Ultrasonic Thickness Gage 45MG Ultrasonic Thickness Gage Simple, Rugged, and Reliable Operation Shown with optional waveform Color transflective QVGA display Dual element corrosion gaging Precision thickness measurements Rugged, designed for
Open the catalog to page 145MG Ultrasonic Thickness Gage Simple, Rugged, and Reliable Operation The 45MG advanced ultrasonic thickness gage is packed with standard measurement features and software options. This unique instrument is compatible with the complete range of Olympus dual element and single element thickness gage transducers, making it an all-in-one solution for virtually every thickness gage application. Built for Tough Environments • Rugged, designed for IP67 • Explosive atmosphere: tested using MIL-STD-810G, Method 511.5, Procedure I • Vibration tested using MIL-STD-810G, Method 514.6, Procedure I •...
Open the catalog to page 2Standard Features In its basic configuration the 45MG instrument is a simple and straightforward gage that requires minimal operator training to tackle most common thickness gaging applications. With additional optional software options and transducers, however, the 45MG thickness gage can become significantly more advanced and take on applications well beyond that of a typical entry-level gage. Furthermore, most options are available individually at the time of purchase or can be added in the future as your needs change. • Compatible with the full line of Olympus dual element transducers...
Open the catalog to page 3Thickness Measurements on Internally Corroded Metals Using Dual Element Transducers One of the major applications of the 45MG is measuring the remaining thickness of pipes, tubes, tanks, pressure vessels, ship hulls, and other structures affected by corrosion or erosion. Dual element transducers are most commonly used for these applications. • Automatic Probe Recognition for standard D79X series dual element transducers • Calibration doubling warning when echo doubling may occur during calibration • The echo-to-echo / THRU-COAT® technology option enables measurements on painted and coated...
Open the catalog to page 4Echo-to-Echo / THRU-COAT® Option Echo-to-Echo THRU-COAT Technology The gage displays the true metal thickness and ignores the thickness of the coating layer, using multiple back-wall echoes: Uses a single back-wall echo to measure true metal thickness. You can display the metal and coating thicknesses, each adjusted for their correct material sound velocities. There is no need to remove paint and coatings from surfaces. THRU‑COAT measurements use the D7906-SM, D7906‑RM, and D7908 dual element transducers. • Auto echo-to-echo • anual echo-to-echo (with A-scan option only) that enables: M --...
Open the catalog to page 5* Thickness range dependent on material, transducer type, surface conditions, and temperature. + Stainless steel cable available; consult Olympus for details. Full range may require Gain adjustment. ++ Not certified to EN15317; the MTD705 is issued a TP103 test ** Maximum temperature with intermittent contact only. certificates in accordance with ASTM E1065. +++ Transducers used with THRU-COAT® technology.
Open the catalog to page 6Optional Data Logger and PC Interface The 45MG thickness gage has a full-featured internal bidirectional alphanumeric data logger that is designed to easily store and transfer thickness readings and waveform data. The data logger option includes the GageView™ interface program. Data Logger Option • Internal memory of 475,000 thickness readings or 20,000 waveforms with thickness readings • 32 character file name • 20 character ID# (TML#) • 6 file formats: Incremental, sequential, sequential with custom point, 2-D grid, boiler, and manual (from PC) GageView • Internal and removeable microSD...
Open the catalog to page 7Thickness Measurements on Plastics, Metals, Composites, Glass, Rubber, and Ceramics Using Single Element Transducers Single element transducers enable you to make accurate thickness measurements on metals, plastics, composites, glass, ceramics, and other materials. These transducers are available in a wide range of frequencies, diameters, and connector styles. In order to use a single element transducer with the 45MG gage, you must purchase either the Single Element software or the High Penetration software option. • Single Element software option can display measurements up to 0.001 mm...
Open the catalog to page 8Application Setup Recall Application Setup Recall simplifies making thickness measurements. Select any of the stored transducers and the 45MG gage recalls all relevant internal transducer parameters. Stored Standard Setups The 45MG gage includes 21 standard single element transducer setups for the most common applications. These default transducer setups can be used on wide variety of thickness applications. Material Sound Velocity Measurements The 45MG gage has the capability to make material sound velocity measurements. This standard feature is useful in applications where the speed of...
Open the catalog to page 9RBS-1 Immersion Tank The RBS-1 immersion tank is designed to simplify ultrasonic thickness measurements using immersion techniques.
Open the catalog to page 10Delay Line Transducers Microscan delay line transducers provide excellent performance on very thin materials, at elevated temperatures, or with applications that require a high degree of thickness resolution. * Exact range depends on material sound velocity, transducer frequency, part geometry, and surface condition. Replaceable Delay Lines Delay lines function as a protective buffer between the surface of the test piece and the transducer element. Additional Products Couplants Liquid couplant is almost always necessary to provide acoustic coupling between the transducer and the test piece....
Open the catalog to page 11Standard Package • 45MG digital ultrasonic thickness gage • AA alkaline batteries • 2-step test block and couplant • USB cable • User's manual on CD • Measurement features: Min./Max. mode, two alarm modes, Differential mode, B-scan, Reduction Rate, Programmable Lock Software Options • 45MG-SE (U8147022): Single Element option to use single element transducers with frequency range of 2.25 MHz to 30 MHz. • 45MG-HP (U8147023): Single Element High Penetration option to use single element transducers with frequency range of 0.5 MHz to 30 MHZ. • 45MG-EETC (U8147021): Echo-to-Echo and THRU-COAT® •...
Open the catalog to page 12All Evident - Olympus Scientific Solutions catalogs and technical brochures
-
39DL PLUS
12 Pages
-
COBRA® Manual Weld Scanner
2 Pages
-
Rotating Billet Inspection
5 Pages
-
Phased Array Probes and Wedges
17 Pages
-
Spotweld Transducers
2 Pages
-
72DL PLUS™
8 Pages
-
Magna-Mike™ 8600
4 Pages
-
DC1–DC5
5 Pages
-
35 RDC
2 Pages
-
OmniScan MX ECA
2 Pages
-
NORTEC™ Scanners
2 Pages
-
OmniScan® X3 64
8 Pages
-
IPLEX GX/GT
8 Pages
-
IPLEX Long Scope
4 Pages
-
RVI General Overview
12 Pages
-
IPLEX TX
4 Pages
-
IPLEX G Lite
8 Pages
-
IPLEX GAir
8 Pages
-
IPLEX NX
12 Pages
-
Microscope Component Solutions
12 Pages
-
MXPLFLN Series
2 Pages
-
OLYMPUS Stream
16 Pages
-
LC35
4 Pages
-
DP74
8 Pages
-
DP28
8 Pages
-
SZX7
16 Pages
-
SZ61 SZ51 Brochure
24 Pages
-
SZX16 - SZX10
24 Pages
-
MX63/MX63L
20 Pages
-
GX53 Brochure
20 Pages
-
BXC Series Brochure
4 Pages
-
BX53M - BXFM Brochure
28 Pages
-
CIX100
16 Pages
-
STM7 Series
24 Pages
-
LEXT OLS5000
42 Pages
-
Vanta Overview
8 Pages
-
Vanta™ Handheld XRF Analyzer
8 Pages
-
Vanta™ iX Systems
4 Pages
-
Vanta™ iX Brochure
4 Pages
-
NORTEC 600
7 Pages
-
OmniScan X3 64 Brochure
8 Pages
-
OmniScan® X3 Brochure
8 Pages
-
Camera Overview
12 Pages
-
DSX1000 Brochure
40 Pages
-
72DL PLUS
8 Pages
-
Industrial Scanners brochure
36 Pages
-
IPLEX G LITE-W brochure
4 Pages
-
SZX-AR1
12 Pages
-
PRECiV 1.2 Brochure
20 Pages
-
Vanta GX Brochure
4 Pages
-
27MG
4 Pages
-
BondMaster 600
8 Pages
-
EdgeFORM™
2 Pages
-
EX Series Instruments
4 Pages
-
OpenView SDK
3 Pages
-
Mini_Wheel_Encoder
2 Pages
-
OmniScan MX
12 Pages