Evotube U

Evotube U

Evotube U

Product catalog summary
Introduction
The Evotube U is a heat exchanger module designed primarily for Clean-In-Place (CIP) systems, but it is also suitable for heating and cooling process water and non-aseptic product applications. It has been part of Krones lines for years and is now available as a compact module.

Key Features
  • Main application: CIP systems, with additional uses in heating and cooling process water.
  • Efficient heat transfer due to a large heat exchanger surface.
  • Compact dimensions with a module length of 2,097 mm.
  • Thermal length compensation via sliding joint and internally mounted tube bundle.
  • Hygienic design for easy maintenance.

Technical Specifications
  • Pressure resistance: 16 bar inside, 10 bar outside.
  • Maximum temperature range: 185 °C.
  • Material: 1.4404 with a surface condition of Ra 0.8 inside.
  • Pressure equipment directive: AD2000.
  • Nominal diameters range from DN40 to DN100.

Customization and Support
Evoguard offers tailored heat exchanger solutions with individual configurations and rheological product characterization in the Krones laboratory. Experienced specialists provide advice using a database of over 2,000 product data.

Heat Exchanger Portfolio
The document provides a table of module types with specifications such as rated flow rate, module length, heat exchanger surface, differential temperature on the primary side, and heat transfer performance.

Module Nomenclature
The nomenclature includes details like the diameter of the exterior pipe, number of interior pipes, outer diameter, and wall thickness of interior pipes.

Benefits
  • Flexible application with robust jacket pipe for safe installation.
  • Safe operation with leakproof sliding joint design.
  • Efficient heat transfer with compact module dimensions.
  • Safe cleaning due to hygienic design with reduced dead space.

Additional Offerings
The Krones Group also provides units for product deaeration, heating, product mixing, process water sterilization, and CIP/SIP systems.

Product Range Overview
The document lists additional products such as aseptic valves, hygienic valves, feedback controlling, sampling, ESL valves, safeguarding, tank safety systems, and centrifugal pumps.
See more

Catalog excerpts

Evotube U-1

Evotube U Heat exchanger systems especially for CIP systems

 Open the catalog to page 1
Evotube U-2

Heat exchanger module for CIP processes The Evotube heat exchanger has been integrated in Krones lines for many years and has been available on the market as individual components since 2020. Now there is a new, compact module that is ideal for use primarily in CIP systems. It is also suitable for heating and cooling process water and for non-aseptic product applications. At a glance − Main field of application: CIP systems  but also for heating and cooling process water and for nonaseptic product applications − Efficient heat transfer due to large heat exchanger surface − Still compact dimensions...

 Open the catalog to page 2
Evotube U-3

Pressure resistance: 16 bar inside/10 bar outside Max. temperature range: 185 °C Material: 1.4404 Surface condition: Ra 0.8 inside Pressure equipment directive: AD2000 Nominal diameters: DN40 to DN100 Length per mod

 Open the catalog to page 3
Evotube U-4

The right heat exchanger for every application Evoguard is the ideal partner when it comes to the selection of a tailor-made heat exchanger: − Clarification of requirements − Individual configuration of the heat exchanger, especially customised to suit your requirements − Rheological product characterization in the Krones laboratory possible − Advice from experienced specialists which can access considerable databases with more than 2,000 produ

 Open the catalog to page 4
Evotube U-5

Heat exchanger portfolio Module type* U Rated flow rate with 2 m/s (m³/h) Heat exchanger surface (m²) Differential temp. primary side (°K) Heat transfer performance (kW) All values based on: Primary medium: Caustic (4 %), heating to 85 °C Secondary medium: Saturated steam, 3 bar at 144 °C * Nomenclature: see next

 Open the catalog to page 5
Evotube U-6

Explanation of the module nomenclature Example: 110.3-28*14/1 U Diameter exterior pipe (mm) Number of interior pipes Outer diameter of interior pipes (mm) Wall thickness of interior pipes (mm) U = universal

 Open the catalog to page 6
Evotube U-7

Benefits to you Flexible application The robust jacket pipe enables safe installation in every installation position. Safe operation The sliding joint was designed according to the Evoguard valve technology and permits leakproof operation. Efficient heat transfer with compact dimensions With a length of 2,097 mm, the dimensions of every module are compact. The heat exchanger surface, on the other hand, increases depending on the size, ensuring effective heat transfer. Safe cleaning Thanks to a design with reduced dead space in hygienic design, all product contacting surfaces are easy to clean....

 Open the catalog to page 7
Evotube U-8

Overview of our product range Tank safety systems Centrifugal pumps Heat exchanger Hygienic valves Aseptic valves

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.