1. Catalogs
  2. EVOMESURE
  3. EM5010A Environment Monitor
video corpo

EM5010A Environment Monitor
1 /5Pages

EM5010A Environment Monitor

EM5010A Environment Monitor
1 /5Pages

Catalog excerpts

EM5010A Environment Monitor-1

The EM5010A is a unique, versatile and capable Instrument which long-term displays, monitors, surveys and records all sorts of data, delivered by sensors. The sensors might measure virtually all thinkable parameters, as the data and the type of data processed by the EM5010A is defined just by the sensor. With these features, the EM5010A is the perfect instrument for monitoring all kinds of environmental data, like temperature, ambient air pressure, humidity, particulate matters, VOC (volatile organic components), NOx, CO, CO2, strain, height, etc. So it is ideal for monitoring all slow changing values which are in many cases mission critical when producing, storing, running labs etc. But the EM5010A does not stop there. Many sensors come with a built in movement detector. That allows you to identify the cause for your value changes most likely. So finding out, if that temperature peak was caused by the DuT or somebody touching the sensor is just a matter of seconds. Even later on, because the movements are always recorded. Furthermore the EM5010A supports sensors with digital inputs to monitor all sorts of external influences. So you can easily see, if someone switched on the light, opened a door or even see when the AC was working. These digital inputs are equally recorded as the analog values to give you the best possible view of what exactly happened at every time. In mobile use the EM5010A can be fitted with an external GPS sensor, so all measurements are recorded with position data. That allows areal surveillance or fail-proof documentation of the measurement location. As for the instrument EM5010A itself, no calibration is needed, as all calibration data is stored and processed in the sensor itself.

 Open the catalog to page 1
EM5010A Environment Monitor-2

wekomm One feature, rarely seen in this kind of instruments is the very capable limit surveillance function, the EM5010A offers. Basically you can chose between two modes of checking. One mode is just recording, if the value monitored exceeds it’s allowed limits. This event then will trigger some configurable actions like sending an email or activating a contact (option). In addition, a warning sign is displayed even if the value has already returned within limits. By this way you will never miss any violation of limits. This kind of warning needs to be reset manually while all limit violations...

 Open the catalog to page 2
EM5010A Environment Monitor-3

Data management All data, measured by the connected sensors are permanently recorded locally. All sensors are queried in a defined interval (5 sec shortest) and will deliver their respective measurement data. will not even be selectable for display. Whereas all GPS data is being recorded together with the measured data. This provides a location information for each set of measurements. The EM5010A provides up to four display areas (slots), where measurement data can be shown. That display I intended to give a good overview about the most critical data being measured. Even alarms will be executed,...

 Open the catalog to page 3
EM5010A Environment Monitor-4

Available Sensors The range of sensors for the EM5010A is under continuous development and will be expanded in the future. A the date of editing this document the following sensors are available: S5010A Particulate Matter (1.0, 2.5,4.5, 10), VOC, Humidity, Temperature S5100A Eight digital inputs Typ. accuracy rel. humidity Measurement range Response time Temperature Typ. accuracy temperature Measurement range Response time Dimensions Weight Cable Length length: 13cm, Diameter 12mm 0.03 kg approx. 1.5m length: 13cm, Diameter 12mm 0.03 kg approx. 1.5m abs. accuracy pressure Measurement range Response...

 Open the catalog to page 4
EM5010A Environment Monitor-5

we Particulate Matter accuracy ± 10% Each Particle Size measurement is represented as a separate sensor and is therefore Measured simultaneously Temperature Typ. accuracy temperature 0.45 °C Measurement range -10 to +50°C Output Signal Measurement range Response Time Sensor to Sensor deviation Detection Limit Settle Time Internal Humidity comp. Dimensions Weight Cable Length < 0.05 ppm of ethanol equivalents or < 10% of concentration setpoint, whichever is larger 1h yes S5090A Specifications Supported Systems Supported Channels Dimensions Weight Cable Length GPS, GLONASS, GALILEO, QZSS 210 PRN-Channels...

 Open the catalog to page 5

All EVOMESURE catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.