Group: EVIDENT
Catalog excerpts
EVIDENT Microscope Digital Camera Intelligent Imaging for an Improved Workflow NEW
Open the catalog to page 1Intuitive Workflow Enhancements for Easy Operation The DP74 color fluorescence camera captures realistic, high-quality images and has features that enable users to make their observations easily. With a wide field of view, operators can capture images of more of their sample, quickly. In applications like histology, the DP74 camera faithfully reproduces colors to render natural images of your specimen. The camera displays a realistic image, so what appears on the monitor looks the same as what users see looking through the microscope’s eyepieces. Users can remain comfortable during their...
Open the catalog to page 2Fast, high sensitivity, and superior quality image with the latest CMOS technology. High Sensitivity Superior Image Quality Intelligent Assist Smooth Observation Smart camera navigation for comfortable observation. Observation Image
Open the catalog to page 3Capture High-Quality Images Quickly and Easily Full HD Images of Live Specimens are Fast and Simple to Acquire Obtain high-quality images of live specimens higher than FullHD resolution (2.3 million native pixels). The DP74 camera delivers images at a full 60 frames per second. The high frame rate enables users to make observations quickly and easily and capture fast movements in the specimen. The DP74's global shutter eliminates the live image distortion frequently caused by rolling shutter CMOSs. DP74 Smooth live images make it easy locate an object's position. Live image is not updated...
Open the catalog to page 4Capture Fine Details at Low Magnifications The DP74 camera provides high resolution at low magnification. The camera’s pixel shifting technology provides sub-pixel information, delivering the equivalent of 20.7 million pixels in a high-resolution image. The 3-CMOS mode makes each pixel's information as accurate as three chip cameras. This provides more detail, creating highdefinition images with fine color reproduction without increasing the file size. Without shift With shift Vivid Fluorescence Images with Reduced Noise Because the CMOS sensor is cooled, it enables sharp fluorescence...
Open the catalog to page 5Enhanced Efficiency and Comfort Easily know the location of interest with the Position Navigator The position navigator adds convenience to the operator’s workflow because it creates a map to help users keep track of their location within the specimen; this is especially useful when making observations at high magnification. This is achieved without the need for a motorized or encoded stage. The low-magnification map of the sample containing all of the pertinent location information can be stored along with the high-magnification observation image, making it convenient for record keeping or...
Open the catalog to page 6Focus on Dim Fluorescent Signals with Intelligently Designed Noise Reduction The multi-frame live noise reduction (FNR) feature makes it possible to capture low-noise, high-speed images of live specimens in real time. Olympus’ noise reduction technology enables users to obtain sharp fluorescence images, even in weak fluorescence. The FNR feature takes multiple pictures of an image and then removes the random background noise. The camera is intelligent enough to be able to stop the FNR only when the stage is moving, making it easier to scan your specimen and focus during fluorescence...
Open the catalog to page 7* Pixel shift and 3-CMOS mode images cannot be acquired in a 32-bit OS environment. *2 Frame rate may decrease depending on the condition of your PC and/or software. *3 Monitor designed to meet Adobe RGB is required. *4 Not available in the combination of cellSens Entry and DP2-TWAIN. *5 In order for the maximum full-size live frame rate to be achieved, both dual-channel and PC10600 or greater RAM is required. *6 Do not install large boards, like graphic boards, in the adjacent slot on the fan side of the DP74 camera's PCIe board. Please contact your nearest Olympus dealer for more...
Open the catalog to page 8All Evident - Olympus Scientific Solutions catalogs and technical brochures
-
39DL PLUS
12 Pages
-
COBRA® Manual Weld Scanner
2 Pages
-
Rotating Billet Inspection
5 Pages
-
Phased Array Probes and Wedges
17 Pages
-
Spotweld Transducers
2 Pages
-
72DL PLUS™
8 Pages
-
Magna-Mike™ 8600
4 Pages
-
DC1–DC5
5 Pages
-
45MG
12 Pages
-
35 RDC
2 Pages
-
OmniScan MX ECA
2 Pages
-
NORTEC™ Scanners
2 Pages
-
OmniScan® X3 64
8 Pages
-
IPLEX GX/GT
8 Pages
-
IPLEX Long Scope
4 Pages
-
RVI General Overview
12 Pages
-
IPLEX TX
4 Pages
-
IPLEX G Lite
8 Pages
-
IPLEX GAir
8 Pages
-
IPLEX NX
12 Pages
-
Microscope Component Solutions
12 Pages
-
MXPLFLN Series
2 Pages
-
OLYMPUS Stream
16 Pages
-
LC35
4 Pages
-
DP28
8 Pages
-
SZX7
16 Pages
-
SZ61 SZ51 Brochure
24 Pages
-
SZX16 - SZX10
24 Pages
-
MX63/MX63L
20 Pages
-
GX53 Brochure
20 Pages
-
BXC Series Brochure
4 Pages
-
BX53M - BXFM Brochure
28 Pages
-
CIX100
16 Pages
-
STM7 Series
24 Pages
-
LEXT OLS5000
42 Pages
-
Vanta Overview
8 Pages
-
Vanta™ Handheld XRF Analyzer
8 Pages
-
Vanta™ iX Systems
4 Pages
-
Vanta™ iX Brochure
4 Pages
-
NORTEC 600
7 Pages
-
OmniScan X3 64 Brochure
8 Pages
-
OmniScan® X3 Brochure
8 Pages
-
Camera Overview
12 Pages
-
DSX1000 Brochure
40 Pages
-
72DL PLUS
8 Pages
-
Industrial Scanners brochure
36 Pages
-
IPLEX G LITE-W brochure
4 Pages
-
SZX-AR1
12 Pages
-
PRECiV 1.2 Brochure
20 Pages
-
Vanta GX Brochure
4 Pages
-
27MG
4 Pages
-
BondMaster 600
8 Pages
-
EdgeFORM™
2 Pages
-
EX Series Instruments
4 Pages
-
OpenView SDK
3 Pages
-
Mini_Wheel_Encoder
2 Pages
-
OmniScan MX
12 Pages