Pages
-
LIFTKIT-TM
8 Pages
-
Linear modules and systems
50 Pages
-
Precision rail guides catalogue
116 Pages
-
Solutions for imaging equipment
16 Pages
-
Ball Screws
4 Pages
-
Roller screw catalogue
134 Pages
-
THG
6 Pages
-
Electric cylinders CASM-32/40/63
68 Pages
-
Aerodynamic booster actuator
8 Pages
-
Solutions for mobile machinery
20 Pages
-
Linear actuator CAHB series
56 Pages
-
Linear actuator CAJA35C
6 Pages
-
Actuator range catalogue
310 Pages
-
Roller screws catalogue
134 Pages
-
SVC 8x1R 62/62 G3
3 Pages
-
Telescopic pillar TLG
6 Pages
-
Linear actuator Magdrive
6 Pages
-
Telescopic pillar TLC
6 Pages
-
Telescopic pillar TXG
6 Pages
-
Telescopic pillar TFG
6 Pages
-
Telescopic pillar CPMT
8 Pages
-
Telescopic pillar FRE
4 Pages
-
CPMA
10 Pages
-
CPMB
10 Pages
-
LLU catalogue
74 Pages
-
Operating switches
28 Pages
-
CASM 100 - data sheet
38 Pages
-
CASM 100 - Operating manual
28 Pages
-
Profile rail guides catalogue - LLT
116 Pages
-
Fluid power replacement
28 Pages
-
Electric cylinders LEMC
48 Pages
-
Servo actuator SEMC
12 Pages
-
Telescopic pillar TLT
6 Pages
-
Servo pillar CPSM
10 Pages
-
ewellix brochure
5 Pages
-
Linear actuator Ecomag
6 Pages
-
Linear actuator CAMT
10 Pages
-
Linear actuator Matrix series
16 Pages
-
Car transfer unit solutions
12 Pages
-
Electric cylinders CEMC
12 Pages
-
Electric cylinders CASM-25
8 Pages